Table of Contents

Advertisement

User Manual系统安装
QSSC-980 Server服务器
系统安装手册
系统安装
系统安装
服务器
服务器
服务器
手册
手册
手册

Advertisement

Table of Contents
loading

Summary of Contents for QUANTA QSSC-980

  • Page 1 系统安装 系统安装 系统安装手册 手册 手册 手册 User Manual系统安装 服务器 服务器 服务器 QSSC-980 Server服务器...
  • Page 3: Regional Emc Compliance Information

    Preface Regional EMC Compliance Information FCC Verification Notice (USA only) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Class A This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules.
  • Page 4 Preface China RoHS Declaration Table 有毒有害物质或元素 有毒有害物质或元素 (Hazardous Substance) 有毒有害物质或元素 有毒有害物质或元素 部件名称 部件名称 部件名称 部件名称 (Component Name) 铅 铅 铅 铅 汞 汞 汞 汞 镉 镉 镉 镉 六价铬 六价铬 多溴联苯 多溴联苯 多溴二苯醚 多溴二苯醚 六价铬 六价铬 多溴联苯 多溴联苯 多溴二苯醚 多溴二苯醚...
  • Page 5 Preface 警示 警示: : : : 安全指示說明 安全指示說明 警示 警示 安全指示說明 安全指示說明 請務必遵守下列安全指導說明,以確保您的人身安全,避免可能對系統和工作環境造成損害。 警告 警告 警告 警告: : : : 您系統中的電源供應器可能會釋放出高電壓或電能 您系統中的電源供應器可能會釋放出高電壓或電能 您系統中的電源供應器可能會釋放出高電壓或電能, , , , 可能會對您的身體產生危害 您系統中的電源供應器可能會釋放出高電壓或電能 可能會對您的身體產生危害 可能會對您的身體產生危害。 。 。 。 除非另有指示 可能會對您的身體產生危害 除非另有指示 除非另有指示 除非另有指示, , , , 否 否 否 否 則僅限受過專業訓練之維修技師有權卸除機殼及拆裝任何系統內部的元件。...
  • Page 6 Preface 請特別注意延長線及其多孔電源插座盒的功率規格。請注意,所有產品接到延長線或多孔電源插座盒的總 電流不得超過延長線或多孔電源插座盒本身電流上限的百分之八十。 為避免您的系統供電發生突波的不穩定現象,請使用穩壓器、電路調節器或不斷電電源供應器(UPS) 請小心配置系統接線和電源線;務必將接線整理妥當以免有人不慎踩到或絆倒。請確保沒有任何東西壓在 接線上。 請勿任意改造電源線或插頭。如需修改您的場地配線,請洽詢有執照的專業電匠或您當地的電力公司。請 務必遵循您當地/全國的配線法規。 為避免損壞主機板,關閉系統電源後請再等待五秒,之後再拆下系統主機板上的元件或拔除系統周邊裝 置。 處理電池時請特別小心。請勿將電池拆開、壓碎、刺穿、使其外部連接短路、丟棄到火裡或水中,或者是 使其暴露在高於攝氏 60 度(華氏 140 度) 環境下。請勿自行嘗試拆開或修復電池;務必更換產品指定使用 的電池類型。 如果您的系統有隨附熱插拔電源供應器,請特別注意下列有關接上或拔除接線的指示說明: 接上電源線前,請先裝好電源供應器。 移除電源供應器前請先拔除電源線。 如果系統有多個供電來源,請拔除所有電源供應器的電源接線來切斷系統供電。 搬動產品請格外小心;請確認所有腳輪和/或支腳有牢牢地接在系統上。請避免突然停下或在凹凸的表面 上搬運產品。 根據本產品德國工作場所法則第§2 條有關視訊顯示裝置的規定,本產品不適於搭配視訊顯示裝置使用。 安全性: : : : 萬一系統受潮 安全性 萬一系統受潮 安全性 安全性 萬一系統受潮 萬一系統受潮 備註 備註: : : : 在開始執行下列步驟前 備註...
  • Page 7 Preface 安全性: : : : 架設系統機架 安全性 架設系統機架 安全性 安全性 架設系統機架 架設系統機架 請仔細閱讀下列注意事項,以確保機架的穩定性和安全。另請參閱系統和機架隨附的機架安裝說明文件,閱讀其中 的特別注意聲明和安裝程序。 系統是指放在機架中的元件。因此,「元件」可以代表任何系統及各種周邊裝置,或者是支援硬體。 警告: : : : 將系統安裝到機架中前 警告 將系統安裝到機架中前, , , , 請先裝好獨立 請先裝好獨立(單一 單一) 機架的正面和側邊支腳 機架的正面和側邊支腳, , , , 或者是裝好 或者是裝好連接機架的正面支 連接機架的正面支 警告 警告 將系統安裝到機架中前 將系統安裝到機架中前 請先裝好獨立...
  • Page 8 Preface 唯有專業的服務技術人員才能修復雷射裝置。 安全性 安全性: : : : 處理系統內部 安全性 安全性 處理系統內部 處理系統內部 處理系統內部 卸除系統外殼前,請先依序執行下列步驟。 警告: 除非文件內另有指示說明,否則僅限受過專業訓練之維修技師才能卸除系統機殼及拆裝任何系統內部 的元件。 注意: 為避免損壞主機板,關閉系統電源後請再等待五秒,之後再拆下系統主機板上的元件或拔除周邊裝置。 關閉系統和所有裝置的電源。 為防止您身上的靜電破壞系統內部元件,請碰觸機盒上未上漆的金屬表面以達接地效果。 工作時,建議您不時碰觸機盒上未上漆的金屬表面,以將可能傷害內部元件的靜電導引至地端。 拔除系統及裝置的電源。為降低人身受傷或觸電的風險,請拔除系統所有的電信線路。 並請適時記下這些安全性指導原則: 拔除電纜時,請握住插頭或耐扭式電源線環,勿直接拉扯電纜。有些電纜的插頭上附有鎖片,如果您要拔 除這種類型的電纜,拔除前請先按壓鎖片。拔除插頭時,請將插頭整齊排列、間隔均等,以避刷折彎插頭 插腳。此外,接上電纜前也請確保兩個插頭方向正確且對齊。 請小心處理元件與設備用卡。請勿碰觸卡上的元件或接點。請拿著卡的邊緣或金屬固定架。請拿著元件 ( 如微處理器晶片) 的邊緣而非其插腳。 安全性 安全性: : : : 避免靜電釋放 安全性 安全性 避免靜電釋放 避免靜電釋放...
  • Page 9 Preface 回收資訊 回收資訊 回收資訊 回收資訊 建議客戶以符合環保的方式,丟棄使用過的電腦硬體、顯示器、印表機和其他周邊裝置。可能方法包括零部件或整 個產品的再利用,以及回收產品、元件和/或材料。 台灣地區電池回收標誌 台灣地區電池回收標誌 台灣地區電池回收標誌 台灣地區電池回收標誌 甲類 甲類 甲類 甲類 此設備經測試證明符合 BSMI (經濟部標準檢驗局) 之甲類數位裝置的限制規定。這些限制的目的是為了在商業環境中 使用此設備時,能提供合理的保護以防止有害的干擾。此設備會產生、使用並散發射頻能量:如果未遵照製造廠商 的指導手冊來安裝和使用,可能會干擾無線電通訊。請勿在住宅區使用些設備。 警告使用者 警告使用者 警告使用者 警告使用者: : : : 這是甲類的資訊產品,在居住的環境中使用時,可能會造成射頻干擾,在這種情況下,使用者會被要求採取某些適 當對策。...
  • Page 10 Preface Safety Information READ THIS IMPORTANT SAFETY INFORMATION SECTION. RETAIN THIS MANUAL FOR REFERENCE. READ THIS SECTION BEFORE SERVICING. CAUTION! TO REDUCE THE RISK OF ELECTRIC SHOCK, THIS SERVER SHOULD ONLY BE SER- VICED BY QUALIFIED SERVICE PERSONNEL. RTC Battery CAUTION! DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED.
  • Page 11: Typographic Conventions

    Preface CAUTION! DO NOT OVERLOAD THE AC SUPPLY BRANCH CIRCUIT THAT PROVIDES POWER TO THE RACK. THE TOTAL RACK LOAD SHOULD NOT EXCEED 80 PERCENT OF THE BRANCH CIRCUIT RATING. CAUTION! ENSURE THAT PROPER AIRFLOW IS PROVIDED TO COMPONENTS IN THE RACK. DO NOT STEP ON OR STAND ON ANY COMPONENT WHEN SERVICING OTHER COMPO- NENTS IN A RACK.
  • Page 12: Table Of Contents

    Preface T T T T T T T T C C C C C C C C A A A A B B B B L L L L E E E E O O O O F F F F O O O O N N N N T T T T...
  • Page 13 Preface Super IO Configuration USB Configuration PCI Configuration General WHEA Configuration Boot Menu Boot Settings Configuration Boot Device Priority Network Drives Server Menu BMC LAN Configuration Remote Access Configuration Security Menu Exit Menu CHAPTER 4 Using the ESMS About ESMS ESMS Flow Diagram Enter IP address for Authentication Setting the KVM TCP Ports on the Network...
  • Page 14 Preface BIOS Firmware Update Utility BIOS firmware Update Procedure APPENDIX D Mainboard Jumper Settings Jumper APPENDIX C Using Power Consumption Management Power Consumption Management Function Remote Power Control Power Consumption Management Adding New Policies APPENDIX E Specifications...
  • Page 15 Preface Overview WARNING! Before removing the server cover, disconnect all power, unplug the AC power cord, disconnect all peripherals, and all LAN lines. Make sure you have a stable, clean working environment. Dust and dirt can get into system components and cause a malfunction.
  • Page 17: Introduction

    There are two available SKUs which support up to twelve Hard Disk Drives (HDD) and two internal SATA Solid State Drives (SSD). The QSSC-980 Server System rear I/O ports, including two USB ports, 2+1 Gigabit Ethernet LAN ports (with one management port for IPMI), one PS2 mouse port, one PS2 key- board port, one 9-pin serial port, and one 15-pin VGA port.
  • Page 18: Server System Features

    ECC or non-ECC DDR3-1333/1066/800. Please refer to “Installing Memory” on page 20. HDD/SSD The QSSC-980 has 12x 3.5” hot plug HDD cages in the front and 2x 2.5” STAT SSD holder internally. The 3.5” HDD cages can accommodate either 3.5” or 2.5” HDD drives.
  • Page 19: A Tour Of The System

    Use this lever/button to remove the hard drive in HDD bay 1. HDD status LEDs Top LED : Normal: Light Green Fault: Red Bottom LED: Active: Dark Green Logo panel (right) Right panel. QSSC-980 HDD (x 12) Location Left Right Upper HDD12 HDD9 HDD6 HDD3 HDD11...
  • Page 20 System ID LED See table below for behavior. Color Condition Occurrence Blue No identification Blinking Indicates ID Button pressed on chassis Press this button to turn on the QSSC-980 2U. Power button System ID button Press to light ID LED.
  • Page 21: Rear View

    Connect the power cable to the socket. An optional power module can be installed for backup power support. I/O ports Connect I/O devices to these ports. See QSSC-980 2U I/O Ports on page 6. Add-on card Remove these covers before installing any PCI-e card.
  • Page 22 錯誤 尚未定義樣式。 — Introduction QSSC-980 2U I/O Ports The QSSC-980 2U has the following I/O port configuration. Item Port Description PS2 Mouse Port Connect a PS2 mouse to this port. PS2 Keyboard Port Connect a PS2 keyboard to this port.
  • Page 23: System Controls And Leds Description

    錯誤 尚未定義樣式。 — Introduction System Controls and LEDs Description Front System Controls RESET Reset Button Push to restart the system when the system is powered on. Identification Push to clear the ID LED Button Toggles system power. When system is off, push briefly to power on the PSU and Power button the system.
  • Page 24: Installing Hardware

    錯誤 尚未定義樣式。 — Installing Hardware Chapter 2 Safety Measures Computer components and electronic circuit boards can be damaged by discharges of static electricity. Working on computers that are still connected to a power supply can be extremely dangerous. Follow the simple guidelines below to avoid damage to your computer or injury to yourself.
  • Page 25: Qssc-2U Mainboard Components

    錯誤 尚未定義樣式。 — Installing Hardware QSSC-980 2U Mainboard Components The following illustration displays the most important QSSC-980 mainboard components. Figure 1 – Mainboard diagram Item Component PCI slot PCI slot supporting PCI-E I/O ports See QSSC-980 2U I/O Ports on page 6.
  • Page 26: Installing Hard Drives

