TABLE 8-24
#
fmdump
TIME UUID SUNW-MSG-ID
Jul 02 10:04:15.4911 0ee65618-2218-4997-c0dc-b5c410ed8ec2 SUN4-8000-0Y
fmdump -V
The -V option provides more details.
TABLE 8-25
# fmdump -V -u
0ee65618-2218-4997-c0dc-b5c410ed8ec2
TIME
Jul 02 10:04:15.4911 0ee65618-2218-4997-c0dc-b5c410ed8ec2 SUN4-8000-0Y
100% fault.io.fire.asic
FRU: hc://product-id=SUNW,A70/motherboard=0
rsrc: hc:///motherboard=0/hostbridge=0/pciexrc=0
Three lines of new output are delivered with the -V option.
The first line is a summary of information displayed previously in the console
message but includes the timestamp, the UUID, and the Message-ID.
The second line is a declaration of the certainty of the diagnosis. In this case the
failure is in the ASIC described. If the diagnosis could involve multiple
components, two lines would be displayed here with 50 percent in each, for
example.
The FRU line declares the part that needs to be replaced to return the system to a
fully operational state.
The rsrc line describes what component was taken out of service as a result of
this fault.
fmdump -e
To get information of the errors that caused this failure, use the -e option.
TABLE 8-26
# fmdump -e
TIME
Nov 02 10:04:14.3008 ereport.io.fire.jbc.mb_per
UUID
CLASS
SUNW-MSG-ID
Chapter 8 Diagnostics
189