19
. SWITCHES/HORN/FUEL UNIT/THERMOSTATIC SWITCH
/TEMPERATURE GAUGE/INSTRUMENTS/LIGHTS
THERMOSTATIC SWITCH
INSPECTION
Remove the front covers. (  2-5)
Start and run the engine to make the water
temperature reaches 90
check if the cooling fan motor operates.
Lower the water temperature to
85
87
and check if the fan motor
stops.
If the fan motor does not start, disconnect
the wires from the thermostatic switch and
then connect a jumper wire between the
wire harness and thermosensor wires (black
and green wires).
Turn the ignition switch ON. The
thermostatic switch is faulty if the cooling
fan motor runs properly.
If it does not start, check for voltage
between the fan motor coupler wire
terminals (black
If there is no voltage, check for the
following:
• Blown or faulty fuse
• Loose terminals or connectors
• Shorted wire in the wire harness

TEMPERATURE GAUGE

Disconnect the wire from the thermosensor
and ground it to the engine.
Turn the ignition switch ON.
The temperature gauge needle should move
all the way to "H".
Do not leave the thermosensor wire
grounded for longer than 5 seconds or
the temperature gauge will be damaged.
and
±2
green).
Thermostatic Switch
Wire
Thermosensor
Thermosensor Wire