050 and Classic Line 075 Series Electric Models
Serial Plate Rating
240V/50Hz/1ph (050 Series
only)
200-208V/60Hz/3ph
200V/50Hz/3ph
230V/50Hz/3ph
240V/50Hz/3ph
240V/60Hz/3ph
380V/50 or 60Hz/3ph
400-415V/50Hz/3ph
440V/60Hz/3ph
480V/60Hz/3ph
Eco Line 075 Series Electric Models
Serial Plate Rating
200-208V/60Hz/3ph
240V/60Hz/3ph
380V/50Hz/3ph
380V/60Hz/3ph
400-415V/50Hz/3ph
440V/60Hz/3ph
460-480V/60Hz/3ph
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
Terminal Block
Connections Re-
quired
L1, Neutral and Ground
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
Table 11
Terminal Block Con-
nections Required
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, L2, L3 and ground
Table 12
Serial Plate Amps
Nonre-
Revers-
versing
ing
93
95
89
88
84
85
73
75
79
78
79
78
47
48
43
44
41
41
38
38
Serial Plate Amps
Nonrevers-
Revers-
ing
ing
63
63
56
56
34.3
35.3
32.6
32.6
32.3
33.3
28.4
28.4
26.9
26.9
61
Electrical Requirements
Recommended Circuit
Wire Size
Breaker
AWG
2
Rating
[mm
125A – 1 pole
1 [35]
125A – 3 pole
1 [35]
125A – 3 pole
1 [35]
100A – 3 pole
3 [26.7]
100A – 3 pole
3 [26.7]
100A – 3 pole
3 [26.7]
60A – 3 pole
6 [16]
60A – 3 pole
6 [16]
50A – 3 pole
6 [16]
50A – 3 pole
6 [16]
Recommended Circuit
Wire Size
AWG
Breaker
2
[mm
Rating
80A - 3 pole
4 [25]
70A - 3 pole
4 [25]
45A - 3 pole
8 [10]
45A - 3 pole
8 [10]
40A - 3 pole
8 [10]
40A - 3 pole
8 [10]
35A - 3 pole
8 [10]
Part No. 70457901ENR12
]
]