Additional Functions - Sartorius LP Models Operating Instructions Manual

Master pro series electronic precision balances
Table of Contents

Advertisement

Additional Functions

Password
You can block access to parameter
settings in the Setup menu and to
the ID-code input function, as well as
to the exact calibration weight, by
assigning a password.
Enter the password by selecting
INPUT in the Setup menu.
See "Configuring the Balance" for
a detailed description.
Protecting Menu Parameters
In the Setup menu, you can define
whether menu parameters are:
– accessible for changes
(alterable, 8 1 1)
– can be read only (readable,
8 1 2)
Acoustic Signal
An acoustic signal is emitted
when you press a key. When the
key pressed is allowed, the signal
is a single beep tone; when it
is not allowed, this is signaled by
a double beep (key does not initiate
a function). In the Setup menu,
you can configure whether
– the acoustic signal should sound
(on, 8 2 1), or
– the acoustic signal should not
sound (off, 8 2 2)
70
Blocking the Keys
When you operate the balance via
an on-line computer, it is advisable
that you block the keys on the
display and control unit. In the Setup
menu, you can configure whether
– the keys are active
(Keys unblocked, 8 3 1),
– the keys are blocked
(Keys blocked, 8 3 2), except
for M and e, or
– the alphanumeric keys
are blocked
(alphanum. blocked, 8 3 3).
Universal Switch for Remote Control
You can connect an external
universal switch to the interface port
of your balance (e.g., a foot switch)
for remote control of the functions
listed below. In the Setup menu,
you can configure which function is
to be controlled via remote switch:
– Printing (Print key funct.,
8 4 1)
– Taring
(Tare key function, 8 4 2)
– Calibration
(CAL key function, 8 4 3)
– Function key
(F key function, 8 4 4)
– Delete/cancel
(CF key function, 8 4 5)
– Toggling
(Toggle key funct., 8 4 6)
Display Backlighting
You can have the display
backlighted for improved readability
of displayed values. In the Setup
menu, you can configure whether the
– display backlighting is on
(on, 8 5 1),
– display backlighting is off
(off, 8 5 2), or
– display backlighting switches off
automatically if there is no change
in the readout for at least 4 minutes
(Auto off aft. 4 min., 8 5 3)
Power-On Mode
You can configure the balance
so that once a power supply is
connected,
– the balance is turned off
(Off/on/standby, 8 6 1
or Off/on, 8 6 2), or
– the balance switches on
automatically (Auto on, 8 6 4)
You can also set the configurations
so that when the balance
is switched off after use, it is
– off – not in balances with
a weighing capacity ≥16 kg
(Off/on, 8 6 2), or
– in the standby mode
(Off/on/standby, 8 6 1)
When you turn on the balance,
a self-test of the functions is run (test
is displayed; the bar graph is shown)
After the self-test has been
completed, the weighing range
of the balance is displayed (line for
metrological data shows different
maximum values)
Automatic Shutoff
When parameter 8 6 2 is selected
in the Setup menu, you can configure
whether
– the balance will shut off
automatically after 4 minutes
without use
(After 4 min., 8 7 1), or
– automatic shutoff is deactivated
(off, 8 7 2)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents