Furuno FS-1575 Service Manual

Furuno FS-1575 Service Manual

Ssb radiotelephone
Hide thumbs Also See for FS-1575:
Table of Contents

Advertisement

SERVICE MANUAL
Ku-BAND VSAT
SSB RADIOTELEPHONE
FV-100
FS-1575/2575/5075
MODEL
CONFIDENTIAL for Internal Use Only
This document is only for a service staff of FURUNO products.
Any unauthorized reproduction of any of its content is prohibited.
www.furuno.co.jp

Advertisement

Table of Contents
loading

Summary of Contents for Furuno FS-1575

  • Page 1 SERVICE MANUAL Ku-BAND VSAT SSB RADIOTELEPHONE FV-100 FS-1575/2575/5075 MODEL CONFIDENTIAL for Internal Use Only This document is only for a service staff of FURUNO products. Any unauthorized reproduction of any of its content is prohibited. www.furuno.co.jp...
  • Page 2 Nishinomiya, 662-8580, JAPAN A : JUN 2012 Printed in Japan All rights reserved. B : NOV . 26, 2012 Pub. No. SME-56770-B *00017687610* *00017687610* (NAYO ) FS-1575/2575/5075 *00017687610* *00017687610* * 0 0 0 1 7 6 8 7 6 1 0 *...
  • Page 3: Table Of Contents

    1.3.4 Reception of DSC Message ································································ 1-16 1.3.5 Audio Alarms ······················································································· 1-17 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 4 3) SW board (16P0212) ·············································································· 2-64 2.7.2 IB-585 ···································································································· 2-65 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 5 4.3.5 [5. DATE/TIME] ····················································································· 4-18 4.3.6 [6. TIME OUT] ······················································································· 4-19 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 6 5. DSC/DSE SENTENCE (ON, OFF) ························································· 4-59 6. LAST DISTRESS LOG ··········································································· 4-60 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 7 4.14.4 Making Setting of “F6: System” Menu ··············································· 4-101 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 8 2. Output power measurement by 1-tone signal ········································· 5-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 9 5.7.6 COUP: 05P0875 (FS-2575 and FS-5075) ············································· 5-54 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 10 13. FILTER VR ····························································································· 6-19 14. FILTER ALC···························································································· 6-19 viii CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 11 11. ALARM UNIT ·························································································· 6-39 12. REMOTE ································································································ 6-40 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 12 6.9.3 Troubleshooting for TUNE NG ······························································ 6-59 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 13 6. TX FIL board: (FS-1575, -2575, -5075) ···················································· 6-84 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 14 3. PROTECT signal (FS-2575 and FS-5075) ··············································· 7-36 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 15 3. SW REG (05P0873): FS-2575 and FS-5075 ········································· 7-67 xiii CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 16 1. Verifying IB-583 program version ····························································· 8-13 2. IB-583 updating program ·········································································· 8-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 17 Q30. Which of the GNSS and Manual modes is given priority to enter data? ······ 9-5 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 18 Q60. Are front and rear handsets the same in the MIC gain? ···························· 9-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 19 AP1.5.8 Verifying Version of General Menu Manager ······························· AP1-25 xvii CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 20 IB-585 ················································································································· E-8 Contents of Drawings ······································································ S0-1 xviii CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 21: Summary

    Furthermore, describe antenna type, length, and lead-in length without fail. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 22: Optional Operation

    The password “XXXXXX” is the same as that for the FS-xx70 series. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 23: Software

    C-CPU, 40 seconds after turning ON the power. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 24: Settings

    - Select [MENU] -> 9.SERVICE -> 3.RT SETUP -> 1.SETUP -> DIVIDER -> “OFF.” CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 25: Tx Output Power Check And Adjustment

    If no problems, it is advisable to reduce power by 10% to 20%. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 26: Frequency Adjustment

    3.RT SETUP -> 4.TX PWR (FREQ) -> “DSC.” CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 27: Replacement Of Boards

    Make settings of J4 (ANT BK) 05P0883 COUP and J5 (ANT GND). CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 28: Checks List

    If T/R antenna is of the self-supporting type, are elements securely 1.21 mounted? CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 29 Slave Delay? IB-583 -> 8msec, IB-585 -> 12msec CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 30 16M : 18M : 22M : 25M : CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 31: Comprehensive Tests

    Date / Time Result Station Voice NBDP CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 32: Chapter 1. Overview

    RX-only antenna or shared use of T/R antenna CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 33: System Configuration

    Fig. 1.1.1 FS-2575 and -5075 System Configuration Diagram CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 34: Fs-1575 System Configuration

    PR-300 Fig. 1.1.2 FS-1575 System Configuration Diagram CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 35 Used to give priority to SPEAKER 4Ω/5W external speaker (φ3.5 jack) CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 36: Installations

    [MENU] -> 9. SERVICE -> 3. RT SETUP -> 1. SETUP -> Set DIVIDER to “ON” CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 37: Full-Duplex Communications

    Option Fig. 1.2.1 Example of Antenna Wiring CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 38: Selection Of Power Supply Cable

    Cable length (m) Fig. 1.2.2 Voltage Drops in Cables:5% CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 39: Positional Data

    CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 40: Operations

    Turns ON (in Green) when 24 V power is supplied to FS-xx75T. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 41: Overview Of Display

    On the DSC window and the MENU window, appears when the emission type is set to “FAX”. 1-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 42: Tab/Guide Area

    User option Tab: Procedure being initiated 1-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 43 UNABLE ACK creation window. 1-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 44: Overview Of Rt Window

    - ROUTINE SCAN Stop : [SCAN ] 1-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 45: Overview Of Dsc Window

    : Transmits at a specified frequency out of 2M to 16M band five times. 1-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 46: Transmission Of Distress Alert

    3.5 - 4.5 min. 3.5 - 4.5 min. 1-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 47: Reception Of Dsc Message

    If WR2 is not incorporated, DSC general messages are received on the “RT.” 1-16 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 48: Audio Alarms

    2200 Hz and 0 Hz (500 ms) 1-17 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 49: Chapter 2. Parts Location

    [PRINTER] [TRANSCEIVER] Fig. 2.1.2 Rear panel view CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 50 Fig. 2.1.5 Rear panel, C-CPU board removed CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 51 Fig. 2.1.7 Front panel, PANEL board removed SP: S50U33-K0014A (10W/4Ω) Fig. 2.1.8 Speaker CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 52 U4: 256Mbit SDRAM Fig. 2.1.10 C-CPU board: 05P0852 (B-side) CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 53 Fig. 2.1.12 C-IF board: 05P0853 (B-side) Fig. 2.1.13 PANEL board: 05P0844 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 54: Transceiver Unit: Fs-1575T

    LAN port Fig. 2.2.2 FS-1575T, bottom view CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 55 Fig. 2.2.4 FS- 1 575T, door opened CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 56 J8: EXT ALM setting Fig. 2.2.5 FS-1575T, shield cover removed CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 57 PA-IF: 05P0864A Fig. 2.2.6 FS-1575T, heat sink side CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 58 Fig. 2.2.7 FS- 1 575T, mounting board (A-side) 2-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 59 Fig. 2.2.8 FS-1575T, mounting board (B-side) 2-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 60: Transceiver Unit: Fs-2575T

    [REMOTE] Fig. 2.3.2 FS-1575T, bottom view 2-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 61 05P0861 Fig. 2.3.4 FS-2575T, door opened 2-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 62 2.3 Transceiver Unit: FS-2575T Fig. 2.3.5 FS-2575T, PCB LAYOUT 2-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 63 Fig. 2.3.6 FS-2575T, shield cover removed 2-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 64 Fig. 2.3.7 FS-2575T, heat sink side 2-16 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 65 Fig. 2.3.8 FS-2575T, mounting board (A-side) 2-17 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 66 Fig. 2.3.9 FS-2575T, mounting board (B-side) 2-18 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 67: Transceiver Unit Fs-5075T

    [REMOTE] Fig. 2.4.2 FS-5075T, bottom view 2-19 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 68 PCB LAYOUT Fig. 2.4.4 FS-5075T, door opened 2-20 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 69 2.4 Transceiver Unit FS-5075T Fig. 2.4.5 FS-5075T, PCB LAYOUT 2-21 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 70 Fig. 2.4.6 FS-5075T, shield cover removed 2-22 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 71 Fig. 2.4.7 FS-5075T, heat sink side 2-23 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 72 Fig. 2.4.8 FS-5075T, DRV board removed 2-24 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 73 Fig. 2.4.10 FS-5075T, RX-FIL and DUP FIL board 2-25 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 74: Board