    錯誤 尚未定義樣式。 — Installing Hardware Installing Hard Drives Follow these instructions to install an HDD: Push the release button in the direction of the arrow The HDD tray-locking handle springs open Open the locking handle and pull to remove the HDD tray...
  • Page 27: Secure A 3.5" Or 2.5" Hard Drive In The 3.5" Tray

    錯誤 尚未定義樣式。 — Installing Hardware Secure a 3.5” or 2.5” Hard Drive in the 3.5” Tray. The 3.5” HDD tray can accommodate either a 3.5” HDD or a 2.5” HDD drive. Both options are depicted in the following guide. Secure the 3.5” hard drive to the tray with four (4) screws as shown. Do not over tighten the screws. Secure the 2.5”...
  • Page 28: Removing The Chassis Cover

    錯誤 尚未定義樣式。 — Installing Hardware Removing the Chassis Cover Refer to the following illustrations for instructions on removing the chassis cover: Remove the securing screw Press the top cover release button Slide the cover back and then remove...
  • Page 29: Removing The Fan Duct

    錯誤 尚未定義樣式。 — Installing Hardware Removing the Fan Duct Refer to the following instructions to remove the fan duct assembly. Locate the fan duct cover and remove the four (4) securing screws Carefully lift up the fan duct cover as shown...
  • Page 30: Installing Cpus

    Installing CPUs WARNING! In a single CPU configuration, the single processor must be installed in the CPU_1 (see QSSC-980 2U Mainboard Components on page 9 for location). socket Refer to the following instructions to install CPUs: Pull the locking lever of the CPU socket out and up as shown.
  • Page 31 — Installing Hardware WARNING! The QSSC-980 2U uses LGA 1366 sockets (Zero Insertion Force sockets), which are designed for trouble free insertion of the CPUs. After placing the CPU into the socket, press the lever down and lock in place. If you notice any resistance when inserting the CPU, ensure that it is aligned correctly.
  • Page 32: Installing Heatsinks

    錯誤 尚未定義樣式。 — Installing Hardware Installing Heatsinks WARNING! If the server board is to be operated with only a single processor, both heatsinks must be installed to insure proper cooling. Refer to the following instructions to install heatsinks: Apply a thermal compound evenly on the top of the CPU. Remove the protective cover from the underside of the heatsink.
  • Page 33: Installing The Fan Duct

    錯誤 尚未定義樣式。 — Installing Hardware Installing the Fan Duct Refer to the following instructions to install the fan duct: Carefully replace the fan duct cover as shown Replace the four (4) securing screws WARNING! Fan ducts are situated over and around the DIMM modules. Ensure that all edges are not lodged inside the memory banks.
  • Page 34: Installing The Redundant Power Supply

    錯誤 尚未定義樣式。 — Installing Hardware Installing the Redundant Power Supply Follow these instructions to install the redundant power supply: Remove the securing screw and the dummy cover from the redundant power supply bay as shown. Insert the redundant power supply as shown.
  • Page 35: Installing An Expansion Card

    錯誤 尚未定義樣式。 — Installing Hardware Installing an Expansion Card CAUTION! VOLTAGES CAN BE PRESENT WITHIN THE SERVER WHENEVER AN AC POWER SOURCE IS CONNECTED. THIS VOLTAGE IS PRESENT EVEN WHEN THE MAIN POWER SWITCH IS IN THE OFF POSITION. ENSURE THAT THE SYSTEM IS POWERED-DOWN AND ALL POWER SOURCES HAVE BEEN DIS- CONNECTED FROM THE SERVER PRIOR TO INSTALLING A PCI CARD.
  • Page 36: Installing Memory

    Installing Memory The mainboard has twelve DDR3-DIMM slots for the installation of up to twelve memory DIMMS @ DDR3- 1066/1333 memory chips. Refer to QSSC-980 2U Mainboard Components on page 9 for the location of the mem- ory modules. Refer to the following instructions to install memory modules: Pull the locking latches of the DIMM slot outwards.
  • Page 37: Supported Dimm Configuration

    Supported DIMM Configuration The following DIMM configurations are supported by the QSSC-980 server. DIMM slots are numbered 1 to 2 and designated by 3 channels, A/B/C for CPU1 and D/E/F for CPU2. Populate DIMM slots starting with slot 1: chan- nel 1(A1 for CPU1 and D1 for CPU2).
  • Page 38 錯誤 尚未定義樣式。 — Installing Hardware Table 2. Registered DIMM Installation Option for 1P Configuration Registered DIMM Installation Option for 1P Configuration DIMM DIMM DIMM DIMM DIMM DIMM Max Speed DIMM Processor Single & Quad Rank Dual Rank Processor 1 1333 1066 Processor 1 1333...
  • Page 39 錯誤 尚未定義樣式。 — Installing Hardware CPU Memory to Speed Configuration The following table provides corresponding information for CPU type to memory speed. CPUs with 6.4 GT/s support memory up to 1333 MHz, while 5.86 GT/s support up to 1066 MHz and 4.8 GHz only support 800 MHz. Memory speed is automatically downgraded to match the supported CPU value.
  • Page 40: Replacing The Fan Assembly

    錯誤 尚未定義樣式。 — Installing Hardware Replacing the Fan Assembly In case of fan failure, you can quickly replace the fan assembly. Follow these instructions to replace the fan assembly: Remove the chassis cover. See Removing the Chassis Cover on page 12. Disconnect the three (3) power cables from the backplane.
  • Page 41: Replacing The Power Supply

    錯誤 尚未定義樣式。 — Installing Hardware Replacing the Power Supply In case of a power supply failure, you can quickly replace the power supply unit. Note: You can also install an optional backup power supply. Contact your dealer for de- tails. See Installing the Redundant Power Supply on page 18. Refer to the following instructions to replace the power supply: Grasp the PSU handle and push in the Lock Release latch...
  • Page 42: Replacing The Riser Card

    錯誤 尚未定義樣式。 — Installing Hardware Replacing the Riser Card Refer to the following illustrations for instructions on replacing the riser card: Remove the top cover. See Removing the Chassis Cover on page 12. Firmly grasp the riser assembly and lift up and away. See the following image. Turn the assembly over and place on a clean static mat.
  • Page 43: Replacing The Backplane

    錯誤 尚未定義樣式。 — Installing Hardware Replacing the Backplane WARNING! Always disconnect power cables before installing or removing any components from the computer, including the backplane. Disconnect the power cable before installing or removing any cables from the backplane. Make sure that the backplane is securely installed to prevent damage to the sys- tem.
  • Page 44: Replacing The Mainboard

