IBM pSeries 690 Service Manual page 461

Hide thumbs Also See for pSeries 690:
Table of Contents

Advertisement

Error Code Description
1021 CDC6 A power short has been detected in the DASD
subsystem in an I/O drawer.
1021 F4x6 Hardware configuration does not support
N-mode power.
1021 F516 An N+1 boundary (DCA or fan) has dropped to
N-mode status in the first I/O subsystem in the
secondary rack, location: U2.1.
1021 F526 An N+1 boundary (DCA or fan) has dropped to
N-mode status in the first I/O subsystem in the
secondary rack, location: U2.1.
1021 xx11 First I/O subsystem in second rack, DCA-1
1021 xx13 Seeprom fault on DCA-1 in first I/O subsystem
secondary rack
1021 xx15 First I/O subsystem in second rack, DCA-1,
cable fault
1021 xx17 Problem with fan 1 and fan 3 in first I/O
subsystem in second rack
1021 xx21 First I/O subsystem in second rack, DCA-2
1021 xx23 Seeprom fault on DCA-2 in first I/O subsystem
secondary rack
1021 xx25 First I/O subsystem in second rack, DCA-2,
cable fault
1021 xx27 Problem with fan 2 and fan 4 in first I/O
subsystem in second rack
1021 xx31 First I/O subsystem in secondary rack I/O
subsystem backplane 1 fault
Action/
Possible Failing FRU
Go to "MAP 1520: Power" on page 190.
Call Service Support
This is normally an informational message. It
should be accompanied by other error codes
that more precisely indicate where the failure is.
Examine the service processor error log. If there
are no other power-related error codes (in the
time frame in which this code was generated) in
the service processor error log, the FRU
indicated with this error code, if any, should be
replaced.
This is normally an informational message. It
should be accompanied by other error codes
that more precisely indicate where the failure is.
Examine the service processor error log. If there
are no other power-related error codes (in the
time frame in which this code was generated) in
the service processor error log, the FRU
indicated with this error code, if any, should be
replaced.
U2.1-V1
U2.1-V1
Go to "MAP 1520: Power" on page 190 with
these pairs of location codes:
1. U2.1-V1/Q1 and U1.35-P2-X2/Q1
2. U2.1-V1/Q2 and U1.35-P1-X2/Q1
1. DCA-1
Location U2.1–V1
2. Fan 1,
Location U2.1–F1
3. Fan 3,
Location U2.1–F3
U2.1-V2
U2.1-V2
Go to "MAP 1520: Power" on page 190 with
these pairs of location codes:
1. U2.1-V2/Q1 and U1.35-P2-X2/Q2
2. U2.1-V2/Q2 and U1.35-P1-X2/Q2
1. DCA-2
Location U2.1–V2
2. Fan 2,
Location U2.1–F2
3. Fan 4,
Location U2.1–F4
U2.1-P1