    Fig. 2.5.2 TX-FIL board (05P0876) B-side 2-26 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 75: Tx Fil Board: 05P0870B (Fs-2575)

    Fig. 2.5.4 TX-FIL board (05P0870B) B-side 2-27 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 76: Tx Fil Board: 05P0870A (Fs-5075)

    05P0870A: J2, JP1 not mounted 05P0870B: J1, not mounted 2-28 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 77: Comb Board: 05P0869 (Fs-5075)

    Fig. 2.5.8 COMB board (05P0869) B-side 2-29 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 78: Pa Board: 05P0868 (Fs-1575)

    Fig. 2.5.10 PA board (05P0868) B-side 2-30 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 79: Pa Board: 05P0867B (Fs-2575)

    Fig. 2.5.12 PA board (05P0867B) B-side 2-31 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 80: Pa Board: 05P0867A (Fs-5075)

    Fig. 2.5.14 PA board (05P0867A) B-side 2-32 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 81: Drv Board: 05P0866B (Fs-2575)

    Fig. 2.5.16 DRV board (05P0866B) B-side 2-33 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 82: Drv Board: 05P0866A (Fs-5075)

    Fig. 2.5.18 DRV board (05P0866A) B-side 2-34 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 83: Tx Board: 05P0856 (Fs-1575, Fs-2575, Fs-5075)

    Fig. 2.5.20 TX board (05P0856) B-side 2-35 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 84: Pa-If Board: 05P0864 (Fs-2575, Fs-5075)

    Fig. 2.5.22 PA-IF board (05P0864) B-side 2-36 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 85: Pa-If Board: 05P0864A (Fs-1575)

    Fig. 2.5.24 PA-IF board (05P0864A) B-side 2-37 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 86: Rx-Fil Board: 05P0862B (Fs-1575, Fs-2575)

    Fig. 2.5.26 RX-FIL board (05P0862B) B-side 2-38 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 87: Rx-Fil Board: 05P0862A (Fs-5075)

    Fig. 2.5.28 RX-FIL board (05P0862A) B-side 2-39 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 88: Dup-Fil Board: 05P0863 (Fs-5075)

    Fig. 2.5.30 DUP-FIL board (05P0863) B-side 2-40 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 89: Rx Board: 05P0842 (Fs-1575, Fs-2575, Fs-5075)

    Fig. 2.5.32 RX board (05P0842) B-side 2-41 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 90: Wr1 Board: 05P0847A (Fs-1575, Fs-2575, Fs-5075)

    Fig. 2.5.34 WR1 board (05P0847A) B-side 2-42 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 91: Wr2 Board: 05P0847B (Fs-1575, Fs-2575, Fs-5075)

    Fig. 2.5.36 WR2 board (05P0847B) B-side 2-43 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 92: T-If Board: 05P0861 (Fs-2575, Fs-5075), 05P0861A (Fs-1575)

    Fig. 2.5.38 T-IF board (05P0861A) B-side 2-44 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 93: Mot Board: 05P0860 (Fs-1575, Fs-2575, Fs-5075)

    Fig. 2.5.40 MOT board (05P0860) B-side 2-45 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 94: T-Cpu Board: 05P0859 (Fs-1575, Fs-2575, Fs-5075)

    Fig. 2.5.42 T-CPU board (05P0859) B-side 2-46 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 95: Sw-Reg Board: 05P0873 (Fs-2575, Fs-5075)

    Fig. 2.5.44 SW-REG board (05P0873) B-side 2-47 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 96: Pwr Board: 05P0874 (Fs-1575, Fs-2575, Fs-5075)

    Fig. 2.5.46 PWR board (05P0874) B-side 2-48 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 97: P-Sw Board: 05P0871 (Fs-1575, Fs-2575, Fs-5075)

    Fig. 2.5.48 P-SW board (05P0871) B-side 2-49 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 98: Fet Board: 05P0872 (Fs-5075)

    Fig. 2.5.50 FET board (05P0872) B-side 2-50 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 99: Antenna Coupler

    Fig. 2.6.1 AT-5075 2.5mm: 8kV Fig. 2.6.2 Arrester 2-51 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 100 Fig. 2.6.4 COUP board (05P0875 ) B-side 2-52 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 101 Fig. 2.6.5 COUP board terminal area 2-53 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 102 Fig. 2.6.7 ATU GND, Drain tube 2-54 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 103: At-1575

    Fig. 2.6.8 AT-1575-AES Weight: 8.8kg Fig. 2.6.9 AT-1575-SUS 2-55 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 104 Fig. 2.6.10 AT-1575-AES 2mm: 6kV Fig. 2.6.11 Arrester 2-56 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 105 Fig. 2.6.12 AT-1575-SUS 2mm: 6kV Fig. 2.6.13 Arrester 2-57 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 106 Jumper: J4 #2 – J4 #4 Fig. 2.6.14 COUP board (05P0883) 2-58 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 107: Nbdp Terminal

    Power SW Fig. 2.7.1 IB-583 Overview 2-59 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 108 Fig. 2.7.3 FDD connector - 2 2-60 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 109 Fig. 2.7.5 J6 flat cable - 3 2-61 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 110 LCD unit (LCD:NL6448BC33-46) Fig. 2.7.6 Panel 2-62 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 111: Term Cpu (16P0209A)

    Fig. 2.7.7 TERM CPU board (16P0209A) 2-63 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 112: Pwr Board (16P0211A)

    (Distress button for FELCOM15) Fig. 2.7.9 SW board (16P0212) 2-64 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 113 Key board Fig. 2.7.10 IB-585 Overview 2-65 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 114 LCD panel Fig. 2.7.12 boards removed 2-66 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 115 Fig. 2.7.14 Mounting chassis of LCD panel Fig. 2.7.15 LCD panel 2-67 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 116 Fig. 2.7.17 TERM CPU board ( 16P0283A ) B-side 2-68 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 117 Fig. 2.7.20 SD USB board ( 16P0289 ) 2-69 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 118: Handset: Hs

    ON/OFF hook detector) Fig. 2.8.2 Handset Hanger 2-70 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 119: Ac/Dc Power Supply Unit

    VR1: over current VR2: output power 2-71 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 120 100V: 10A Output:20A 220V: 5A 2-72 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 121 Input power Fuse: 2A Output Voltage ADJ. 2-73 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 122: Chapter 3. Menu Tree

    The service mode will be canceled three minutes after exiting from the service menu. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 123: Menu Tree

    CH: 1-29/00-99 TX FREQ: xxxxx.x RX FREQ: xxxxx.x CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 124 5. DATE/TIME DATE dd/mm/yyyy TIME xx:xx UTC CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 125 8. EXTERNAL 2. SAFETY ALARM 3. ROUTINE CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 126 DSC FREQ: 2 – 16M DIS/SAF FREQ FAIL NAME: CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 127 - MF: 6. DISTRESS SCAN -> Deleted ON/OFF ON/OFF CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 128 8. ALARM Displays alarm currently in progress. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 129 (200Hz) TX TUNE COUPLER RCVD THROUGH DIFF CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 130 1100/1700Hz 1785Hz 1785Hz 700/1700Hz <LOAD DEFAULT> YES/NO CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 131 Return to factory settings, except MMSI, MAC address, FACTORY and adjusted values. SETTINGS 3-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 132 78K APP 01.xx.20xxxxxx 0550247-01.xx 78K BOOT 3-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 133 0, 1-- 0, 1-- 0, 1-- 3-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 134 HOOK ON/OFF OFF/ON [LCD TEST] (4/4) 3-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 135 4. POWER ON LOG 5. INFORMATION LOG 3-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 136 SOFTWARE ERASE [for DEVELOP] DEBUG MODE 3-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 137: Chapter 4. System Setting

    DSC- and RT-related system settings and a more 4-49 detailed maintenance menu. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 138: Special Operation

    [MENU] -> 9.SERVICE -> 2.DSC SETUP. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 139: Mmsi Setting And Clear All

    When MMSI is already registered, overwrite the MMSI. To exit this window, press the [CANCEL] key. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 140: Mmsi Clear

