Error Code Description
460A 525E CUoD capacity card fault
460A 525F CUoD capacity card fault
460A 527A CUoD capacity card fault
460A 527C CUoD capacity card fault
460B 248B I/O subsystem and wire tests detected fault in
operator panel
460B 25C0 I/O subsystem and wire tests detected fault in
system backplane
460B 25C1 I/O subsystem and wire tests detected fault in
1.0 GHz clock card
460B 2738 I/O subsystem and wire tests detected fault in
I/O book 1, 3, or 4
460B 273C I/O subsystem and wire tests detected fault in
primary I/O book - Slot 0
460B 273D I/O subsystem and processor subsystem tests
detected fault in primary I/O book - Slot 0
460B 2776 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
Action/
Possible Failing FRU
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
Operator panel
Location: U1.17-L1
System backplane
Location: U1.18-P1
Clock card
Location: U1.18-P1-X5
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
Primary I/O book - Slot 0
Location: U1.18-P1-H2
Primary I/O book - Slot 0
Location: U1.18-P1-H2
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
Chapter 5. Error Code to FRU Index
699