Page 1
SERVICE MANUAL Ku-BAND VSAT SSB RADIOTELEPHONE FV-100 FS-1575/2575/5075 MODEL CONFIDENTIAL for Internal Use Only This document is only for a service staff of FURUNO products. Any unauthorized reproduction of any of its content is prohibited. www.furuno.co.jp...
Page 2
Nishinomiya, 662-8580, JAPAN A : JUN 2012 Printed in Japan All rights reserved. B : NOV . 26, 2012 Pub. No. SME-56770-B *00017687610* *00017687610* (NAYO ) FS-1575/2575/5075 *00017687610* *00017687610* * 0 0 0 1 7 6 8 7 6 1 0 *...
1.3.4 Reception of DSC Message ································································ 1-16 1.3.5 Audio Alarms ······················································································· 1-17 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 4
3) SW board (16P0212) ·············································································· 2-64 2.7.2 IB-585 ···································································································· 2-65 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 5
4.3.5 [5. DATE/TIME] ····················································································· 4-18 4.3.6 [6. TIME OUT] ······················································································· 4-19 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 6
5. DSC/DSE SENTENCE (ON, OFF) ························································· 4-59 6. LAST DISTRESS LOG ··········································································· 4-60 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 7
4.14.4 Making Setting of “F6: System” Menu ··············································· 4-101 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 8
2. Output power measurement by 1-tone signal ········································· 5-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 9
5.7.6 COUP: 05P0875 (FS-2575 and FS-5075) ············································· 5-54 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 10
13. FILTER VR ····························································································· 6-19 14. FILTER ALC···························································································· 6-19 viii CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 11
11. ALARM UNIT ·························································································· 6-39 12. REMOTE ································································································ 6-40 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 12
6.9.3 Troubleshooting for TUNE NG ······························································ 6-59 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 13
6. TX FIL board: (FS-1575, -2575, -5075) ···················································· 6-84 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 14
3. PROTECT signal (FS-2575 and FS-5075) ··············································· 7-36 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 15
3. SW REG (05P0873): FS-2575 and FS-5075 ········································· 7-67 xiii CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 16
1. Verifying IB-583 program version ····························································· 8-13 2. IB-583 updating program ·········································································· 8-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 17
Q30. Which of the GNSS and Manual modes is given priority to enter data? ······ 9-5 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 18
Q60. Are front and rear handsets the same in the MIC gain? ···························· 9-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 19
AP1.5.8 Verifying Version of General Menu Manager ······························· AP1-25 xvii CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 20
IB-585 ················································································································· E-8 Contents of Drawings ······································································ S0-1 xviii CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Furthermore, describe antenna type, length, and lead-in length without fail. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
The password “XXXXXX” is the same as that for the FS-xx70 series. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
C-CPU, 40 seconds after turning ON the power. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
- Select [MENU] -> 9.SERVICE -> 3.RT SETUP -> 1.SETUP -> DIVIDER -> “OFF.” CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
If no problems, it is advisable to reduce power by 10% to 20%. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
3.RT SETUP -> 4.TX PWR (FREQ) -> “DSC.” CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Make settings of J4 (ANT BK) 05P0883 COUP and J5 (ANT GND). CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
If T/R antenna is of the self-supporting type, are elements securely 1.21 mounted? CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 29
Slave Delay? IB-583 -> 8msec, IB-585 -> 12msec CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 30
16M : 18M : 22M : 25M : CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Date / Time Result Station Voice NBDP CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
RX-only antenna or shared use of T/R antenna CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 1.1.1 FS-2575 and -5075 System Configuration Diagram CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
PR-300 Fig. 1.1.2 FS-1575 System Configuration Diagram CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 35
Used to give priority to SPEAKER 4Ω/5W external speaker (φ3.5 jack) CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[MENU] -> 9. SERVICE -> 3. RT SETUP -> 1. SETUP -> Set DIVIDER to “ON” CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Option Fig. 1.2.1 Example of Antenna Wiring CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Cable length (m) Fig. 1.2.2 Voltage Drops in Cables:5% CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Turns ON (in Green) when 24 V power is supplied to FS-xx75T. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
