Additional Functions
Password
You can block access to parameter
settings in the Setup menu and to
the ID-code input function, as well as
to the exact calibration weight, by
assigning a password.
Enter the password by selecting
INPUT in the Setup menu.
See "Configuring the Scale" for
a detailed description.
Protecting Menu Parameters
In the Setup menu, you can define
whether menu parameters are:
– accessible for changes
(alterable, 8 1 1)
– can be read only (readable,
8 1 2)
Acoustic Signal
An acoustic signal is emitted
when you press a key. When the
key pressed is allowed, the signal
is a single beep tone; when it
is not allowed, this is signaled by
a double beep (key does not initiate
a function). In the Setup menu,
you can configure whether
– the acoustic signal should sound
(on, 8 2 1), or
– the acoustic signal should not
sound (off, 8 2 2)
Blocking the Keys
When you operate the scale by an
on-line computer, it is advisable that
you block the keys on the display
and control unit. In the Setup menu,
you can configure whether
– the keys are active
(Keys unblocked, 8 3 1),
– the keys are blocked
(Keys blocked, 8 3 2), except
for M and e/[ON/OFF], or
– the alphanumeric keys
are blocked
(alphanum. blocked, 8 3 3).
74
Universal Switch for Remote Control
You can connect an external
universal switch to the interface port
of your scale (e.g., a foot switch)
for remote control of the functions
listed below. In the Setup menu,
you can configure which function is
to be controlled via remote switch:
Remote universal switch
Function
Menu setting
p/[PRINT] key
t key
[ISOTEST]/[TEST] key
v/[FUNCTION] key
c key
w/[TOGGLE] key
See "Pin Assignment Chart."
Display Backlighting
You can have the display
backlighted for improved readability
of displayed values. In the Setup
menu, you can configure whether the
– display backlighting is on
(on, 8 5 1),
– display backlighting is off
(off, 8 5 2), or
– display backlighting switches off
automatically if there is no change
in the readout for at least 4 minutes
(Auto off aft. 4 min., 8 5 3)
Power-On Mode
You can configure the scale
so that once a power supply is
connected,
– the scale is turned off
(Off/on/standby, 8 6 1
or Off/on, 8 6 2), or
– the scale switches on
automatically (Auto on, 8 6 4)
You can also set the configurations
so that when the scale is switched off
after use, it is
– off (Off/on, 8 6 2) – function not
available on FB...-EDE models, or
– in the standby mode
(Off/on/standby, 8 6 1)
When you turn on the scale, a self-
test of the functions is run (test is
displayed; the bar graph is shown).
After the self-test has been
completed, the weighing range
of the scale is displayed (line for
metrological data shows different
maximum values).
Automatic Shutoff
When parameter 8 6 2 is selected
8 4 1
in the Setup menu, you can configure
8 4 2
whether
8 4 3
– the scale will shut off
8 4 4
automatically after 4 minutes
without use
8 4 5
(After 4 min., 8 7 1), or
8 4 6
– automatic shutoff is deactivated
(off, 8 7 2)
Printing an ISO/GMP-compliant
Record
In the Setup menu, you can configure
whether
– no ISO/GMP-compliant record
will be printed (off, 8 10 1),
– an ISO/GMP-compliant record
will be printed after calibration/
adjustment (Only for cal./adj.,
8 10 2), or
– every printout will be an
ISO/GMP-compliant record
(always ON, 8 10 3)
Undoing All Parameter Changes –
Reset Function
There is a factory setting for
each parameter. In the Setup menu,
you can configure whether
– menu factory settings will
be restored after exiting Setup
(Restore, 9 1 1), or
– menu factory settings will not
be restored after exiting Setup
(Do not restore, 9 1 2)