    Remove the CPU(s) from the chassis. See Installing CPUs on page 14. Disconnect the power, IPMB, SATA, front panel, and mainboard cable connectors from the mainboard. See QSSC-980 2U Mainboard Components on page 9. Remove the ten (10) screws securing the mainboard in place.
  • Page 45: Replacing The Chassis Cover

    錯誤 尚未定義樣式。 — Installing Hardware Replacing the Chassis Cover Refer to the following instructions to replace the chassis cover: Replace cover and slide in the direction shown (1). Replace the securing screw (2).
  • Page 46: Bios

    錯誤 尚未定義樣式。 — BIOS Chapter 3 Setup Menu The computer employs the latest AMI Core BIOS, which is stored in Flash memory. The Flash memory supports the Plug and Play specification, and contains a BIOS Setup program, the Power On Self Test (POST) routine, and the PCI auto-configuration utility.
  • Page 47: Configuring Special Keys

    錯誤 尚未定義樣式。 — BIOS Value Description Console Redirection function disable Console Redirection to COM1 (3F8H) Configuring Special Keys Console redirection uses ANSI terminal emulation, which is limited to basic ASCII characters. There are no func- tion keys, arrow keys, or control keys in this character set. However, the QSSC-2U BIOS software requires the use of function keys and control keys for ordinary functions.
  • Page 48: The Legend Bar

    錯誤 尚未定義樣式。 — BIOS The Legend Bar The legend bar is at the side of the Setup screen. The keys in the legend bar allow you to navigate through the var- ious setup menus. The following table lists the keys found in the legend bar with their corresponding alternates and functions.
  • Page 49: Main Menu

    [SHIFT-TAB] to AMIBIOS select a field. Version : QSSC-980_3A01 Build Date:06/19/08 Use [+] or [-] to Configure System Time. Product Name : QSSC-980 Board Serial Number : 01234567890124 Processor Genuine Intel(R) CPU @ 0000 2.67GHz Speed :2666MHz Counter :1 ←→...
  • Page 50: Advanced Menu

    錯誤 尚未定義樣式。 — BIOS Advanced Menu This option displays a table of items that define advanced information about your system. Warning! Making incorrect settings to items on these pages may cause the system to malfunction. Unless you have experience adjusting these items, we recommend that you leave these settings at the default values.
  • Page 51: Cpu Configuration

    錯誤 尚未定義樣式。 — BIOS CPU Configuration Scroll to this item and press Enter to view the following screen: BIOS SETUP UTILITY Advanced Configure advanced CPU settings Disabled for Windows XP Intel (R) Xeon(R) CPU 0000 @ 2.67GHz CPUID :106A2 Frequency :2.66GHz FSB Speed :533MHz...
  • Page 52 錯誤 尚未定義樣式。 — BIOS Ratio Actual Value: Information only. Display the ratio at which processors currently run. Hardware Prefetcher:[Enabled] [Disabled] This should be enabled in order to enable or disable the Hardware Prefetcher Disable Feature. It is triggered by regular access patterns and helps predict future access, thereby over- lapping memory latency with computation.
  • Page 53: Memory Configuration

    錯誤 尚未定義樣式。 — BIOS Memory Configuration Scroll to this item and press Enter to view the following screen: BIOS SETUP UTILITY Advanced System Memory Settings Enabled/Disabled Current Memory Frequency 1333Mhz Memory Frequency [Auto]* Memory Mode [Independent]* Throttling – Closed Loop [Enabled]* Throttling –...
  • Page 54: Sata Configuration

    錯誤 尚未定義樣式。 — BIOS SATA Configuration Scroll to this item and press Enter to view the following screen: BIOS SETUP UTILITY Advanced IDE Configuration Options Disabled ATA/IDE Configuration [Compatiable]*1 Compatible Configure SATA#1 as [IDE]* Enhanced ► SATA Port0 [Not Detected] ←→...
  • Page 55: Third Ide Master

    錯誤 尚未定義樣式。 — BIOS Third IDE Master Configure SATA#1 as IDE and the following screen appears: BIOS SETUP UTILITY Advanced Third IDE Master Select the type of device connected to the system. Device :Hard Disk Vendor :ST320410A Size :20.0GB LBA Mode :Supported Block Mode:16Sectors ←→...
  • Page 56 錯誤 尚未定義樣式。 — BIOS PIO Mode: select the device PIO (Programmed Input/Output) mode, which determines the data transfer mode used by IDE drives. PIO mode uses the CPU's registers for data transfer. • Auto: automatically detects optimal or default PIO mode •...
  • Page 57: Super Io Configuration

    錯誤 尚未定義樣式。 — BIOS Super IO Configuration Scroll to this item and press Enter to view the following screen: BIOS SETUP UTILITY Advanced Configure Win627DHG Super IO Chipset Allows BIOS to Enable or Disable Floppy Serial Port1 Address [3F8/IRQ4]* Controller. Serial Port2 Address [2F8/IRQ3]* ←→...
  • Page 58: Usb Configuration

    錯誤 尚未定義樣式。 — BIOS USB Configuration Scroll to this item and press Enter to view the following screen: BIOS SETUP UTILITY Advanced USB Configuration Enables support for Legacy USB. AUTO Option disables Legacy support if USB Devices Enabled : no USB devices are connected.
  • Page 59: Pci Configuration

    錯誤 尚未定義樣式。 — BIOS PCI Configuration Scroll to this item and press Enter to view the following screen: BIOS SETUP UTILITY Advanced PCI Configuration Options Disabled NIC1– – – – KAWELA [Enabled with PXE]* Enabled NIC2– – – – KAWELA [Enabled with PXE]* NIC1 MAC Address [xx-xx-xx-xx-xx-xx]...
  • Page 60: General Whea Configuration

    錯誤 尚未定義樣式。 — BIOS General WHEA Configuration Scroll to this item and press Enter to view the following screen: BIOS SETUP UTILITY Advanced General WHEA Configuration Enable disable Windows Hardware WHEA Support [Enabled]* Error Architecture. ←→ Select Screen ↑↓ Select Item Change Option General Help Save and Exit...
  • Page 61: Boot Menu

