ALLIANCE CA050L Installation Operation & Maintenance page 72

Tumble dryers 50 pound (25 kilogram) capacity 75 pound (34 kilogram) capacity
Hide thumbs Also See for CA050L:
Table of Contents

Advertisement

Operating Instructions
NOTE: One touch drying is available for repetitive
loads. If the START button is pressed while the ma-
chine is in Idle Mode, when the display is dark, the
tumble dryer will repeat the last drying cycle. If the
cycle time is adjusted before the cycle is started,
the time displayed when the start button was press-
ed will be used for future cycles.
IMPORTANT: To stop the tumble dryer at any time
during the cycle, OPEN DOOR. If the loading door or
lint panel door is opened during the cycle, the heat-
ing system will shut off and the motor will stop. To
restart the cycle, both doors must be closed and the
START button must be pressed in.
If the load cools to 90°F [32°C] before cool down time expires,
the control will flash "Lr" (load ready) in the heat time display. If
Display
OP
SH
AF - 1
AF - 2
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
TMB2150N_SVG
Figure 36
Definition
Open thermistor error
Shorted thermistor error
Airflow switch closed when cycle started
Airflow switch failed to close after cycle
started
Table 14  continues...
the door is not opened, the tumble dryer completes the selected
cool down time. If the door is opened after reaching "Lr" temper-
ature, the cycle will be terminated.
NOTE: If display shows an error code, refer to Error
Codes section.
6. When the cycle is complete, open door and remove the laun-
dry.
To prevent the risk of fire, remove laundry imme-
diately in case of power failure.
NOTE: This machine includes an anti-wrinkle/ ex-
tended tumble feature. After the drying cycle is
complete, the cylinder will tumble without heat ev-
ery few minutes. The intermittent tumbling will con-
tinue for one hour or until the door is opened. Anti-
wrinkle feature will tumble the load without heat for
30 seconds every 2 minutes for 1 hour OR until the
loading door is opened.
Error Codes
Corrective Action
Check thermistor. Replace if inoperative.
Check wiring diagram between control and thermistor.
Refer to wiring diagram for proper wiring.
Check control. Replace if inoperative.
Check thermistor. Replace if inoperative.
Check wiring between control and thermistor. Refer to
wiring diagram for proper wiring.
Check control. Replace if inoperative.
Check airflow switch. Replace if inoperative.
Check airflow switch. Replace if inoperative.
72
WARNING
Part No. 70457901ENR12
W779

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ca050nCk050nCt050lCt050nCu050lCu050n ... Show all