    Subsequently, a message saying “Initializing…” will appear and the RT window will open. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 141: User Ch

    TX POWER (USER CH) Call from NBDP Terminal CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 142: User Ch Window Operation

    2. Press the [5]: ENTRY key. The “USER CH ENTRY” window will appear. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 143 Repeat the procedure aforementioned to register all other channels. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 144: Displaying A List Of User Ch Registered [6]: List

    Click “YES,” and then press the [ENTER] knob. All channels will be deleted. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 145: Editing User Ch Registered

    “RT” window to reflect the channel selected on the RT window. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 146: System

    <VIEW> HOST NAME (depending on model) 4-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 147: Sq Freq]

    1.5-s delay time is provided to close it. 4-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 148: Key Assign]

    CLARIFIER is enabled in SSB, CW, and LSB MODE. 4-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 149: Print]

    [MENU] -> 1.TEST -> 1.DAILY TEST 4-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 150 [MENU] -> 9.SERVICE -> 3.RT SETUP -> 2.SELF CHECK 4-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 151 Sample: Send DISTRESS ALERT Message Sample: Received DISTRESS ALERT Message 4-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 152: Position]

    However, GNS sentences from any talker other than GP, GL, GN, and GA are not received. 4-16 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 153 Priorities of formatters: GNS > GGA > RMC > GLL 4-17 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 154: Date/Time]

    • IEC: Not allow for the use of RMC time as system time. 4-18 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 155: Time Out]

    NO TIMEOUT. 4-19 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 156 Submenu-1 “8. CW” will be added. 4-20 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 157: Rx Setup]

    RT SETUP -> 1.SETUP -> “LINE OUT.” The adjustment range is 0 dBm ± 10 dBm/ 600Ω. 4-21 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 158: Ant Select (Rx Ant, Trx Ant)

    RX FIL Fig. 4.3.1 ANT SELECTOR 4-22 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 159: Clarifier (On, Off)

    DDS frequency data of 1st LO on the RX board. 4-23 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 160: External Alarm]

    FS-2575C is given the top priority. 4-24 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 161 2 − 3: NORMAL CLOSE Fig. 4.3.2 EXTERNAL ALARM I/F 4-25 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 162: Network]

    • FS-2575: SSB004 • FS-5075: SSB005 4-26 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 163: Dsc

    -> 9. SERVICE -> 2. DSC SETUP -> CLASS, the frequency will be fixed to 2187. 5kHz.” 4-27 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 164: Address Book]

    [CANCEL]: BACK Returns to the previous window. 4-28 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 165: Registering An Address [5]: Entry

    [ENTER] knob. 4-29 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 166: Displaying A List Of Addresses Registered [6]: List

    [6]: Switched by LIST Key 4-30 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 167: Deleting Address(S) Registered [4]: Delete

    The content of the address selected will be replaced with that edited. 4-31 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 168: Reflecting Selected Address On Dsc Compose Message Window

    Indicates that data has come from the address book. 4-32 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 169: Msg File]

    “TO” data entry column. [DSC MSG]: COMPOSE 4-33 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 170: Registering A Dsc Message [5]: Entry

    [ENTER] knob. With this, the registration of a single MESSAGE FILE is completed. 4-34 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 171: Displaying A List Of Dsc Messages Registered [6]: List

    Click “YES,” and then press the [ENTER] knob. All message files will be cleared. 4-35 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 172: Editing Dsc Message Registered [Enter]: Detail

    To transmit this message, click on “GO TO CALL,” and then press the [ENTER] knob. 4-36 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 173: Ack Settings]

    ITU-R MANUAL M.493-11. 4-37 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 174 [TAB] key. 4-38 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 175: Special Msg]

    CIRCLE or QUADRANT. 4-39 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 176: Routine Scan]

    Turning the [ENTER] knob allows for the selection of scanning frequency being stopped. 4-40 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 177: Distress Scan]

    DSC Distress and Safety frequency to the scanning frequency of ROUTINE Scan table. 4-41 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 178 HOOK SP. Enter “652111.” Select to “DISTRESS.” 4-42 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 179: Audio

    75 dBA to 85 dBA at a distance of 1 meter from a sound source. 4-43 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 180: Key Click]

    For details, refer to information on page 4-42. 4-44 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 181: Ordinary Alarm]

    ON/OFF setting of external alarm sound output. 4-45 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 182: Alarm Distance]

    MSG after LOG. receiving DIS 4-46 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 183 500NM. 4-47 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 184: Side Tone]

    For details, refer to information on page 6-20. 4-48 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 185: Service

    Subsequently, select on “9. SERVICE,” and then enter the password: XXXXXX. Enter the password. Spanner Mark 4-49 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 186: Equip Type

    4-83 to 4-86 SOFTWARE ERASE DEBUG MODE 4-50 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 187 If this function gets activated, a popup message saying “CH BUSY!” will be outputted. 4-51 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 188: Distress Alarm (0 - 31)

    Do not make unnecessary changes to the alarm sound level setting. 4-52 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 189: Class (Mf, Mf/Hf, Non-Gmdss)

    MF, MF/HF Mode: Main Menu NON-GMDSS Mode: Main Menu 4-53 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 190 MMSI information will be put into a nonregistered state. 4-54 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 191 “Unread icon” on the window. 4-55 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 192 [RADIO TELEPHONE] is displayed in place. RADIO TELEPHONE RADIO TELEPHONE 4-56 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 193 Disables the [DISTRESS] key not to allow for the transmission of Distress alerts. 4-57 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 194 4-58 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 195: Dsc/Dse Sentence (On, Off)

    (Expanded DSC message) IEC61162-1 port: Betwseen TB6 #1-2 4-59 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 196: Last Distress Log

    4 seconds, enter the password: XXXXXX, and then click on “CLEAR ALL.” 4-60 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 197: Rt Setup]

    (Except limit frequency) MARINE/USER ITU/USER USER 4-61 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 198 16806.5 (MSI-HF) 19680.5 (MSI-HF) 22376.0 (MSI-HF) 26100.5(MSI-HF) 4-62 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 199 For distress and Safety communications! [CANCEL]: Close window 4-63 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 200 4125.0 1200 12290.0 6215.0 1600 16420.0 4-64 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 201: Am Mode (Rx Only, Tx/Rx)

    CALL frequency of “H2B/2331.5 kHz” will be allowed. 4-65 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 202: Cw (Enable, Disable)

    Setting LSB to “ENABLE” will add a submenu “LSB” on the MODE popup window on the RT window. 4-66 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 203: Selcall (Enable, Disable)

    #13: LINE_IN _C #14: REM_TX KEY_N #7: GND 4-67 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 204: Ref Osc (-127~+127): 0

    For the set value of the clarifier, DDS frequency data of 1st Lo on the RX board is changed and displayed. 4-68 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 205: Tx Tune (On, Off)

    Connect a jumper cable between #7-#9 of TB6 4-69 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 206: Coupler Through (Off, Rcvd, Diff)

    1.2 MHz away from the transmission frequencies. 4-70 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 207: Rx Ant (Connect, Disconnect)

    RX GND RX GND Fig. 4.7.3 4-71 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 208 RX GND RX GND Fig. 4.7.7 4-72 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 209 [MENU] -> 9.SERVICE -> 4.RT SETUP -> 1.SETUP -> DIVIDER -> ON 4-73 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 210 [MENU] -> 9.SERVICE -> 4.RT SETUP -> 1.SETUP -> DIVIDER -> ON 4-74 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 211 [MENU] -> 9.SERVICE -> 4.RT SETUP -> 1.SETUP -> DIVIDER -> ON 4-75 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 212 DUP FIL board is incorporated, RX ANT is set to “ON” and DUP is set to “CH.” 4-76 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 213 DUP FIL board is incorporated, RX ANT is set to “ON” and DUP is set to “CH.” 4-77 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 214 DUP FIL board is incorporated, RX ANT is set to “ON” and DUP is set to “CH.” 4-78 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 215: Divider

    4-79 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 216: Mif (Rs-232C, Rs-485)

    CHI04001) 0=SIMPLEX, 1=SEMI-DUPLEX, DUP MODE 2=FULL-DUPLEX 4-80 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 217 -> [REMOTE] - #21/#22(TD-A/B), #23/ #24(RD-A/B) 4-81 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 218: Restore Factory Settings]

    For details, refer to information on page 6-42. 4-82 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 219: Other]

