IBM pSeries 690 Service Manual page 714

Hide thumbs Also See for pSeries 690:
Table of Contents

Advertisement

Error Code Description
4606 525E CUoD capacity card fault
4606 525F CUoD capacity card fault
4606 527A CUoD capacity card fault
4606 527C CUoD capacity card fault
4607 248B I/O subsystem and bus tests detected fault in
operator panel
4607 25C0 I/O subsystem and bus tests detected fault in
system backplane
4607 25C1 I/O subsystem and bus tests detected fault in
1.0 GHz clock card
4607 2738 I/O subsystem and bus tests detected fault in
I/O book 1, 3, or 4
4607 273C I/O subsystem and bus tests detected fault in
primary I/O book - Slot 0
4607 273D I/O subsystem and processor subsystem tests
detected fault in primary I/O book - Slot 0
4607 2776 I/O subsystem and processor subsystem tests
detected fault in I/O book 1, 3, or 4
694
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
1. Verify that the system firmware is RH021114
or later. CUoD is not supported by the
earlier firmware levels.
2. Replace the CUoD capacity card,
location: U1.18-P1-H2.2, then ask the
customer to reenter the CUoD activation
keys.
Operator panel
Location: U1.17-L1
System backplane
Location: U1.18-P1
Clock card
Location: U1.18-P1-X5
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.
Primary I/O book - Slot 0
Location: U1.18-P1-H2
Primary I/O book - Slot 0
Location: U1.18-P1-H2
1. If word 13 is CFF1 xxxx, a configuration
problem exists. Ensure that the number of
MCMs is consistent with the number of I/O
books.
2. Replace I/O book 1, 3, or 4 at location
specified in error code.