Dry
Tim
Default
e
Pro-
(Mi
grams
n.)
2 – Sheets
30
3 – Misc-1
30
4 – Misc-2
25
5 – Extra
5
Dry
NOTE: If an altered program is determined to be cor-
rupted, the default program settings will be used.
Features
Drying time: 0-60 minutes
Cooling time: 2-60 minutes
LED display of cycle time, set temperature, and actual tem-
perature
Thermistor controlled temperature
Safety tumble cycle
Buzzer for end of cycle, audible alarm
Reversing/Nonreversing selection
Five user programmable programs
RPM display – when equipped with rotational sensor only
Monitors the lint door switch operation
Monitors the thermistor for operation
The minimum drying time is 0 minutes, and the minimum cool-
ing time is 2 minutes. The maximum drying or cooling time is 60
minutes. The drying temperature may be set from 100ºF [38ºC] to
185º/195ºF [85º/91ºC]. The drying time, cooling time, or temper-
ature may be modified during an operating cycle.
If it is necessary to reset the drying and cooling times for the cur-
rent cycle, press STOP once to stop the tumble dryer. Press
STOP again to cancel the cycle.
If it is necessary to change programs during a current cycle, press
STOP once to stop the tumble dryer and press STOP again to
cancel the current cycle.
Programming
1. Set DIP switch #8 to the ON position.
2. Select the desired program number to change. The LED
should be flashing.
3. Select DRY TIME. Set the time with the Up/Down arrows.
4. Select COOL TIME. Set the time with the Up/Down arrows.
5. Select TEMPERATURE. Set the temperature with the Up/
Down arrows.
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
Cool
Temp.
Time
Set
(Min.)
Point
5
165ºF [74ºC]
5
150ºF [66ºC]
5
135ºF [57ºC]
2
150ºF [66ºC]
6. Select reversing REV (illuminated) or nonreversing REV (not
illuminated). To change basket direction and dwell time, see
Re-
Reversing Operation.
ver
7. Press and hold the Program Select button about 3 seconds un-
s-
til the LED stops flashing. The selected program number is
ing
now programmed. If the Program button is pressed for less
than 3 seconds, the controller will cancel the program and dis-
Yes
play the next program's settings. If not programmed correctly,
the display will flash "E2F" for 4 seconds, and the default set-
No
tings will be used. Follow steps 4 through 7 to reprogram any
program number. When finished, set DIP switch #8 to OFF.
Yes
The programs are now stored.
8. During the Program Mode, if the Up/Down arrows, REV, or
No
Display button is not pressed within 10 seconds, the default
program settings will be used.
9. Temporary Reprogramming of Current Programs (OPL ON-
LY).
10. The Drying Time, Cooling Time, Temperature, and Reversing
Mode of a program currently in use may be modified simply
by adjusting any or all of the program parameters for that pro-
gram, as needed. Once a modification has been made, the cur-
rent program LED will flash indicating that it has been modi-
fied.
11. Use the Up/Down arrows to adjust program time.
12. Use the Display Select button to choose between Drying
Time, Cooling Time, and Temperature. Then use the Up/
Down arrows to adjust the times and temperature.
13. Toggle between reversing REV (illuminated) or nonreversing
REV (not illuminated). (Only for tumble dryers with the re-
versing option.)
14. To cancel this temporary programming mode push the STOP
button once to stop the current cycle and once more to cancel
the modified program settings. The program will revert back
to its original settings.
Reversing Operation
1. When the LOCAL reversing operation is selected, the revers-
ing times are stored in the EEPROM which is located on the
controller board. If the values stored are determined to be in-
valid, the clockwise and counterclockwise times will default
to 60 seconds, and the dwell time will default to 4 seconds.
2. The reversing time program has the following sequence: (1)
clockwise time, (2) dwell time and (3) counterclockwise time.
3. To program new reversing times DIP switches #3 and #8
must be on.
4. Press and hold the reverse button (REV) for 3 seconds to dis-
play the clockwise time.
5. Use the Up/Down arrows to set the clockwise time within the
range of 30-120 seconds.
6. Press REV to display the dwell time.
7. Use the Up/Down arrows to change the dwell time within the
range of 3-10 seconds.
8. Press the REV button to display the counterclockwise time.