    Distress Alert button on the IC-350. A distress alert reception alarm is also outputted. 4-83 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 220 NAVTEX SEL N.C. (NX-700) N.O. (NX-500) VERCHK 4-84 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 221 FS-xx70 J204 J203 J205 FS-xx70 FS-xx75 4-85 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 222: P-Browser

    This mode is used by R & D and displays debug information, mainly a TIMEOUT counter. 4-86 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 223: Mounting Of Wr2 Board

    Fig. 4.8.1 WR2 Cable Connection -1 4-87 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 224: To Share With T/R Ant

    Fig. 4.8.2 WR2 Cable Connection -2 4-88 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 225: To Share With Rx Ant (For Duplex Communication)

    Fig. 4.8.3 WR2 Cable Connection -3 4-89 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 226: Wr1 And Wr2 Board Jumper Setting

    J3: [ACTIVE] 1-2: Active (+12V) 2-3: Wire 4-90 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 227: External Alm Output Setting (N.c, N.o)

    Fig. 4.10.1 EXTERNAL ALARM I/F Circuit 4-91 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 228: Mounting Of Dup Fil Board

    To RX p.c.b -> J2: ANT RX 4-92 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 229 Fig. 4.12.1 AT-5075 Jumper Setting Circuit 4-93 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 230 Fig. 4.12.3 Connection between FS-2570 and AT-5075 4-94 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 231 Fig. 4.13.1 AT-1575 Jumper Setting Circuit 4-95 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 232: At-1575 Setting

    Fig. 4.13.2 Connection between FS-1570 and AT-1575 4-96 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 233: Setting

    Enter the changed password in capital letter. (in “caps lock” mode). 4-97 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 234: Making Setting Of Submenu

    9. Select ID Entry (9 digit) 4-98 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 235 The registered answerback code will be deleted. Re-register the answerback code following the procedure specified above. 4-99 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 236 The registered ID number will be deleted. Re-register the ID number following the procedure specified above. 4-100 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 237: Making Setting Of "F6: System" Menu

    It can be arbitrarily set in the range of 0 to 50 msec, but leave the setting as default. “8 msec” 4-101 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 238 Cyan L-Magenta L-White Magenta Yellow Brown 4-102 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 239: Making Printer And Language Setting

    (according to the shift code Russian received). 4-103 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 240: Making Brightness Setting

    3) Hold down the [Shift] key and press the [↓] key. 4-104 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 241: Checking Detailed Software Version

    3) Hold down the [Alt] and [Fn] keys and press the [F1] key. Detailed version will be displayed. 4-105 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 242: List Of Ib-583 Menus

    0: Go to Line Format A: Change Text 4-106 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 243: Setting

    To incorporate the set value saved to the SD card in the IB-585, execute “Import Settings.” 4-107 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 244: Making Setting Of Submenu

    8: Select ID Entry (9 digit) 4-108 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 245 The registered answerback code will be deleted. Re-register the answerback code following the procedure specified above. 4-109 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 246 The registered ID number will be deleted. Re-register the ID number following the procedure specified above. 4-110 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 247: Making Setting Of "F6: System" Menu

    To return the “System” setting to the factory set, put the cursor on [Default], and then press the [Enter] key. 4-111 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 248 • Abort: Termination the line upon forced end due to the operation of the control unit. 4-112 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 249 Combinations with the same foreground and background colors are not allowed. 4-113 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 250: Switching Between English And Russian Modes

    Import Settings Error Count Disp None 4-114 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 251 Do not edit the file. Editing the file with incorrect data will disable normal operation. 4-115 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 252: Making Brightness Setting

    SD card are allowed. 4-116 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 253: Special Operation

    “ABC-- YZ123---890-?().,’=/+ABCD----UVW” 4-117 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 254: Checking Detailed Software Version

    Hold down the [Alt] and [F11] keys to display the version information for developers. 4-118 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 255: List Of Ib-585 Menus

    SD Card Text B: New Macro 4-119 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 256: Ac/Dc Power Unit Setting

    Fig. 4.16.1 PR-850A Input Power Supply Voltage 4-120 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 257 Fig. 4.16.2 PR-300 Input Voltage Setting 4-121 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 258: Chapter 5. Adjustment And Measurement

    SEL CALL power data. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 259 6MHz–25MHz 25MHz-27MHz 27MHz-30MHz TUNE PWR SEL CALL CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 260 FS-5075 system in the MF band is 400W+0/−1.5dB. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 261: Output Power Characteristics

    ● : 4.2MHz, 1500Hz 1-toneMOD. : 4.2MHz, 1100/1700Hz 2-tone MOD. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 262: Fs-5075: Rt Output Power Vs. Pa Ic

    ● : 4.2MHz, 1500Hz 1-tone MOD. : 4.2MHz, 1100/1700Hz 2-tone MOD. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 263: Fs-2575: Power Data Vs. Rt Output Power

    ● : 4.2MHz, 1500Hz 1-tone MOD. : 4.2MHz, 1100/1700Hz 2-tone MOD. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 264: Fs-2575: Rt Output Power Vs. Pa Ic

    ● : 4.2MHz, 1500Hz 1-tone MOD. : 4.2MHz, 1100/1700Hz 2-tone MOD. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 265: Fs-1575: Power Data Vs Rt Output Power

    ● : 4.2MHz, 1500Hz 1-tone MOD. △: 4.2MHz, 1100/1700Hz 2-tone MOD. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 266: Fs-1575: Rt Output Power Vs Pa Ic

    ● : 4.2MHz, 1500Hz 1-tone MOD. △: 4.2MHz, 1100/1700Hz 2-tone MOD. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 267: Fs-2575: Rt Output Power Vs. Mic Input

    MIC INPUT ●: 4.2MHz, 1500Hz 1-tone MOD. 5-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 268: Ssb Power Measurement

    3. Read “Peak envelope voltage-1: E1” in the said state on the oscilloscope. 5-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 269: Output Power Measurement By 1-Tone Signal

    Continue this measurement until the TX output power becomes saturated. 5-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 270 Since both test tones are set to a specified modulation level, the system facilitates the measurement of TX output power. 5-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 271: T/R Unit Output Power Adjustment And Measurement

    Be sure to restore the setup upon completion of adjustment. TB6 #7-#9 Jumper 5-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 272: Tx Pwr (Freq)

    Selects an output reduction setting level. LOW1 LOW2 5-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 273 Return to Step 3 of this procedure for setting any other mode or frequency band. 5-16 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 274: Tx Pwr (User Ch)

    2. The “TX POWER (FREQ)” window will appear. Appears in case of FS-5075 5-17 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 275 “HIGH,” and then press the [ENTER] knob. 5-18 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 276 The default of TX POWER (USER CH) means power data set with TX POWER (FREQ). 5-19 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 277: Tx Pwr (Tune)

    POWER ADJ” popup window will appear and display the current set power data. 5-20 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 278: Tx Pwr (Sel Call)

    0 ± 10 dBm. 5-21 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 279 [ENTER] knob. SEL CALL power data will return to the default. 5-22 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 280: Atu Output Power

    Fig. 5.3.1 Output Power Measurement circuit-1 5-23 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 281: Connecting Antenna To Atu

    Fig. 5.3.2 Output Power Measurement circuit-2 5-24 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 282: Power Measurement By Calculating Efficiency

    Then, adjust power data so that PA Ic will come to 11.9A. 5-25 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 283: Frequency Measurement And Adjustment

    Fig. 5.4.1 Frequency Measurement Circuit 5-26 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 284: Frequency Measurement Procedure

    “5.6 TONE TEST” on page 5-32. 5-27 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 285 CW output frequency = Set TX frequency 5-28 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 286: Frequency Adjustment

    “within ±10 Hz,” and then press the [ENTER] knob. 5-29 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 287 Fig. 5.4.2 Example of REF OSC Characteristics 5-30 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 288: Dsc Test

    TONE. To make TONE frequency measurement, use the Sub-menu “TX POWER (FREQ).” 5-31 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 289: Tone Test

    This allows for ensuring the setting of tone frequency. 5-32 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 290: Board Adjustment

    FS-2575 PA Board Arrangement Fig. 5.7.1 PA Board Arrangement 5-33 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 291 Fig. 5.7.3 FS-1575 PA Board (05P0868) 5-34 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 292: Pa Board: Pa Transistor Bias Adjustment (Fs-1575, -2575, -5075)