On the DSC window and the MENU window, appears when the emission type is set to “FAX”. 1-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
User option Tab: Procedure being initiated 1-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 43
UNABLE ACK creation window. 1-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
- ROUTINE SCAN Stop : [SCAN ] 1-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
: Transmits at a specified frequency out of 2M to 16M band five times. 1-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
3.5 - 4.5 min. 3.5 - 4.5 min. 1-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
If WR2 is not incorporated, DSC general messages are received on the “RT.” 1-16 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
2200 Hz and 0 Hz (500 ms) 1-17 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[PRINTER] [TRANSCEIVER] Fig. 2.1.2 Rear panel view CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 50
Fig. 2.1.5 Rear panel, C-CPU board removed CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 51
Fig. 2.1.7 Front panel, PANEL board removed SP: S50U33-K0014A (10W/4Ω) Fig. 2.1.8 Speaker CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 52
U4: 256Mbit SDRAM Fig. 2.1.10 C-CPU board: 05P0852 (B-side) CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 53
Fig. 2.1.12 C-IF board: 05P0853 (B-side) Fig. 2.1.13 PANEL board: 05P0844 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
LAN port Fig. 2.2.2 FS-1575T, bottom view CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 55
Fig. 2.2.4 FS- 1 575T, door opened CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 56
J8: EXT ALM setting Fig. 2.2.5 FS-1575T, shield cover removed CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 57
PA-IF: 05P0864A Fig. 2.2.6 FS-1575T, heat sink side CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 58
Fig. 2.2.7 FS- 1 575T, mounting board (A-side) 2-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 59
Fig. 2.2.8 FS-1575T, mounting board (B-side) 2-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[REMOTE] Fig. 2.3.2 FS-1575T, bottom view 2-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 61
05P0861 Fig. 2.3.4 FS-2575T, door opened 2-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 62
2.3 Transceiver Unit: FS-2575T Fig. 2.3.5 FS-2575T, PCB LAYOUT 2-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 63
Fig. 2.3.6 FS-2575T, shield cover removed 2-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 64
Fig. 2.3.7 FS-2575T, heat sink side 2-16 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 65
Fig. 2.3.8 FS-2575T, mounting board (A-side) 2-17 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 66
Fig. 2.3.9 FS-2575T, mounting board (B-side) 2-18 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[REMOTE] Fig. 2.4.2 FS-5075T, bottom view 2-19 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 68
PCB LAYOUT Fig. 2.4.4 FS-5075T, door opened 2-20 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 69
2.4 Transceiver Unit FS-5075T Fig. 2.4.5 FS-5075T, PCB LAYOUT 2-21 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 70
Fig. 2.4.6 FS-5075T, shield cover removed 2-22 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 71
Fig. 2.4.7 FS-5075T, heat sink side 2-23 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 72
Fig. 2.4.8 FS-5075T, DRV board removed 2-24 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 73
Fig. 2.4.10 FS-5075T, RX-FIL and DUP FIL board 2-25 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.2 TX-FIL board (05P0876) B-side 2-26 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.4 TX-FIL board (05P0870B) B-side 2-27 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
05P0870A: J2, JP1 not mounted 05P0870B: J1, not mounted 2-28 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.8 COMB board (05P0869) B-side 2-29 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.10 PA board (05P0868) B-side 2-30 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.12 PA board (05P0867B) B-side 2-31 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.14 PA board (05P0867A) B-side 2-32 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.16 DRV board (05P0866B) B-side 2-33 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.18 DRV board (05P0866A) B-side 2-34 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.20 TX board (05P0856) B-side 2-35 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.22 PA-IF board (05P0864) B-side 2-36 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.24 PA-IF board (05P0864A) B-side 2-37 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.26 RX-FIL board (05P0862B) B-side 2-38 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.28 RX-FIL board (05P0862A) B-side 2-39 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.30 DUP-FIL board (05P0863) B-side 2-40 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.32 RX board (05P0842) B-side 2-41 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.34 WR1 board (05P0847A) B-side 2-42 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.36 WR2 board (05P0847B) B-side 2-43 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.38 T-IF board (05P0861A) B-side 2-44 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.40 MOT board (05P0860) B-side 2-45 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.42 T-CPU board (05P0859) B-side 2-46 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.44 SW-REG board (05P0873) B-side 2-47 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.46 PWR board (05P0874) B-side 2-48 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.48 P-SW board (05P0871) B-side 2-49 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.5.50 FET board (05P0872) B-side 2-50 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.6.1 AT-5075 2.5mm: 8kV Fig. 2.6.2 Arrester 2-51 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 100
