Additional Functions - Sartorius FB Operating Instructions Manual

Factory series electronic precision scales
Table of Contents

Advertisement

Additional Functions

Password
You can block access to parameter
settings in the Setup menu and to
the ID-code input function, as well as
to the exact calibration weight, by
assigning a password.
Enter the password by selecting
INPUT in the Setup menu.
See "Configuring the Scale" for
a detailed description.
Protecting Menu Parameters
In the Setup menu, you can define
whether menu parameters are:
– accessible for changes
(alterable, 8 1 1)
– can be read only (readable,
8 1 2)
Acoustic Signal
An acoustic signal is emitted
when you press a key. When the
key pressed is allowed, the signal
is a single beep tone; when it
is not allowed, this is signaled by
a double beep (key does not initiate
a function). In the Setup menu,
you can configure whether
– the acoustic signal should sound
(on, 8 2 1), or
– the acoustic signal should not
sound (off, 8 2 2)
Blocking the Keys
When you operate the scale by an
on-line computer, it is advisable that
you block the keys on the display
and control unit. In the Setup menu,
you can configure whether
– the keys are active
(Keys unblocked, 8 3 1),
– the keys are blocked
(Keys blocked, 8 3 2), except
for M and e/[ON/OFF], or
– the alphanumeric keys
are blocked
(alphanum. blocked, 8 3 3).
74
Universal Switch for Remote Control
You can connect an external
universal switch to the interface port
of your scale (e.g., a foot switch)
for remote control of the functions
listed below. In the Setup menu,
you can configure which function is
to be controlled via remote switch:
Remote universal switch
Function
Menu setting
p/[PRINT] key
t key
[ISOTEST]/[TEST] key
v/[FUNCTION] key
c key
w/[TOGGLE] key
See "Pin Assignment Chart."
Display Backlighting
You can have the display
backlighted for improved readability
of displayed values. In the Setup
menu, you can configure whether the
– display backlighting is on
(on, 8 5 1),
– display backlighting is off
(off, 8 5 2), or
– display backlighting switches off
automatically if there is no change
in the readout for at least 4 minutes
(Auto off aft. 4 min., 8 5 3)
Power-On Mode
You can configure the scale
so that once a power supply is
connected,
– the scale is turned off
(Off/on/standby, 8 6 1
or Off/on, 8 6 2), or
– the scale switches on
automatically (Auto on, 8 6 4)
You can also set the configurations
so that when the scale is switched off
after use, it is
– off (Off/on, 8 6 2) – function not
available on FB...-EDE models, or
– in the standby mode
(Off/on/standby, 8 6 1)
When you turn on the scale, a self-
test of the functions is run (test is
displayed; the bar graph is shown).
After the self-test has been
completed, the weighing range
of the scale is displayed (line for
metrological data shows different
maximum values).
Automatic Shutoff
When parameter 8 6 2 is selected
8 4 1
in the Setup menu, you can configure
8 4 2
whether
8 4 3
– the scale will shut off
8 4 4
automatically after 4 minutes
without use
8 4 5
(After 4 min., 8 7 1), or
8 4 6
– automatic shutoff is deactivated
(off, 8 7 2)
Printing an ISO/GMP-compliant
Record
In the Setup menu, you can configure
whether
– no ISO/GMP-compliant record
will be printed (off, 8 10 1),
– an ISO/GMP-compliant record
will be printed after calibration/
adjustment (Only for cal./adj.,
8 10 2), or
– every printout will be an
ISO/GMP-compliant record
(always ON, 8 10 3)
Undoing All Parameter Changes –
Reset Function
There is a factory setting for
each parameter. In the Setup menu,
you can configure whether
– menu factory settings will
be restored after exiting Setup
(Restore, 9 1 1), or
– menu factory settings will not
be restored after exiting Setup
(Do not restore, 9 1 2)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents