Performing a Nonmirrored Disk Hot-
Plug Operation
Verify which disk drive corresponds with which logical device name and physical
device name. See:
"About Physical Disk Slot Numbers, Physical Device Names, and Logical Device
Names" on page 123
Ensure that no applications or processes are accessing the disk drive.
You need to refer to the following document to perform this procedure:
Sun Fire V445 Server Service Manual
To View the Status of the SCSI Devices
1. Type:
TABLE 6-31
# cfgadm -al
For example:
TABLE 6-32
# cfgadm -al
Ap_Id
c0
c0::dsk/c0t0d0
c1
c1::dsk/c1t0d0
c1::dsk/c1t1d0
c1::dsk/c1t2d0
c1::dsk/c1t3d0
c2
c2::dsk/c2t2d0
usb0/1
usb0/2
usb1/1
usb1/2
#
136
Sun Fire V445 Server Administration Guide • September 2007
Type
Receptacle
scsi-bus
connected
CD-ROM
connected
scsi-bus
connected
disk
connected
disk
connected
disk
connected
disk
connected
scsi-bus
connected
disk
connected
unknown
empty
unknown
empty
unknown
empty
unknown
empty
Occupant
Condition
configured
unknown
configured
unknown
configured
unknown
configured
unknown
configured
unknown
configured
unknown
configured
unknown
configured
unknown
configured
unknown
unconfigured ok
unconfigured ok
unconfigured ok
unconfigured ok
Need help?
Do you have a question about the Sun Fire V445 Server and is the answer not in the manual?
Questions and answers