IBM pSeries 690 Service Manual page 202

Hide thumbs Also See for pSeries 690:
Table of Contents

Advertisement

Step 1322-9
Is the FRU list identical (same FRUs, same number of FRUs, and same order of FRUs) to the FRU
list of the error code recorded in "Step 1322-1" on page 181?
No
Go to "Step 1322-10".
Yes
Go to "Step 1322-11".
Step 1322-10
The FRU list is different.
Is the FRU you replaced and recorded in "Step 1322-1" on page 181 in the list of FRUs for this
service action event?
No
Go to "Step 1322-33" on page 184.
Note: There are service action events that will remain open when you leave this MAP. Further
service actions may be required to complete the repair.
Yes
Go to "Step 1322-11".
Step 1322-11
Examine the details of this service action event, and record the partition(s) involved in this service action
event for use in a later step.
Step 1322-12
Is the error code associated with this service action event of the form A11-xxx or A01-xxx?
No
Go to "Step 1322-17" on page 183.
Yes
Go to "Step 1322-13".
Step 1322-13
Have you begun a list of "Axx" partitions from prior service action events that you processed in
this MAP?
No
Go to "Step 1322-14".
Yes
Go to "Step 1322-15".
Step 1322-14
Begin a new list of "Axx" partitions by copying the list of partitions obtained in "Step 1322-11". Go to "Step
1322-16" on page 183.
Step 1322-15
Add the partition list obtained in "Step 1322-11" to the existing list of "Axx" partitions obtained from
processing previous service action events in this MAP.
182
Eserver pSeries 690 Service Guide