2.2
Parts Life Reset Function
This function is used to reset the relevant part counter when the user replaced a periodical
replacement part with the correct procedure, and also used to forcibly reset the relevant part
counter when an error cannot be resolved because the user did not replace a consumable part
with the correct procedure.
(1) Press the 3 and 9 buttons at the same time in the ready state.
Non Touch panel model
(2) The "Reset Menu" will appear on the LCD. Select the applicable periodical replacement
part or consumable part by pressing the
<Periodical replacement parts or consumable part are indicated on the LCD>
- Drum unit
- Belt unit
- PF kit MP
- PF kit 1
- PF kit 2
- Fuser
- Laser
(3) Once "
(4) The machine implements clearing the counter.
Touch panel model
(2) "Reset Menu" and periodical replacement parts or consumable parts will appear on the
LCD. Press the relevant part.
(3) "Reset? Yes/No" will appear on the LCD. Press "Yes".
(4) "Accepted" appears on the LCD, and the counter is cleared.
Note:
- All replacement parts are always indicated on the LCD even though their lives do not
reach the end of life.
- The machine returns to the ready state automatically if no panel operation is implemented
for 30 seconds.
Reset
Exit" appears on the LCD; press
or
button and press the OK button.
5-69
button.
Confidential