    Fig. 5.7.5 FS-2575: Example of Ammeter Connection 5-35 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 293: Pa Board: Pa Vc Check Meter Reading Adjustment

    VC reading displayed on the “RT SETUP” window of the FS-5075 is “VC1.” 5-36 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 294: Pa Board: Pa Ic Reading Adjustment (Fs-1575, -2575, -5075)

    Fig. 5.7.7 PA IC Reading Adjustment Circuit 5-37 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 295 Fig. 5.7.8 FS-2575: Example of PA IC Reading Characteristics 5-38 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 296: Pa Board: Driv Transistor Q2-Q3 Bias Adjustment (Fs-1575)

    BIAS current: 75 mV/0.5 Ω = 150 mA 5-39 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 297: Drv Board Adjustment (Fs-2575, -5075)

    FS-5075 DRV Board Arrangement Fig. 5.7.10 DRV Board Arrangement 5-40 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 298: Drv Board: Pa Transistor (Q4-Q5) Bias Adjustment (Fs-2575, -5075)

    3. Turn ON the power supply, and then press the PTT on the handset to put the system into a TX state. 5-41 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 299 2. Turn ON the power supply, and then press the PTT on the handset to put the system into a TX state. 5-42 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 300 Fig. 5.7.13 DRV Board: Q4-Q5 BIAS Circuit 5-43 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 301 Fig. 5.7.14 DRV Board: Q2-Q3 BIAS Circuit 5-44 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 302: Drv Board: Pre-Drv Transistor (Q1) Bias Adjustment

    Fig. 5.7.15 DRV Board: Q1 BIAS Circuit 5-45 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 303: Tx Board Adjustment: 05P0856 (Fs-1575, -2575, -5075)

    Fig. 5.7.17 REF OSC Block Diagram 5-46 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 304: Tx Gain Adjustment: R208

    Fig. 5.7.18 Relationship between ALC and TX GAIN 5-47 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 305 8. Set AF GEN output to “1500 Hz/-36 dBm/600 ohms”, and start transmitting (PTT ON). 5-48 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 306 Fig. 5.7.20 TX FIL Board and TX Board 5-49 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 307: Tx Fil Board Adjustment

    Fig. 5.7.22 TX FIL Board (05P0876): FS-1575 5-50 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 308 “R43” ALC variable resistor on the TX FIL board. 5-51 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 309 Fig. 5.7.24 ALC Control Circuit Diagram 5-52 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 310: Pa-If Board Adjustment

    R3: VS Adjustment Fig. 5.7.25 PA-IF Board 5-53 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 311: Coup: 05P0875 (Fs-2575 And Fs-5075)

    Fig. 5.7.27 Example of IA Reading Characteristics 10.0A 5-54 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 312: Reception Testing

    AF signal output power will no longer increase. 5-55 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 313: Measurement Circuits

    [MENU] -> 9.SERVICE -> 3.RT SETUP -> 1.SETUP -> DIVIDER 5-56 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 314: When Passing Signal Through Divider Circuit On Rx Fil Board

    [MENU] -> 9.SERVICE -> 3.RT SETUP -> 1.SETUP -> DIVIDER 5-57 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 315: Reception Specifications

    • SSG output: F+1kHz R.ANT DUP 15dBuV 5-58 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 316: Chapter 6. Maintenance

    COMB board (for FS-5075) and the type of PA-IF board (05P0864 for FS-2575/5075 05P0864A for FS-1575) in combination. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 317: Daily Test

    -> 1.VERSION. For details, refer to information on page 6-23. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 318: Dsc

    1st MIX circuit is not checked. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 319: Wr2

    45MHz Fig. 6.1.3 WR2 Test Circuit Diagram CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 320: Alarm Unit: Ic

    Fig. 6.1.4 ALARM UNIT Test Circuit Diagram CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 321: Tx Self Test

    ✔ ✔ ✔ COUPLER ✔ ✔ ✔ CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 322: Codec

    ON” and “PA ON” signals turn ON the BIAS circuit of the DRV and PA boards. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 323 Fig. 6.1.6 Signals Detected by TX SELF TEST CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 324: Tx Pll

    Fig. 6.1.8 TX PLL CHK Circuit Diagram CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 325 Fig. 6.1.9 TX RF CHK Circuit Diagram 6-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 326: Drv (Fs-2575 And Fs-5075)

    OK when the detected level is not lower than a specified level. 6-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 327: Pa (Fs-1575, Fs-2575, And Fs-5075)

    Fig. 6.1.11 PA CHK Circuit Diagram 6-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 328: Comb (Fs-5075)

    Fig. 6.1.12 COMB Board Block Diagram 6-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 329: Tx Fil (Fs-1575, Fs-2575, And Fs-5075)

    Fig. 6.1.14 COUP CHK Circuit Diagram 6-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 330: Service: Self Check

    Min. 40 (0.032V) 99 (0.08V) 99(0.08V) 6-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 331 Example of FS-1575 SELF CHECK Results 6-16 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 332: Vs [V]

    °C = {(V × 1000) − 424}/6.25 6-17 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 333: Unbalance

    °C = {(V × 1000) − 424}/6.25 6-18 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 334: Filter Vr

    For details, refer to information on page 6-14. 6-19 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 335: Alarm

    If the PLL circuit of any of the TX, RX, WR1, and WR2 boards becomes unlocked, replace the TX board. 6-20 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 336: Service: Restore Factory Settings

    ** FS-2575C: Individually back up the set value. ** 6-21 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 337: Clear Procedure

    For details, refer to information on page 4-4. 6-22 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 338: Service: Test

    Displays program version. Displays board version. 6-23 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 339 Note) Displays updated version and date. Example: 01.03.20110805 6-24 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 340 BOOT program to be updated is the starter program. Note) 0550247-xx.xx 6-25 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 341 SH-2A CPU to the 78K CPU. The following window shows a program in the process of updating. 6-26 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 342: Verifying Board Version

    Fig. 6.5.1 Version Verification Circuit Diagram for FS-5075 6-27 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 343: Verification Of Model: Board Inst Signal

    This signal is not in use. 6-28 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 344 Fig. 6.5.3 INST Signal of COMB / PA-IF Board 6-29 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 345 The output port is #1 to #2 (TD A/B) of TB6 on the T-IF board. 6-30 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 346: T-Cpu Pcb Test

    For details, refer to information on page 6-27. 6-31 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 347: C-Cpu Pcb Test

    C-CPU board. The column displays the results of Read/Write tests, respectively. 6-32 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 348: Test]: Nbdp

    Pressing the [ENTER] knob will switch the display to the (2/4) window and automatically conduct LED tests. 6-33 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 349: Back Led

    • BUSY ERROR ! : Printer line is OFF. 6-34 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 350: Encoder Knob

    Pressing the KEY will turn the key display in question from black to blue. 6-35 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 351: Lcd Test

    Then, press the [MENU] key twice to exit from the C-CPU test mode. 6-36 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 352: Ta Test

    Fig. 6.5.4 CONTACT SIG and LOOP BACK Signal Circuit Diagram 6-37 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 353: Ac Fail

    To stop printing, click on “STOP.” 6-38 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 354: Distress Scan

    • Between #4 (IC TD-B) and #6 (IC RD-B) of TB7 6-39 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 355: Remote

    “0” to “17.” 6-40 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 356: Panel Key Led

    Every time the [3] key is pressed, the LCD window changes to “White” -> “Black” -> “Previous window.” 6-41 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 357: Maintenance Log

    For details, refer to information on page 4-80. 6-42 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 358: Error Log

    • SHIP’S MAIN FAILURE • VC ERROR 6-43 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 359: Software Update Log

    6-44 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 360: Power On Log

    T-CPU board whether they have any error in operation. When an error is detected, the system will restart. 6-45 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 361: Information Log

    • CLEAR ALL (Set “S1” on the T-IF board to “ON,” and then enter the password.) 6-46 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 362: Erasing Fs-2575C Software

    NIGHT MODE, DAY MODE LED & LCD Day mode: Max. setting mode 6-47 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 363 “INITIALIZING…” window. This state continues for a while. 6-48 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 364 “SOFTWARE ERASE,” this will not be recorded in the software update log. 6-49 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 365: Led Check

    3. FPGA LED CR14 CR9, 11 6-50 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 366: Mot Board (05P0860)

    Turns ON when CPLD is in operation (when power supply turns ON). 6-51 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 367: Leds For Fs-Xx75C Unit

