Measurement Circuits; When Not Passing Signal Through Divider Circuit On Rx Fil Board - Furuno FS-1575 Service Manual

Ssb radiotelephone
Hide thumbs Also See for FS-1575:
Table of Contents

Advertisement

5.8.2 Measurement Circuits

Signal receiving paths vary with system settings. For details, refer to information on
page 4-73.

1. When not passing signal through DIVIDER circuit on RX FIL board

To TX FIL p.c.b -> J3: RX RF
To R.ANT
J8. DUP IN
J7. BPF OUT
To RX p.c.b -> J2: ANT RX
Fig. 5.8.1 FS-1575, -2575, -5075
1.1) When receiving from [T/R ANT]: FS-1575, -2575, -5075
Setting Procedure
[MENU] -> 9. SERVICE -> 3. RT SETUP -> 1. SETUP -> RX ANT
[MENU] -> 5. SYSTEM -> 7. RX SETUP -> 2. ANT SELECT
[MENU] -> 9. SERVICE -> 3. RT SETUP -> 1. SETUP -> DIVIDER
1.2) When receiving from [T/R ANT]: FS-1575, -2575, -5075
Setting Procedure
[MENU] -> 9. SERVICE -> 3. RT SETUP -> 1. SETUP -> RX ANT
[MENU] -> 5. SYSTEM -> 7. RX SETUP -> 2. ANT SELECT
[MENU] -> 9. SERVICE ->3. RT SETUP -> 1. SETUP -> DIVIDER
1.3) When receiving from [R. ANT]: FS-1575, -2575, -5075
Setting Procedure
[MENU] -> 9. SERVICE -> 3.RT SETUP -> 1.SETUP -> RX ANT
[MENU] -> 5.SYSTEM -> 7.RX SETUP -> 2.ANT SELECT
[MENU] -> 9.SERVICE -> 3.RT SETUP -> 1.SETUP -> DIVIDER
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
RX FIL
J8. DUP IN
J7. BPF OUT
5-56
5.8 Reception Testing
To TX FIL p.c.b -> J3: RX RF
To R.ANT
L=80
L=80
J2. SIMP OUT
L=80
J1. DUP IN
J3. DUP OUT
To RX p.c.b -> J2: ANT RX
Fig. 5.8.2 FS-5075 DUPLEX
Setting
DISCONNECT
Not allowed
OFF
Setting
CONNECT
TRX ANT
OFF
Setting
CONNECT
RX ANT
OFF
RX FIL
DUP FIL