    錯誤 尚未定義樣式。 — BIOS Boot Menu This page enables you to set POST boot parameters. Scroll to this item and press Enter to view the following screen: BIOS SETUP UTILITY Main Advanced Boot Server Security Exit Boot Settings Configure Settings during System Boots.
  • Page 62: Boot Device Priority

    錯誤 尚未定義樣式。 — BIOS Bootup Num-Lock: sets the state of the keyboard keypad on boot. When set to On, the keypad functions as a keypad. When set to Off, the keypad functions as auxiliary cursor movement keys. Wait For ‘F1’ If Error: enable this item to have the system prompt you to press F1 if an error occurs. This enables you to view the error.
  • Page 63: Server Menu

    錯誤 尚未定義樣式。 — BIOS Server Menu This page enables you to configure Server parameters. Scroll to this item and press Enter to view the following screen: BIOS SETUP UTILITY Main Advanced Boot Server Security Exit IPMI Information Configure Remote Access. Status Of BMC Working IPMI Specification Version...
  • Page 64: Bmc Lan Configuration

    錯誤 尚未定義樣式。 — BIOS BMC LAN Configuration Scroll to this item and press Enter to view the following screen: BIOS SETUP UTILITY Server LAN Configuration Enter for IP Address Configuration Channel Number [01]* Channel Number Status: Channel number is OK DHCP Enabled [Disabled]* ←→...
  • Page 65: Remote Access Configuration

    錯誤 尚未定義樣式。 — BIOS Remote Access Configuration Scroll to this item and press Enter to view the following screen: BIOS SETUP UTILITY Server Configure Remote Access Type and parameters Select Remote Access type. Remote Access [Enabled]* Serial port number [COM1] Base Address, IRQ [3F8h,4] Serial Port Mode...
  • Page 66: Security Menu

    錯誤 尚未定義樣式。 — BIOS Security Menu This page enables you to set the security parameters. Scroll to this item and press Enter to view the following screen: BIOS SETUP UTILITY Main Advanced Boot Server Security Exit Security Settings Install or Change the password.
  • Page 67: Exit Menu

    錯誤 尚未定義樣式。 — BIOS Exit Menu Scroll to this item and press Enter to view the following screen: BIOS SETUP UTILITY Main Advanced Boot Server Security Exit Exit Options Exit system setup After saving the Save Changes and Exit changes. Discard Changes and Exit Discard Changes F10 key can be used...
  • Page 68: Using The Esms

    錯誤 尚未定義樣式。 — Using the ESMS Chapter 4 About ESMS The Embedded Server Management System (ESMS) is a multi-function management application that pro- vides administrators an efficient utility for remotely managing single or multiple clients. ESMS provides two console modes–Web Console and Advance Console. The web console mode provides simple management function to do basic management while the Advance console mode, Java Remote Su- pervisor Management (Java RSM), supports more advanced management functions.
  • Page 69: Enter Ip Address For Authentication

    錯誤 尚未定義樣式。 — Using the ESMS Enter IP address for Authentication System default IP address sources from Dynamic Host Configuration Protocol (DHCP) first. If DHCP server is not detected, the BMC IP will be assigned to https://192.168.1.2/ (or URL) instead of DHCP. When connecting to the ESMS using a web browser, SSL is automatically activated after the required mode is se- lected and the user login fields are displayed.
  • Page 70: System Information

    錯誤 尚未定義樣式。 — Using the ESMS Figure 4 – Web Console Authentication The default username is root. The default password is changeme. After passing authentication, the following web page appears. Figure 5 – Versions Screen Web Console provides the basic management utility for the user to view system information and events, perform simple system tasks and modify system configuration of managed servers remotely.
  • Page 71 錯誤 尚未定義樣式。 — Using the ESMS Versions Click the Versions tab to view Version Information including: the Device ID, Device Version, Firmware Version, and IPMI Version numbers. Figure 7 – Version Information Session Time-Out Click the Session Time-Out tab. Figure 8 – Session Time Out Settings Click Enable and select a timeout value from the drop-down list.
  • Page 72 錯誤 尚未定義樣式。 — Using the ESMS Figure 9 – Components Screen...
  • Page 73: System Monitoring

    錯誤 尚未定義樣式。 — Using the ESMS System Monitoring The System Monitoring tab enables the administrator to view data about the system, including LED, system, fan, temperature and voltage status, and event logs. Click the System Monitoring tab to view the following web page. Figure 10 –...
  • Page 74 錯誤 尚未定義樣式。 — Using the ESMS Figure 11 – System Monitoring Summary • Fan Status: indicates the health status of the CPU fans and SYS fans for CPUs and SYS that are installed. • Temperature Status: indicates the status for such items as the baseboard and processor temperature, and thermal control.
  • Page 75 錯誤 尚未定義樣式。 — Using the ESMS Click the Fan tab to view CPU and SYS fan information. Figure 12 – System Monitoring Fan Note: This page will automatically update every 10 seconds. Temperature Click the Temperature tab to view system component temperature information. Figure 13 –...
  • Page 76: Event Logs

    錯誤 尚未定義樣式。 — Using the ESMS Voltage Click the Voltage tab to view system component voltage information. Figure 14 – System Monitoring Voltage Note: This page will automatically update every 10 seconds. Event Logs Click the Event Logs tab to view reports about system events. Figure 15 –...
  • Page 77 錯誤 尚未定義樣式。 — Using the ESMS Fault LED Click the Fault LED tab to view the following screen. Figure 16 – System Monitoring Fault LED Click on the desired setting. • Turn Fault LED Off: sets the fault LED on the server to off.
  • Page 78: Configuration

    錯誤 尚未定義樣式。 — Using the ESMS Configuration The Configuration tab enables you to set Network, Platform Event Filter, E-mail Notification, Clock and Gener- ate New and Upload SSL Certificate. Figure 17 – Configuration Network Click the Network tab to set network parameters. Figure 18 –...
  • Page 79 錯誤 尚未定義樣式。 — Using the ESMS • Host Name: enter the Host Name of the LAN, if required. • DNS Server: enter the DNS Server address of the LAN, if required. Click Submit to save the changes. Event Filter The Event Filter tab allows you to modify the Trap Receiver Destination Address. Click the Event Filter tab to display the following web page.
  • Page 80 錯誤 尚未定義樣式。 — Using the ESMS Figure 20 – Configuration E-mail Notification Enter server, sender, and receiver details and click Submit. Clock The Clock page displays the server Date and Time. Click the Clock tab to view the following web page. Figure 21 –...
  • Page 81 錯誤 尚未定義樣式。 — Using the ESMS Figure 22 – Configuration SSL Certification Generating a CSR Before you can create the SSL Certificate, you must first generate a CSR (Certificate Signing Request) on your server. A CSR is a body of text that contains encoded information specific to your company and domain name. You can generate a CSR or upload a manually created CSR.
  • Page 82: User Management

