Table 4-3
Troubleshooting and Diagnostics
Micro-Move Error Codes
Micro-Move Error Codes
Micro-Move Error Codes
Micro-Move
Description
Error Code
(hex)
01
Vertical over voltage exceeded limit set by firmware
02
Vertical over force exceeded limit set by firmware
03
Vertical servo error
04
Vertical time-out
05
Vertical open path
06
Vertical closed path
0A
Plunge over voltage exceeded limit set by firmware
0B
Plunge over force exceeded limit set by firmware
0C
Plunge servo error
0D
Plunge servo error
0E
Plunge open path
0F
Plunge closed path
10
Top picker expected to be active picker in plunge
(run-time)
11
Bottom picker expected to be active picker in plunge
(run-time)
12
Bottom thumb expected to be active in plunge home
(powerup)
13
Top thumb expected to be active in plunge home
(powerup)
14
Translate over voltage exceeded limits set by
firmware