Electrical Requirements

To reduce the risk of electric shock, fire, explosion,
serious injury or death:
Disconnect electric power to the tumble dryer be-
fore servicing.
Close gas shut-off valve to gas tumble dryer be-
fore servicing.
Close steam valve to steam tumble dryer before
servicing.
Never start the tumble dryer with any guards/
panels removed.
Whenever ground wires are removed during serv-
icing, these ground wires must be reconnected to
ensure that the tumble dryer is properly ground-
ed.
To reduce the risk of fire and electric shock, check
with a qualified service person for proper grounding
procedures. Improper connection of the equipment
grounding conductor may result in a risk of electric
shock.
To reduce the risk of fire and electric shock, if elec-
trical supply is coming from a three phase service,
DO NOT connect a "High Leg" or "Stinger Leg" to a
single phase machine. On a three phase machine, if
there is a "High Leg" or "Stinger Leg" it should be
connected to L3.
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
Electrical Requirements
WARNING
WARNING
WARNING
IMPORTANT: Electrical connections must be made by
a qualified electrician using data on serial plate, instal-
lation manuals and wiring diagram provided with ma-
chine and according to local codes. Install a circuit
breaker as close to the tumble dryer as possible. If
more than one tumble dryer is being installed, a circuit
breaker must be provided for each.
NOTE: Connect machine to an individual branch circuit
not shared with lighting or other equipment.
NOTE: 3 Phase Machines Only - Do not use fuses to
avoid the possibility of "single phasing" and causing
premature failure of the motors.
In case of servicing (or putting the tumble dryer out
of order), disconnect the tumble dryer from the main
supply by switching off the circuit breaker.
W002R1

Wiring Diagram

The wiring diagram is located in the junction or contactor box.
The wiring diagram part number is in the lower portion of the
electrical data on the serial plate.

Wiring for Central Pay

Applicable for the following control suffixes: 3K, 3L, BK, BL,
W068R1
KK, KL, LK, LL, WK and WL.
System Connections
Connection to central pay systems will be made in the rear jun-
tion box of the tumble dryer. For stack models, connection for
both the lower control and upper control will be made in the up-
per junction box.
Locate the harness with Black, Blue, Gray and Brown wires. The
upper and lower harness can be identified by a yellow label on
the harness tubing indicating "UPPER" and a white label on the
harness tubing indicating "LOWER".
W069
The wire colors will be the same regardless of control type.
Splice the after-market central pay system wires to the tumble
dryer control wire harness as follows.
52
Electrical Requirements
WARNING
Part No. 70457901ENR12