4. Streaming data
The number of sessions will be displayed. For example, if you are connected with the
128 kbps service to two applications, the number of sessions will be "2."
For example;
- Streaming 64 k Browser ---> Connected
- Streaming 64 k Windows Media player ---> Connected
- Streaming 64 k Quick Time ---> Connected
10.2.6 Temperature information
1. HPA
The temperature detected for the Antenna unit HPA Module is displayed.
When the temperature of the HPA Module gets as high as +95 degrees or more, the
following Warning message will be displayed; "(ADE) HAP temperature fault." When
the temperature of the HPA Module gets as high as +95°C or more, output will be
stopped automatically, and therefore communication will not be established.
2. IF
The temperature of the Communication unit IF board is detected. The detected data is
used for displaying the temperature only, and is not used for any control.
When the temperature of the IF board gets as high as +75°C or more, the following
Warning message will be displayed; "(Modem) IF: Temperature high."
When the temperature of the IF board gets as low as less than -25°C, the following
Warning message will be displayed; "(Modem) IF: Temperature low."
When abnormal temperature shown above is detected, the system may not be able to
operate in a normal manner since the detected temperature is not within the range of the
temperature specification of the IF board.
3. Modem
The temperature of the Communication unit MODEM board is being detected. The
detected data is used for displaying the temperature only, and is not used for any
control.
When the temperature of the Modem board gets as high as +80°C or more, the
following Warning message will be displayed; "(Modem) Temperature high."
When the temperature of the MODEM board gets as low as less than -25°C, the
following Warning message will be displayed; "(Modem) Temperature low."
When abnormal temperature shown above is detected, the system may not be able to
operate in a normal manner since the detected temperature is not within the range of the
temperature specification of the Modem.
10-11
10.2 Status monitor
}
No. of session: 3