IBM pSeries 690 Service Manual page 259

Hide thumbs Also See for pSeries 690:
Table of Contents

Advertisement

Step 152f-9
Turn on the power.
Step 152f-10
Did the system stop with the same error code as recorded in "Step 152f-1" on page 238?
Yes
The book just reinserted is defective. Replace it. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
No
Go to "Step 152f-11".
Step 152f-11
Have all the books listed in "Step 152f-4" on page 238 been reinserted?
Yes
The symptom has changed. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
No
Go to "Step 152f-8" on page 238.
Step 152f-12
Turn off the power.
Examine the amber logic-power LEDs of all installed processor subsystem DCAs.
Step 152f-13
Are all amber logic-power LEDs of all installed processor subsystem DCAs off?
Yes
Go to "Step 152f-14".
No
Call for support.
Step 152f-14
Pull out the following books about 25 mm (1 inch), if present:
v Memory book 4, at location U1.18-P1-M4
v Memory book 5, at location U1.18-P1-M8
v Memory book 6, at location U1.18-P1-M5
v Memory book 7, at location U1.18-P1-M1
Step 152f-15
Turn on the power.
Chapter 3. Maintenance Analysis Procedures
239

Advertisement

Table of Contents
loading

Table of Contents