Step 152k-31
Did the system stop with the same error code as recorded in "Step 152k-1" on page 275?
Yes
The card just reinserted is defective. Replace it. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
No
Go to "Step 152k-32".
Step 152k-32
Have all the cards listed in "Step 152k-25" on page 278 been reinserted?
Yes
The symptom has changed. This ends the procedure.
Return the system to its original configuration.
Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver pSeries Diagnostic Information
for Multiple Bus Systems.
No
Go to "Step 152k-29" on page 278.
Step 152k-33
Turn off the power.
Examine the green "power good out" LEDs of both I/O subsystem DCAs.
Step 152k-34
Are all the green "power good out" LEDs of both I/O subsystem DCAs off?
Yes
Go to "Step 152k-35".
No
Call for support.
Step 152k-35
Remove the following adapter cards, if present, from the I/O subsystem. Record the adapter locations:
v Adapter card at P2-I6
v Adapter card at P2-I7
v Adapter card at P2-I8
v Adapter card at P2-I9
v Adapter card at P2-I10
Step 152k-36
Turn on the power.
Step 152k-37
Did the system stop with the same error code as recorded in "Step 152k-1" on page 275?
Yes
Go to "Step 152k-43" on page 280.
No
Go to "Step 152k-38".
Step 152k-38
One of the cards just removed is defective.
Turn off the power.
Make sure all the green "power good out" LEDs of both I/O subsystem DCAs are off.
Chapter 3. Maintenance Analysis Procedures
279