Cool Down Per Cycle (in minutes)
4
Models Starting Serial No. 0909xxxxx
Cool Down
Cool Down
Switch Num-
Per Cycle (in
ber
minutes)
7
1 (factory default)
OFF
3
ON
Total Cycle Time = Heat Time + Cool Down Time

Topoffs

Any time the control receives a coin drop pulse during a cycle it
will add the programmed dry time to the time currently remaining
in the cycle. The maximum cycle time is 99 minutes, the control
will not add time beyond 99 minutes. The cool down time will
not change.
If the control receives a coin drop pulse during cool down the IN
USE LED will flash briefly to indicate the coin input, the ma-
chine will exit cool down and it will start heating. The cycle time
will be equal to the programmed dry time.

Temperature Selector Switch

For five minutes after the control is powered up, there is a diag-
nostic feature that allows the temperature selector switches to be
tested.
When the temperature selector is changed, the new setting is dis-
played by flashing the IN USE LED as follows:
High/Normal

Error Codes

Display
AF (flashing)
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
Cool Down Switch Number
ON
Cycle Reset
Switch Num-
ber
8
OFF
ON
4 flashes
Table continues...
Definition
Airflow switch opened/closed 5 or more
times in a running cycle.
ON
Medium/PP
Low/Delicate
No Heat
NOTE: To change dipswitch settings refer to Dipswitch
Settings section.

To Program a Short Test Cycle

1. Unplug machine power cord.
2. Write down machine control dip switch settings, then set
them all to the off position. Refer to Figure 30 .
3. Plug machine in and start a cycle.
NOTE: With all control dip switches off, the total cy-
cle time will be 2 minutes long (1 minute of heat and
1 minute of cool down).
4. Once all testing is complete, unplug machine and re-set dip
switches to their original settings.
5. Plug machine in.
Corrective Action
Check airflow switch. Replace if inopera-
tive.
69
Single Drop Timer
3 flashes
2 flashes
1 flash
TMB2216N_SVG
Figure 30
Part No. 70457901ENR12