    FPGA LED Normally turns OFF. 6-52 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 368: Leds For Nbdp Terminal

    ・While the application program is running: Blinks slow. 6-53 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 369: Checking Antenna Coupler

    CR10 (RUN) [TUNE], [CHECK] AT-5075 AT-1575 6-54 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 370: Checking For Matching Circuit Relays

    (in 100-msec period). 6-55 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 371: Checking Antenna Coupler

    Checking cables Checking leads Fixing components 6-56 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 372: Ensuring Connection Of Coaxial Cable

    The copper band should be as short as possible. 6-57 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 373: Ensuring Antenna Connection

    Antenna coupler or RT breakdown. 6-58 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 374: Troubleshooting For Tune Ng

    8) change the length of the antenna lead-in wire. 6-59 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 375: Replacement Of Boards

    Antenna Coupler unit 05P0875 AT-5075 COUP 05P0883 AT-1575 6-60 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 376: Precautions For Replacing Board

    Flat Cable T-CPU Board Flat Cable 6-61 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 377 Not displaying VC error popup message 6-62 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 378: Replacing Mot Board

    Board Mounting Guide Pin Guide Hole for Board Connector 6-63 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 379: Replacing C-Cpu Board

    80deg. Flat Cable 6-64 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 380: Replacing Speaker

    6-65 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 381: Applying A Coating Of Silicones Compound

    FS-2575T- Heat Sink Side FS-1575T- Heat Sink Side 6-66 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 382 FS-5075: 05P0867A FS-2575: 05P0867B FS-1575: 05P0868 6-67 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 383 4) COMB board (FS-5075: 05P0869) 5) FET board (FS-5075: 05P0872) 6-68 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 384: Actions To Be Taken After Replacing Boards

    TX FIL board. For the adjustment procedure, refer to information on page 5-50. 6-69 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 385: Drv Board: 05P0866A, 05P0866B (Fs-5075, -2575)

    9. DUP-FIL board: 05P0863 (FS-5075) No setting is required. 6-70 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 386: Rx Fil Board: 05P0862A, 05P0862B (Fs-5075, -2575/-1575)

    2) Set the “S2” DIP switch all to “OFF.” DIP SW: S2 (ALL OFF) 6-71 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 387: T-If Board: 05P0861, 05P0861A (Fs-5075/-2575, -1575)

    2) Set the “S2” DIP switch all to “OFF.” DIP SW: S2 (ALL OFF) 6-72 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 388: Panel Board: 05P0844

    For details, refer to information on page 4-93. AT-5075 AT-1575 6-73 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 389: Level Check

    “WR1, 2 PLL UNLOCK” will be outputted. 6-74 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 390: Drv Board: 05P0866A, B (Fs-5075, -2575)

    Q4, 5: SD1407 Drain: 15.0 VDC 6-75 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 391 Fig. 6.11.2 FS-5075 DRV Board - Example of CHK DA, VR DA vs. Power Characteristics 6-76 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 392 Fig. 6.11.4 Power Check Using DRV Board Alone 6-77 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 393: Pa Board: 05P0867A, B (Fs-2575, -5075)

    Fig. 6.11.5 FS-2575 and -5075 - PA Board Block Diagram 6-78 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 394 Fig. 6.11.7 FS-2575 PA Board - Example of CHK PA, VR PA vs. Power Characteristics 6-79 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 395 Fig. 6.11.8 FS-2575 and -5075 - Power Check Using DRV Board plus PA Board Alone 6-80 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 396: Pa Board: 05P0868 (Fs-1575)

    Fig. 6.11.9 FS-1575 - PA Board Block Diagram 6-81 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 397 Fig. 6.11.11 FS-1575 - Power Check Using PA Board Alone 6-82 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 398: Comb Board: 05P0869 (Fs-5075)

    Fig. 6.11.12 FS-5075 - COMB Board Block Diagram 6-83 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 399: Tx Fil Board: (Fs-1575, -2575, -5075)

    Fig. 6.11.14 FS-5075 TX FIL Board - Example of CHK IN VR, ALC vs. Power Characteristics 6-84 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 400 Fig. 6.11.16 FS-1575 TX FIL Board - Example of CHK IN VR, ALC vs. Power Characteristics 6-85 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 401: Chapter 7. Block Description

    RX antenna or shared use of T/R antenna CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 402: Configuration Of Fs-5075T

    Fig. 7.1.2 Configuration of FS-5075T Transceiver Unit CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 403: Configuration Of Fs-2575T

    Fig. 7.1.3 Configuration of FS-2575T Transceiver Unit CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 404: Configuration Of Fs-1575T

    Fig. 7.1.4 Configuration of FS-1575T Transceiver Unit CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 405: Configuration Of Fs-2575C

    Fig. 7.1.5 Configuration of FS-2575C Control Unit CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 406: Major Functions Of Boards

    FS-1575 05P0870A/B, but different in power capacity. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 407 CODEC, ADC, FPGA, and DSP. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 408: Control Unit: Fs-2575C

    Provides the same function as above. 05P0883 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 409: Transmission Circuit

    Lo frequency in the 2nd Mixer circuit. Furthermore, this TX board controls TX output power. The TX board outputs power to the PA board in case of the FS-1575 system and to the DRV board in case of FS-2575 and FS-5075 systems.
  • Page 410: Khz Tx If Signal

    Fig. 7.2.2 SSB TX IF Input vs. Board Output Power Level 7-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 411: Mhz Vctcxo

    • USB: +1.5 kHz ・H3E, CW, TLX: 0 kHz 7-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 412: Tx Output Power Control Circuit

    4. TX output power control circuit 7-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 413 7.2 Transmission Circuit 7-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 414 7.2 Transmission Circuit 7-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 415 Fig. 7.2.5 Example of FS-2575 Power Control Input vs. Output 7-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 416 Reference above. 7-16 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 417 And for the power reduction control. 7-17 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 418: Tx Board Self-Test Detection Circuit

    [MENU] -> 9.SERVICE -> 5.TEST -> 1.VERSION. 7-18 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 419: Drv Board

    Fig. 7.2.7 DRV Board Block Diagram 7-19 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 420 Fig. 7.2.8 Example of DRV Board Frequency Characteristics 7-20 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 421: Protection Circuit

    150 mA TP1 - TP2: 75 mV 7-21 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 422: Pa Board-1

    Fig. 7.2.9 FS-2575/FS-5075 PA Board Block Diagram 7-22 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 423 Fig. 7.2.10 Example of PA Board Frequency Characteristics Frequency Characteristics 7-23 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 424: Bias Adjustment

    DRV boards remains at the threshold for a period of one minute or longer. 7-24 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 425 Fig. 7.2.12 FS-1575 PA Board Block Diagram 7-25 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 426: Protection Circuit

    77°C or above 84°C or above 7-26 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 427: Imd Improvement

    PA IC. 7-27 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 428: Comb Board (05P0869): Fs-5075T

    Fig. 7.2.13 COMB Board Block Diagram 7-28 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 429: Tx Fil Board

    Fig. 7.2.14 TX FIL Board Block Diagram 7-29 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 430: Lpf Circuit

    8M: PA OUT 8M: TX FILOUT 7-30 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 431: K17: 50-Ohm Bk Relay Circuit

    0dB line 4.5-6.6M LPF 3.2-4.5M LPF 7-31 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 432 0dB line 14-20M LPF 20-27M LPF 7-32 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 433: Pa-If Board

    Fig. 7.2.15 PA-IF Board (05P0864) Block Diagram 7-33 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 434 UN_BAL PA of the COMB board 7-34 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 435: Vs Detection

    05P0864 FS-5075 Not mounted Mounted 05P0864 7-35 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 436: Protect Signal (Fs-2575 And Fs-5075)

    Fig. 7.2.17 PROTECT Signal Circuit Diagram 7-36 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 437: Receiver Circuit

    Fig. 7.3.1 RX FIL Board Block Diagram 7-37 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 438: Receiving Filters Of Rx Fil Board

    BAND-1: 100 to 1449.9 kHz BAND-3: 5000 to 7999.9 kHz 7-38 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 439: Pre-Selector

    PRESEL: 2200 to 2249.9 kHz PRESEL: 4200 to 4549.9 kHz 7-39 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 440: Rx Div