    錯誤 尚未定義樣式。 — Using the ESMS Click Submit. A CSR key is generated and uploaded automatically. Uploading a Manually Created CSR Click the Browse button next to Certificate Upload, and browse to the location of the saved key, for ex- ample Savekey.pem.
  • Page 83 錯誤 尚未定義樣式。 — Using the ESMS Adding an user account Click Add button. The following screen appears. Figure 26 – User Management Adding User Accounts Type the Username in the text box. Type the Password in the text box and type it again for confirmation. Type the E-mail address in the text box.
  • Page 84 錯誤 尚未定義樣式。 — Using the ESMS Figure 27 – User Management Editing User Information • Edit Change E-mail: Click to change the user’s mail. Change Phone: Click to change the user’s phone. Change Privilege: Click to change the user’s privileges. Disable: Click to prevent the user access to the server.
  • Page 85: Ads Configuration

    錯誤 尚未定義樣式。 — Using the ESMS ADS Configuration The ADS Configuration web page enables the administrator to configure an Active Directory Server (ADS). Figure 29 – User Management ADS Configuration ADS Configuration requires a Domain Name Server (DNS), an Active Directory Server (ADS), a Certificate Au- thority Server (CAS), and an AD certificate.
  • Page 86: Remote Control

    錯誤 尚未定義樣式。 — Using the ESMS Remote Control Click the Remote Control tab to view the following web page. Remote Power Control This feature enables the administrator to power on or power down the system remotely. Note: The IPMI connector must be connected to enable this function. Click the Remote Power Control tab to view the following web page.
  • Page 87: Maintenance

    錯誤 尚未定義樣式。 — Using the ESMS Maintenance The Maintenance web page enables you to update the firmware, BIOS and reset the firmware. Firmware Update Use the Firmware Update feature to upgrade to the latest firmware version. See Using Firmware Management on page 100 for more information on updating firmware.
  • Page 88: Using Esms Advance Console Mode

    錯誤 尚未定義樣式。 — Using the ESMS Figure 33 – Maintenance Reset Firmware Click Reset Firmware to restore the default values. Using ESMS Advance Console Mode This mode provides access to all ESMS functions and is designed for administrator systems tasks and moni- toring for multiple servers.
  • Page 89 錯誤 尚未定義樣式。 — Using the ESMS Figure 35 – Java RSM Panel Description Item Description Displays tree structure that will display information for all discov- BMC Host List Panel (Red) ered BMC hosts. Function Selection Panel Lists all supported functions. Users can select functions by using (Yellow) the TAB buttons.
  • Page 90 錯誤 尚未定義樣式。 — Using the ESMS Figure 36 – Auto Server Discovery Diagram Authentication and Privilege Before using Java RSM, the user must finish the authentication process to Java RSM functions acquire privileges. Enter a valid user ID and password to access the selected host. The following web page displays after a successful authentication to the selected BMC Host.
  • Page 91 錯誤 尚未定義樣式。 — Using the ESMS Figure 38 – Authentication Failure Result BMC Host List Functions The Java RSM supports common Host List functions to quickly configure remote BMC hosts. These functions are accessed through a pop-up menu by right-clicking the mouse button on the required host. Figure 39 –...
  • Page 92 錯誤 尚未定義樣式。 — Using the ESMS Figure 40 – Network Configuration Settings Make any desired changes to the information displayed and click Submit to save the new configuration. Note: Deselect Assign IP Address By DHCP Server to make changes to IP, Netmask, and Gateway information.
  • Page 93: Using Server Summary

    錯誤 尚未定義樣式。 — Using the ESMS Using Server Summary System summary briefs information of remote server host. Item descriptions are summarized in the follow- ing table. Figure 41 – Using Server Summary Item Description Host Address Indicates the BMC host IP Address MAC Address Indicates the BMC host Ethernet card MAC address Host Name...
  • Page 94: Using Server Management

    錯誤 尚未定義樣式。 — Using the ESMS Using Server Management The Server Management tab provides access to the Account Management, Platform Event Filter and Notification Configuration sub-functions. Account Management The Account Management sub-function is designed to add, modify, and delete user accounts and their associated application privileges.
  • Page 95 錯誤 尚未定義樣式。 — Using the ESMS Figure 43 – Managing User Accounts Click Submit to add the new user. • Update—select a user and click Update to display the update screen. Figure 44 – Managing User Accounts Updates Make any desired modifications and click Submit to save the changes. •...
  • Page 96 錯誤 尚未定義樣式。 — Using the ESMS Managing Function Privileges Every function of the Java RSM requires specific privilege to execute and the Privilege Management panel deter- mines what privileges are associated with a particular user group. All users belong to one of four groups— Administrator, Operator, User, and Callback—on a sliding scale of function privilege, Administrator being the most powerful group.
  • Page 97 錯誤 尚未定義樣式。 — Using the ESMS Figure 49 – Platform Event Filter Item Description PEF configuration target host filter area. (Yel- Utility for filter the wanted information of target host. low) Global Configuration of Platform Event Filter Show the current global configuration of target host and pro- vide the adjust function that user can configure the (Red Block) configuration by selecting the radio button, checking the check...
  • Page 98: Notification Configuration

    錯誤 尚未定義樣式。 — Using the ESMS Note: When multi-users are using PEF, click the Reload button to obtain the latest data. Maximum 6 configurations can be recorded. Notification Configuration User can configure the mail notification to allow remotely BMC host to send system event alert through mail. Figure 50 –...
  • Page 99: Using Server Monitor

    錯誤 尚未定義樣式。 — Using the ESMS Note: Accounts set in Account Management will be automatically in the Default Mail List. Maximum 7 accounts will be listed in Default Mail List. Using Server Monitor The Server Monitor displays information about specific remote system status. All discovered hosts relay informa- tion to the Server Monitor, which is then sorted in to an Event Log, and item specific sub-functions including system temperature, system voltage, system fan speed, and system components.
  • Page 100: System Temperature

