Runtime Error Logging Screen - QUANTA STRATOS S200 Series S200-X12TS Technical Manual

2-socket general purpose 1u server
Table of Contents

Advertisement

BIOS

Runtime Error Logging Screen

Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
Main
Advanced
Chipset
Server Mgmt
Boot Security
Runtime Error Logging Support
[Enabled]
ECC Error Logging
[Enabled]
Memory Corr. Error Threshold
10
QPI Error Logging
[Enabled]
PCI Error Logging Support
[Enabled]
IIO Error Logging
[Enabled]
NMI on Critical Error
[Enabled]
Version 2.14.1219 - Copyright (C) 2011 American Megatrends, Inc.
Runtime Error Logging Screen
Runtime Error Logging Fields
S
I
O
ETUP
TEM
PTIONS
Runtime
Enable/Disable
[Disabled]
Error Log-
Runtime Error Log-
[Enabled]
ging Support
ging Support.
Save & Exit
Enable/Disable Runtime
Error Logging Support.
: Select Screen
: Select Item
Enter: Select
+/-: Change Opt.
F1: Genenal Help
F8: Previous Values
F9: Optimized Defaults
F10: Save & Exit
ESC: Exit
H
T
C
ELP
EXT
OMMENTS
Runtime Error Logging Fields (Continued)
S
I
O
ETUP
TEM
PTIONS
[Disabled]
ECC Error
Logging
[Enabled]
Memory
Corr. Error
Threshold
[Disabled]
QPI Error
Logging
[Enabled]
PCI Error
[Disabled]
Logging
[Enabled]
Support
IIO Error
[Disabled]
Logging
[Enabled]
NMI on Criti-
[Disabled]
cal Error
[Enabled]
3-16
A
DVANCED
H
T
C
ELP
EXT
OMMENTS
Enable/Disable
ECC Error Log-
ging.
Enter the Memory
This can be set to
Correctable Error
a value between 1
Threshold value
to 15. Default is 10.
Enable/Disable
QPI Error Logging
Enable/Disable
PCI Error Logging
Support
Enable/Disable IIO
Error Logging
Enable/Disable
NMI generation on
fatal or uncorrect-
able error