    Output: DIV OUT1 Example of DIV Amplifier Characteristics 7-40 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 441 Fig. 7.3.3 Example of Receiving Antenna Divider Installation Pattern 7-41 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 442: Dup Fil Board (05P0836): Fs-5075

    Fig. 7.3.4 Example of Installation Pattern for Duplex Specification 7-42 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 443 DUP-FIL Characteristics Tx B.W RX B.W 7-43 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 444 25M DUP FIL/Span 4MHz 22M DUP FIL/Span 4MHz 7-44 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 445: Rx Board (05P0842): Common Board

    54 MHz 2nd IF 36 kHz 7-45 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 446: Khz If Rx Signal

    Fig. 7.3.7 Example of 36-kHz RX IF Signal Input vs. Output Characteristics 7-46 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 447: If Agc

    However, even if the RF ATT automatically turns ON, “ATT” will not appear on the RT window. 7-47 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 448: Pll Synthesizer Circuit

    [MENU] -> 9.SERVICE -> 5.TEST -> 1.VERSION. 7-48 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 449 Fig. 7.3.11 AF OUTPUT Characteristics Fig. 7.3.12 S Meter Characteristics 7-49 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 450: Wr Board

    Fig. 7.4.1 WR Board Block Diagram 7-50 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 451: Differences Between Wr1 And Wr2 Boards

    RF FIL 2 18-MHz LPF 30-MHz LPF 7-51 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 452: If Wr

    50 to 55dBm in reverse gain mode. This is the level that TP-1 voltage falls from 3.5V. 7-52 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 453: Pll Synthesizer Circuit

    “J3” of the WR boards to the “active” side, and then supply 12V power to the FAX-5 pre-amplifier. 7-53 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 454: Interface

    Fig. 7.5.1 T-IF Board Block Diagram 7-54 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 455: Mot Board (05P0860) For Shared Use

    Fig. 7.5.2 MOT Board Block Diagram 7-55 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 456 Fig. 7.6.1 T-CPU Board (05P0859) Block Diagram 7-56 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 457: T-Cpu

    Fig. 7.6.3 Overview of Transmission Processing Circuit within DSP Transmitter 7-57 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 458 Fig. 7.6.5 Overview of Received DSC/NBDP Signal Processing within DSP 7-58 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 459: Overview Of Transmitted Voice Signal Route

    Fig. 7.6.7 Overview Diagram of Received Voice Signal Channel 7-59 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 460: Transmitted Nbdp Signal Route

    Fig. 7.6.9 Overview Diagram of NBDP RX IF Signal Channel 7-60 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 461: Transmitted Dsc Signal Route

    Fig. 7.6.11 Overview Diagram of WR1 IF Signal Channel 7-61 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 462: Received Dsc (Wr2) Signal Route

    Fig. 7.6.12 Overview Diagram of WR2 Signal Channel 7-62 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 463: Voice Signal Processing

    NB set to ON in SSB Mode 7-63 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 464: Nr1 And Nr2 (Noise Reduction)

    SSB mode in SSB mode 7-64 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 465: Memory

    78K CPU when turning ON the power supply. 7-65 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 466: High-Speed Serial Communication

    • Configuration of command packet Model name+Source+Destination+Command+Voice data (80 bytes) 7-66 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 467: Power Supply

    REG board has a built-in overcurrent (19A) protection circuit. 7-67 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 468: Power Supply Circuit Diagram

    Fig. 7.7.1 FS-5075 Power Supply Circuit Block Diagram 7-68 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 469: Fs-2575 Power Supply Circuit Diagram

    Fig. 7.7.3 FS-1575 Power Supply Circuit Block Diagram 7-69 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 470: Control Unit: Fs-2575C

    J110 Fig. 7.8.1 FS-2575C Block Diagram 7-70 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 471: C-Cpu Board: 05P0852

    For details, refer to information on page 6-47. 7-71 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 472: Antenna Coupler

    Fig. 7.9.1 COUP Board (05P0875) Block Diagram 7-72 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 473: Control Signal Timing

    FS-2575C unit. Not used for the matching procedure. 7-73 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 474 7-74 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 475: Overview Of Matching Procedure

    The voltage is given as: 7-75 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 476: Self-Test

    4) Upon completion of the self-test, the system will return to the original state. 7-76 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 477: Monitoring Matching Status

    Ci: 0 L: 15 Co: 10 7-77 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 478 Ci: 1 L: 8 Co: 20 7-78 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 479 VSWR= 1.747(365 99) IA= 17 Ci: 0 L:25 Co: 30 7-79 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 480 Ci: 9 L: 9 Co: 30 7-80 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 481 Ci: 0 L: 19 Co: 40 set_memory tune_ok time=8208[ms] turn=145 7-81 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 482 Ci: 53 L: 291 Co: 0 7-82 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 483 Ci: 91 L: 280 Co: 0 7-83 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 484 Ci: 76 L: 288 Co: 0 7-84 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 485 Ci: 0 L: 747 Co: 0 7-85 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 486 Ci: 62 L: 612 Co: 4 7-86 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 487 ADC VF=0 VR=0 HOT=539 IA=0 turn:5554 > thresh:1644*2 trace_mode on 7-87 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 488 L: 679 [SKIP]) IA= 17 Ci: 0 L: 10 Co: 20 7-88 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 489 Ci: 46 L: 420 Co: 8 CHARENGE_CO:30 7-89 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 490 Ci: 62 L: 375 Co: 8 7-90 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 491 Ci: 0 L: 688 Co: 4 set_memory tune_ok time=15824[ms] turn=302 7-91 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 492: Calculation Of Matching Circuit

    Fig. 7.9.5 Table of Gamma-matching Constants 7-92 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 493 Fig. 7.9.7 Table of Loading Coil Constants 7-93 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 494: Pi-Matching

    Fig. 7.9.9 Pi-matching Measurement Constant for 50-ohm Loads 7-94 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 495: Nbdp Terminal

    RESET Fig. 7.10.1 TERMCPU Block Diagram 7-95 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 496 Incompatible PWR C 16P0214A 16P0214A Compatible 7-96 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 497: Termpwr (16P0287A)

    (Protection circuit activated at 14.2A. Overcurrent detected with R33) 7-97 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 498 • Keyboard connection (U7): Connect the keyboard (PS/2) • FDD (U7): 2HD compatible 7-98 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 499: Termcpu (16P0209A)

    • Timer OP • System data 7-99 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 500: Pwr (16P0211A)

    Fig. 7.10.5 PWR Board Block Diagram 7-100 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 501: Chapter 8. Updating Program

    The program version and date (e.g. 01.00 20110902) of the C-CPU program are displayed. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 502: List Of Program Files

    (2) CPU: Nios2 Fig. 8.1.1 CPU and Memory Configuration CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 503: Verifying Program Version

    To print out daily test results, press the [4] key. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 504 For details, refer to information on page 6-23. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 505: Program Updating Procedure

    It takes approximately 8 minutes to update all programs aforementioned. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 506 PC according to the set network address. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 507 ON the power of this unit as well. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 508 [CANCEL] key to clear the message. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 509 Then, press the [ENTER] key on the PC. The Command Prompt window will disappear. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 510 APP, BOOT, and FPGA in the [FS-2575C] column of this menu. 8-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 511 RT window. 8-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 512: When Program Version Is Different Between T-Cpu And C-Cpu

    RT window. 8-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 513: Nbdp Terminal Updating Program

    Displays the results of communication tests with the printer. 8-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 514: Updating Program

    7. Turn OFF the power once to reset the system. 8-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 515 9. Turn OFF the power once to reset the system. 8-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 516: Updating Program

    USB Test USB Test alphanumeric characters. 8-16 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 517: Updating Program

    (female) (male) 9 pin D-sub (male) 8-17 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 518 6. Upon completion of the program update, the NBDP window will automatically appear. 8-18 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 519 Verifying Check-SUM. Processing xx% < 0000000000__________________________________________> 8-19 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 520 Program update is CANCELED. Please remove SD-Card reboot. 8-20 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 521: Additional Information: Updating Program Via Serial Port

    UPPG.exe LDALL576.BIN FSXX75.BIN 0 0 0 1 1 COM port number 8-21 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 522 The updating procedures for the T-CPU, C-CPU and 78K CPU are the same way. 8-22 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 523 Check the program version number. 8-23 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 524: Chapter 9. Q&A

