MAP 1522: UEPO Switch On The BPC Is In The Bypass Position

Step 1522-1
Check the UEPO Switch on the BPC on the BPA that is exhibiting the failure.
Is the switch in the NORMAL position?
NO
Set UEPO switch on the BPC to the NORMAL position and go to "Step 1522-2".
YES
Go to "Step 1522-2".
Step 1522-2
Press the Service Complete button.
Is error code 101A FE16 or 101B FE16 displayed?
The problem has already been corrected. Go to "MAP 0410: Repair Checkout" in the RS/6000
NO
and Eserver pSeries Diagnostic Information for Multiple Bus Systems.
YES
Replace the BPC on the side that is exhibiting the failure. Follow all the steps in the "Bulk Power
Controller (BPC)" on page 830. Go to "Step 1522-3".
Step 1522-3
If not done already, press the service complete button.
Is error code 101A FE16 or 101B FE16 displayed?
The problem has been corrected. Go to "MAP 0410: Repair Checkout" in the RS/6000 and
NO
Eserver pSeries Diagnostic Information for Multiple Bus Systems. This ends the procedure.
YES
Call for support. This ends the procedure.