Installation
IMPORTANT: The electronic ignition system will at-
tempt to light the gas by sparking for the "trial for
ignition" period. If gas does not ignite within this
period, the ignition control will go into a safety lock-
out and the valve will no longer open until the con-
trol is reset. It may be necessary to retry several
times to bleed air from the gas lines. To reset, open
and close the loading door and restart tumble dryer.
If lockout condition persists, check that the manual
gas shut-off valve is in the ON position and that the
gas service is properly connected. If condition still
persists, remove tumble dryer from service.
8. Load the cylinder with a full load of clean rags and run to re-
move oil or dirt from cylinder.
9. Check the airflow switch operation by opening the lint panel;
be sure to remove shipping tape from airflow switch prior to
operation. Temporarily tape down the lint panel safety switch
located behind the upper left corner of the lint panel. The
heating systems should shut off when the lint panel is opened
a maximum of 1.5 inches [ 38 mm].
The airflow switch operation may be affected by shipping tape
still in place, lack of make-up air, or an obstruction in the exhaust
duct. These should be checked. If there is a problem, contact an
authorized service person.
Do not operate tumble dryer if airflow switch is
faulty. An explosive gas mixture could collect in
tumble dryer if airflow switch does not operate
properly.
Models
Models through
3/10/13
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
WARNING
CE and
18
Australia
All others
1-3
10. Wipe out the cylinder using an all-purpose cleaner or deter-
gent and water solution. Refer to Figure 14 .
IMPORTANT: The use of chlorine bleach for remov-
ing any discoloration should be avoided because
bleach could damage the finish.
W407R1
Prepurge Time
Trial for Ignition
(seconds)
(seconds)
10
10
30
T452I_SVG
Figure 14
Reset Lockout
Condition By:
025, 030, 035, 055:
Press reset button on
rear of machine
T30, T45: Press lighted
reset button in rear
contactor box
Open loading door
Table continues...