Novatel MiLLennium OM-20000040 User Manual page 79

Glonass gpscard
Table of Contents

Advertisement

F.3.3 CABLES
Please see the following sections for the technical specifications of all cables and optional accessories. For field
replacement of the LEMO connectors, and to find part numbers of optional accessories, please see Appendix K,
Page 126.
F.3.3.1 Input Power Cables
The following cables allow you to power the PowerPak II enclosure from either an AC source, an automotive DC
source or a battery.
Cigarette-lighter power adapter with replaceable 3 amp slow-blow fuse, see section F.3.3.1.1
for a drawing of the cable (NovAtel part number 01014989)
Optional auto-ranging AC/DC converter, and AC power cord, see section F.3.3.1.2 for more
information (NovAtel part number GPS-APWR)
F.3.3.1.1 Cigarette-Lighter Power Adapter (NovAtel part number 01014989)
The cigarette-lighter power adapter included with the PowerPak II supplies +12 V DC while operating from an
automotive source. On the end of the cord which is inserted into the PowerPak II there is a retaining nut; it threads
onto the socket to keep the plug from accidentally being pulled out. A replaceable 3 amp fuse is built into the
assembly which is inserted into the cigarette lighter.
Reference
Description
1
Cigarette lighter adapter
2
Retaining nut
F.3.3.1.2 Optional AC to DC Power Converter (NovAtel part number GPS-APWR)
An optional AC to DC power converter is available for the PowerPak II, which allows you to operate the unit from
an AC outlet. The converter is autoranging to accommodate standard line voltages (110 to 220 V AC) and
frequencies (50 to 60 Hz). It features a retaining nut on the connector that is inserted into the PowerPak II; when
threaded onto the socket, it prevents the plug from accidentally being pulled out. Its output voltage is compatible
with the PowerPak II's requirements. For replacement purposes, the NovAtel part number is GPS-APWR.
F.3.3.2 Serial Data Cables
The RS232C Y-type null-modem cable, 10-pin LEMO plug to 9-pin D-connector (DE9S socket), is used to connect
the receiver to a serial (RS232C) communication port on a terminal or computer. Its NovAtel part number is
60715062. Please see section F.3.3.2.1 for a drawing of this cable.
GPS/GLONASS Receiver User Manual Rev 1
1
F PowerPak II Enclosure
2
79

Advertisement

Table of Contents
loading