ALLIANCE CA050L Installation Operation & Maintenance page 36

Tumble dryers 50 pound (25 kilogram) capacity 75 pound (34 kilogram) capacity
Hide thumbs Also See for CA050L:
Table of Contents

Advertisement

Installation
1. Gas Valve
2. Regulator Plate
3. Burner Orifice
4. Burner Tube Openings
5. Burner
6. Pressure Tap
7. Spud Holder
8. Manifold Pipe
9. Anti-Torque Ring
10. Spud Holder Nut
11. Plate
12. Gasket
13. Regulator Cap
How to Adjust Gas Valve Governor/Regulator
1. Check gas burner orifice (manifold) pressure as follows. Re-
fer to Figure 16 .
2. Remove screw plug from pressure tap.
3. Connect a "U"-tube manometer (or similar pressure gauge) to
the burner orifice (manifold) pressure tap.
4. Start tumble dryer and note pressure once flame is burning.
Remove regulator cap and adjust regulator screw until the
burner orifice pressure per applicable table is achieved. Re-
place regulator cap. Refer to Figure 16 .
5. Commission tumble dryer for use.
Burner Orifice
1
1. Size Stamped on Orifice
Figure 17
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
2
1
13
12
10
9
8
11
TMB2015N_SVG
4
3
6
7
Figure 16
36
5
TMB2282N_SVG
Part No. 70457901ENR12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ca050nCk050nCt050lCt050nCu050lCu050n ... Show all

Table of Contents