    錯誤 尚未定義樣式。 — Using the ESMS System Temperature All system environmental conditions sensed by BMC are recorded on the Temperature page directly from the sen- sor build integrated in the remote server. Figure 52 – Server Monitor System Temperature Item Description Filter Panel Select the host temperature conditions to display.
  • Page 101 錯誤 尚未定義樣式。 — Using the ESMS System Voltage All system voltage conditions sensed by BMC are recorded on the Voltage page directly from the sensor build in- tegrated in the remote server. Figure 53 – Server Monitor Voltage Item Description Filter Panel Select the host voltage conditions to display.
  • Page 102 錯誤 尚未定義樣式。 — Using the ESMS System Fan Speed All system fan speed conditions sensed by BMC are recorded on the Fan Speed page directly from the sensor build integrated in the remote server. Figure 54 – Server Monitor Fan Speed Item Description Filter Panel...
  • Page 103: System Components

    錯誤 尚未定義樣式。 — Using the ESMS System Components All CPU and memory information of remote systems is recorded on the Component page directly from the com- ponent build integrated in the remote server. Figure 55 – Server Monitor Components Item Description Filter Panel Select the host component information to display.
  • Page 104: Using Remote Kvm Console

    錯誤 尚未定義樣式。 — Using the ESMS Using Remote KVM Console Remote Keyboard, Video, and Mouse (KVM) over IP redirects server video screen, keyboard, and mouse data to or from a remote console PC over a network enabling administrators to operate and monitor servers remotely. Figure 56 –...
  • Page 105: Mouse Synchronization At Console Side

    錯誤 尚未定義樣式。 — Using the ESMS Keyboard and Mouse redirection Once the Remote KVM function is launched, Java RSM emulates USB 2.0 keyboard and mouse devices. As a re- sult, the managed server’s BIOS or OS will detect the USB keyboard and mouse attached, and loads their drivers to service them.
  • Page 106 錯誤 尚未定義樣式。 — Using the ESMS acceleration function to exaggerate the mouse movement vectors and increase the cursor move speed. When using Relative mode, ensure that mouse acceleration is turned off. Absolute mode—only supported by Windows and Mac OSX operation systems. The mouse cursor axis position references the absolute axis position of physical mouse device.
  • Page 107 錯誤 尚未定義樣式。 — Using the ESMS Hardware Cursor Mode Java RSM provides the means to separate mouse data from video data and sends the cursor position directly to the console end after positional updates or icon changes. In this mode, video image transmits become fewer and mouse movement becomes smoother.
  • Page 108 錯誤 尚未定義樣式。 — Using the ESMS Hot-Key Simulation Since Windows or other application programs have priority in using hot-keys before the remote server, (for exam- ple Ctrl-Alt-Del), the Java RSM ignores these keys and does not send them. However, you can assign hotkeys in the Java RSM application and these hotkeys are available on the menu-bar where the user can select hot keys to send to ESMS and the managed server directly, instead of pressing keys.
  • Page 109 錯誤 尚未定義樣式。 — Using the ESMS Virtual Keyboard Utility The Virtual Keyboard utility improves the limited support of different language keyboards in the java environ- ment. Every key on virtual keyboard dialog is mapped to USB HID Code. Clicking a virtual key sends a simulated USB HID message in place of a non-supported language key.
  • Page 110 錯誤 尚未定義樣式。 — Using the ESMS Figure 69 – Remote KVM Enable Scaling Display The screen size is automatically adjusted to fit the local screen size. Figure 70 – Remote KVM Adjust to Local Screen Size Video Quality Adjustment In order to meet different user’s network bandwidth and video quality requirements, the video quality ad- justment function allows for video quality scaling.
  • Page 111 錯誤 尚未定義樣式。 — Using the ESMS Video Contrast Adjustment The Video Contrast Adjustment function allows for adjustment of contrast parameters for the incoming video. To adjust the contrast, click Console Option and select Gamma Tuner. Use the gamma value slide to select the desired gamma value.
  • Page 112: Using Virtual Storage

    錯誤 尚未定義樣式。 — Using the ESMS Using Virtual Storage The Virtual storage function provides storage redirection to a host platform from a remote site over a network as shown in the illustration below. The Java RSM creates a socket connection with the VStorage service and sends a socket packet of the physical storage device or ISO image file information (device type, is read only and encryp- tion type) at client side to VStorage.
  • Page 113 錯誤 尚未定義樣式。 — Using the ESMS Mounting Virtual Devices Available physical devices are auto-detected by the Java RSM and added to a drop down list for selection and mounting. The following table describes the currently supported physical devices and the associated read/write status.
  • Page 114 錯誤 尚未定義樣式。 — Using the ESMS Figure 77 – Demounting Virtual Devices The Java RSM handles the demount automatically, and the virtual device is removed from the status panel. Virtual Storage Status All mounted virtual storage devices are listed in the Remote Virtual Storage Device Status panel in the Virtual Storage tab.
  • Page 115 錯誤 尚未定義樣式。 — Using the ESMS Changing Device Image Files The Java RSM supports changing device image files without the need to demount and remount the associated de- vice. To change the image file of a virtual device, perform the following steps: Select the device in the Remote Virtual Storage Device Status panel as shown and click Change.
  • Page 116 錯誤 尚未定義樣式。 — Using the ESMS Using Firmware Management The Java RSM Firmware Management function provides a simple interface for upgrading remote BMC firmware individually or simultaneously. Firmware Management also provides a reset function, returning the selected host to the default firmware. Figure 80 –...
  • Page 117: Using Power Control Management

    錯誤 尚未定義樣式。 — Using the ESMS Using Power Control Management The Java RSM Power Control Management function controls the power state of remote servers. The utility en- ables the administrator to power on/off, or reset remote server power locally or remotely. The addition of a scheduling function enables the administrator to manage server power status at specified dates and times.
  • Page 118 錯誤 尚未定義樣式。 — Using the ESMS Scheduling Power State Changes To schedule individual or multiple server power state changes, perform the following steps: Select Scheduled and enter the date and time for the power state change to occur. Select the desired power status from the drop down menu. Select the servers to receive the state change signal in the Power Status panel.
  • Page 119: Support