    You can also register MMSI from the Parameter Browser. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 525: Q9. How To Enter Service Menu

    MMSI or entry of positional data. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 526: Q18. Are Alarms Outputted With The Output Contact Set To "N.c" Or "N.o

    [MENU] -> 7.AUDIO -> 5.SIDE TONE and 6.SIDE TONE LV CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 527: Q23. Is It Possible To Connect A Selcall (Selective Calling) System

    A29. These figures deviate from the threshold for self-checks. There is a problem with the relevant circuit. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 528: Q30. Which Of The Gnss And Manual Modes Is Given Priority To Enter Data

    “TR1.” Executing the TUNE will display the matching process. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 529: Q38. I Would Like To Know Precautions

    25 to 30A (40A) FS-1575(150W) PR-300 (20A) CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 530: Q40. Tx Output Power Has Dropped Just In 8M

    ATU failure. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 531: Q44. Is Transmission Enabled Even When Tune Ng Occurs

    [MENU] -> 7.AUDIO -> 2.OFF HOOK -> “SP ON.” CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 532: Q51. Is There Any Method For Stopping Distress Scan Mode

    Distress ACK. Upon receipt of the Distress ACK, the CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 533: Q57. What Happens If I Accidentally Transmitted A Distress Alert

    RX-FIL board. 9-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 534: Q63. No Norwegian Characters And " Q64. I Implemented The Screen Print Menu Of The

    9-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 535: Q68. I Would Like To Know The Procedure For Making Dsc Test Calls

    Coast radio station. 9-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 536 9-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 537: Q70. I Would Like To Know Dsc Frequencies

    TX and RX. *1: Not available 9-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 538: Appendix 1. Parameter Browser

    Set values will be uploaded onto the FS-xx75 system. AP1-1 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 539: Ap1.1 Installation

    When you reinstall a General Menu Manager program, delete this program first. AP1-2 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 540: Ap1.2 Booting General Menu Manager

    “P-BROWSER” will be set back to “OFF” when turning ON the power again. AP1-3 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 541 • TCP Port : Set to 10999 AP1-4 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 542 Note) The numbers such as “50800000” is the ID number of parameters internally processed. AP1-5 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 543 [RELOAD] key. AP1-6 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 544: Ap1.3 Display

    Displays the setting range of a parameter selected. AP1-7 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 545: Menu Tree Display Window

    Menu Tree window will be downloaded in a batch. AP1-8 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 546: Main Window

    FS-xx75 system and, subsequently, update the contents of the window. AP1-9 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 547: Parameter Information

    Main window. AP1-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 548: Ap1.3.2 Menu Tree

    SYSTEM -> 9.NETWORK -> IP Cont’d ADDRESS. AP1-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 549 FS-xx75 system in an XML format. AP1-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 550: Ap1.4 Operation

    [SET] key. AP1-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 551: Ap1.4.1 Reload

    PC. XML File General Menu Manager AP1-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 552: Ap1.4.3 Upload

    [SET] key for the “Batch Download/Upload” key in NORMAL MODE AP1-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 553: Ap1.4.4 Local Mode

    “Save As”. AP1-16 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 554: Ap1.4.5 Uploading Xml File To Fs-Xx75

    [SET] key for the “Batch Download/Upload” key in NORMAL MODE AP1-17 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 555: Ap1.5 Other Operations

    The Preview window will appear. Click on the Print key to print out the menu. AP1-18 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 556: Ap1.5.2 Saving All Parameters In Csv File Format

    COMB TX_FIL COUPLER =====USER CH================================= =====00-99=================================== AP1-19 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 557: Ap1.5.3 Registering Name

    DAILY TEST RESULT TX SELF TEST RESULT AP1-20 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 558: Ap1.5.4 Making Mmsi Setting

    General Menu Manager: SERVICE MENU -> MMSI SETUP -> MMSI AP1-21 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 559 5. Reboot the power supply of the FS-xx75 again to ensure that the MMSI setting has been properly made. AP1-22 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 560: Ap1.5.5 Executing Clear All

    STATUS Display [START] Key AP1-23 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 561: Ap1.5.6 Conducting Daily Test, Self-Test, And Self-Check

    DAILY TEST/SELF TEST Results window. AP1-24 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 562: Ap1.5.7 Making Auto Reload Setting

    “Version Information.” AP1-25 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 563: Appendix 2. Message List

    [CANCEL] key is pressed. AP2-1 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 564 The condition for stopping this alarm sound is that the [CANCEL] key is pressed. AP2-2 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 565 The condition for stopping this alarm sound is that the [CANCEL] key is pressed. AP2-3 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 566 [CANCEL] key is pressed. AP2-4 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 567: Ap2.2 Messages Related To Setting Errors

    [CANCEL] key is pressed. AP2-5 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 568: Ap2.3 Messages Related To Hardware Errors

    The condition for stopping this alarm sound is that the [CANCEL] key is pressed. AP2-6 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 569 Ring-back tone is that the [CANCEL] key is pressed. AP2-7 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 570: Ap2.4 Status Messages

    AP2-8 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 571 User Option is set to any menu, and then the [ENTER] knob is pressed. AP2-9 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 572 [ENTER] knob is pressed. AP2-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 573 The condition for deleting this message is that the [ENTER] knob is pressed. AP2-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 574 [CANCEL] key is pressed. AP2-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 575 [CANCEL] key is pressed. AP2-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 576 [ENTER] knob or [CANCEL] key is pressed with the cursor put on any Option. AP2-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 577 [ENTER] knob or [CANCEL] key is pressed with the cursor put on any Option. AP2-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 578: Appendix 3. Specifications

    AGC, Noise Blanker, Voice-activated squelch, Noise reduction AP3-1 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 579: Dsc/Watch Keeping Receiver

    4.5 Alarm volume 80 to 85 dB(A) AP3-2 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 580: Terminal Unit (Option)

    100/110/120/200/220/240 VAC, 1 phase, 50/60 Hz AP3-3 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 581: Environmental Condition

    N2.5 10.2 Antenna coupler N9.5 (white) AP3-4 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 582: Appendix 4. Test Data

    1. FS-1575 2. FS-2575 3. FS-5075 AP4-1 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 583 5. 1TONE・・1500Hz 2 TONE・・700Hz/1700Hz : N/A AP4-2 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 584 23.5 206.8 31.1 65.0 1TONE (ITU401) AP4-3 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 585 5. 1TONE・・1500Hz 2 TONE・・700Hz/1700Hz : N/A AP4-4 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 586 15.5 41.0 246.0 40.6 1TONE (ITU401) AP4-5 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 587 5. 1TONE・・1500Hz 2 TONE・・700Hz/1700Hz : N/A AP4-6 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 588 22.5 42.1 383.1 28.7 1TONE (ITU401) AP4-7 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 596: Fs-2575C

    SCHEMATIC DIAGRAM IF-8500 C6503 –K10 S-13 (IF-8500) S0-1 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
  • Page 597 2.6m WHIP ホイップアンテナ 04S4176 WHIP ANTENNA プリアンプ PREAMP 2.6m WHIP M-P-7 FAX-5 04S4176 RG-10/UY 送受信部 FS-2575T/5075T ARD-1/ AJB1-1A プリアンプ TRANSCEIVER UNIT WR1_ANT M-P-3 FMA-1 M-P-3 M-P-3 PREAMP 3D-2V,MAX.50m IV-2sq. ハンドセット HANDSET DSUB15-5P-L**M, FAX-5 TRANSCEIVER OR RG-10/UY(M-P-7) HANDSET 5/10/20/30/40/50m,φ7.8 TB5 CONTROLLER1 IV-2sq.
  • Page 598 AC IN 1φ,50/60Hz IV-2sq. AC-DC電源ユニット IV-8sq. *1 *3 AC/DC POWER DPYC-6 24VDC SUPPLY UNIT PR-300 注記 *1)造船所手配。 *2)オプション。 *3)長さに応じて芯線太さを変更する。 DRAWN TITLE FS-1575 T.YAMASAKI *4)内部スイッチ設定が必要。 8/Dec/2011 CHECKED 名称 NOTE SSB送受信機 H.MAKI 8/Dec/2011 *1: SHIPYARD SUPPLY. APPROVED Y.NISHIYAMA 相互結線図 8/Dec/2011 *2: OPTION. SCALE...
  • Page 605 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.