    錯誤 尚未定義樣式。 — Support Appendix A Installing the Rack Brackets When the server is to be installed into a rack, it is necessary to install two rack mount brackets onto the server chassis prior to installing the server into the rack. Follow the procedures below to install the rack mount brackets onto the server.
  • Page 120 錯誤 尚未定義樣式。 — Support Remove any plastic cover from the rackmount. CAUTION! THE SERVER SYSTEM IS HEAVY. TO AVOID PERSONAL INJURY, TWO INDIVIDUALS ARE REQUIRED TO LIFT AND PLACE THE SERVER INTO POSITION. Slide the server onto the rails, and push back until it sits flush against the vertical supports on the cabinet. The server must rest completely on the rails.
  • Page 121: Troubleshooting Sequence

    Power Connector Not Plugged In If the power supply cable is not plugged into the Mainboard CPU power connector (see QSSC-980 2U Mainboard Components on page 9 for the location), the system cannot boot up, even though chassis front panel LEDs and the fan may be operational.
  • Page 122 錯誤 尚未定義樣式。 — Support Defective memory modules may cause boot errors. One, two or three beeps at boot indicate defective memory. To isolate a specific memory module as defective, boot the system with just one memory module installed at a time. Monitor Issues Monitor configurations can cause boot failure.
  • Page 123: Installation Problems

    (such as a printer, keyboard, mouse, or other external device). Ensure that all external cables are se- curely attached to the external connectors on your system. See QSSC-980 2U I/O Ports on page 6 for the back panel connectors on your system.
  • Page 124: Status Led Descriptions

    錯誤 尚未定義樣式。 — Support Status LED Descriptions Front Panel Location Name Icon Color Display Status Description Status LED Amber Amber BLINK Non-critical Failure: non- critical fan, voltage, tem- perature state, CPU thermal trip NIC2 LED Green Link Green BLINK Link, Access NIC1 LED Green Link...
  • Page 125: Irq Assignment Conflicts

    錯誤 尚未定義樣式。 —Support IRQ Assignment Conflicts Most PCI devices can share an IRQ with another device, but they cannot use an IRQ simultaneously. To avoid this type of conflict, see the documentation for each PCI device for specific IRQ requirements. IRQ Line Assignment IRQ Line...
  • Page 126 錯誤 尚未定義樣式。 — Support command byte is being done after Auto detection of KB/MS using AMI KB-5. Initializes the 8042 compatible Key Board Controller. Detects the presence of PS/2 mouse. Detects the presence of Keyboard in KBC port. Testing and initialization of different Input Devices. Also, update the Kernel Variables. Traps the INT09h vector, so that the POST INT09h handler gets control for IRQ1.
  • Page 127 錯誤 尚未定義樣式。 —Support Execute BIOS setup if needed / requested. Late POST initialization of chipset registers. Build the ACPI tables. Program the peripheral parameters. Enable/Disable NMI as selected Late POST initialization of system management interrupt. Check boot password if installed. Clean-up work needed before booting to OS.
  • Page 128: Beep Codes

    錯誤 尚未定義樣式。 — Support Beep Codes The following table describes the beep codes that are used in boot block: Number of Description Beeps 1 beep if no media 2 beeps for boot-block bios file absent 3 beeps for insert next diskette in A: 4 beeps for flash program successful 5 beeps for read file error 7 beeps for no flash present...
  • Page 129: Updating The Bmc Firmware

    錯誤 尚未定義樣式。 — Updating the BMC Firmware Appendix B BMC Firmware Update Utility The BMC (Baseboard Management Controller) firmware update utility is a DOS-based program used to update the BMC firmware code. This utility should only be run if new firmware code is necessary. BMC Firmware Update Procedure There are two means to update BMC Firmware.
  • Page 130: Updating Bios

    錯誤 尚未定義樣式。 — Updating BIOS Appendix C BIOS Firmware Update Utility The BIOS (Basic Input and Output System) Firmware update utility is a Web/DOS-based program used to update the BIOS firmware version. This utility should only be run if new firmware version is necessary. BIOS firmware Update Procedure There are two means to update BIOS firmware.
  • Page 131: Mainboard Jumper Settings

    錯誤 尚未定義樣式。 — Mainboard Jumper Settings Appendix D The following illustration shows the location of the jumpers on the mainboard: Jumper Location Default Setting Function Password Setting 1-2 : Protect (Default) 2-3 : Clear CMOS Setting 1-2 : Hold(Default) 2-3 : Clear BMC Disable 1-2 : Disable BMC Open...
  • Page 132: Using Power Consumption Management

    Power Supply Management Interface (PSMI) or Power Management Bus (PMBus). Remote Power Control Quanta: Please provide screen shots for this section. Power Consumption Management The following section describes the Power Consumption Management (PCM) menu, configuring the DPNM func- tion menu and the setting of PCM policies.
  • Page 133 錯誤 尚未定義樣式。 — Using Power Consumption Management Item Description Enable or Disable DPNM policy control mechanism. If the state of the selected policy is disabled, all defined power budget management policies are not implemented. To record the current power consumption value of selected target host to the graph.
  • Page 134 錯誤 尚未定義樣式。 — Using Power Consumption Management Click Enable DPNM from the menu. Note: When enabling DPNM, ensure the Power State on the selected server system is checked (power on). Disabling DPNM From the Host List frame, select a system with DPNM enabled, and tick the correlating radio-button. Click Disable DPNM to disable the server system.
  • Page 135: Adding New Policies

    錯誤 尚未定義樣式。 — Using Power Consumption Management Adding New Policies You can set new, edit and delete existing, enable and disable existing and reload policies through the PCM Poli- cies pane. See the following image. From the Group Pane, click New Policy. Click Configuration to complete the process.
  • Page 136 錯誤 尚未定義樣式。 — Using Power Consumption Management Item Description Assign a temperature upper bound value to trigger the power limiting function. Check to send alert when power limit is reached. Check to enable defined policy. Select the default or user defined Correction Time Configura- tion values.
  • Page 137 錯誤 尚未定義樣式。 — Using Power Consumption Management Click the Delete Policy button to delete the selected policy. Enabling Policies From the Policy List frame, select a disabled policy to enable as shown in the following image. Click the Enable Policy button to enable the inactive policy. Disabling Policies From the Policy List frame, select a policy to disable as shown in the following image.
  • Page 138: Specifications

    Appendix E Component Feature Description Form Factor SSI EEB 2.0, 12’’ x 13’’, 2U thermally optimized Processors Two FC-LGA 1366 socket support Intel QuickPath, Interconnect 6.4 GT/s for CPU Bus, Nehalem-EP or Westmere-EP 2S • Chipset Tylersburg-36D Intel Quick Path Interconnect up to 6.4GT/s •...

Table of Contents