Fig. 2.6.4 COUP board (05P0875 ) B-side 2-52 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 101
Fig. 2.6.5 COUP board terminal area 2-53 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 102
Fig. 2.6.7 ATU GND, Drain tube 2-54 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.6.8 AT-1575-AES Weight: 8.8kg Fig. 2.6.9 AT-1575-SUS 2-55 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 104
Fig. 2.6.10 AT-1575-AES 2mm: 6kV Fig. 2.6.11 Arrester 2-56 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 105
Fig. 2.6.12 AT-1575-SUS 2mm: 6kV Fig. 2.6.13 Arrester 2-57 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 106
Jumper: J4 #2 – J4 #4 Fig. 2.6.14 COUP board (05P0883) 2-58 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Power SW Fig. 2.7.1 IB-583 Overview 2-59 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 108
Fig. 2.7.3 FDD connector - 2 2-60 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 109
Fig. 2.7.5 J6 flat cable - 3 2-61 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 110
LCD unit (LCD:NL6448BC33-46) Fig. 2.7.6 Panel 2-62 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 2.7.7 TERM CPU board (16P0209A) 2-63 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
(Distress button for FELCOM15) Fig. 2.7.9 SW board (16P0212) 2-64 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 113
Key board Fig. 2.7.10 IB-585 Overview 2-65 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 114
LCD panel Fig. 2.7.12 boards removed 2-66 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 115
Fig. 2.7.14 Mounting chassis of LCD panel Fig. 2.7.15 LCD panel 2-67 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 116
Fig. 2.7.17 TERM CPU board ( 16P0283A ) B-side 2-68 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 117
Fig. 2.7.20 SD USB board ( 16P0289 ) 2-69 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
ON/OFF hook detector) Fig. 2.8.2 Handset Hanger 2-70 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
VR1: over current VR2: output power 2-71 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 120
100V: 10A Output:20A 220V: 5A 2-72 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 121
Input power Fuse: 2A Output Voltage ADJ. 2-73 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
The service mode will be canceled three minutes after exiting from the service menu. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
CH: 1-29/00-99 TX FREQ: xxxxx.x RX FREQ: xxxxx.x CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 124
5. DATE/TIME DATE dd/mm/yyyy TIME xx:xx UTC CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 125
8. EXTERNAL 2. SAFETY ALARM 3. ROUTINE CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 126
DSC FREQ: 2 – 16M DIS/SAF FREQ FAIL NAME: CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 127
- MF: 6. DISTRESS SCAN -> Deleted ON/OFF ON/OFF CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 128
8. ALARM Displays alarm currently in progress. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 129
(200Hz) TX TUNE COUPLER RCVD THROUGH DIFF CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 130
1100/1700Hz 1785Hz 1785Hz 700/1700Hz <LOAD DEFAULT> YES/NO CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 131
Return to factory settings, except MMSI, MAC address, FACTORY and adjusted values. SETTINGS 3-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 132
78K APP 01.xx.20xxxxxx 0550247-01.xx 78K BOOT 3-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 133
0, 1-- 0, 1-- 0, 1-- 3-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 134
HOOK ON/OFF OFF/ON [LCD TEST] (4/4) 3-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 135
4. POWER ON LOG 5. INFORMATION LOG 3-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 136
SOFTWARE ERASE [for DEVELOP] DEBUG MODE 3-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
DSC- and RT-related system settings and a more 4-49 detailed maintenance menu. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[MENU] -> 9.SERVICE -> 2.DSC SETUP. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
When MMSI is already registered, overwrite the MMSI. To exit this window, press the [CANCEL] key. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Subsequently, a message saying “Initializing…” will appear and the RT window will open. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
TX POWER (USER CH) Call from NBDP Terminal CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
2. Press the [5]: ENTRY key. The “USER CH ENTRY” window will appear. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 143
Repeat the procedure aforementioned to register all other channels. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Click “YES,” and then press the [ENTER] knob. All channels will be deleted. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
“RT” window to reflect the channel selected on the RT window. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
<VIEW> HOST NAME (depending on model) 4-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
1.5-s delay time is provided to close it. 4-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
CLARIFIER is enabled in SSB, CW, and LSB MODE. 4-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[MENU] -> 1.TEST -> 1.DAILY TEST 4-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 150
[MENU] -> 9.SERVICE -> 3.RT SETUP -> 2.SELF CHECK 4-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 151
Sample: Send DISTRESS ALERT Message Sample: Received DISTRESS ALERT Message 4-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
However, GNS sentences from any talker other than GP, GL, GN, and GA are not received. 4-16 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 153
Priorities of formatters: GNS > GGA > RMC > GLL 4-17 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
• IEC: Not allow for the use of RMC time as system time. 4-18 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
NO TIMEOUT. 4-19 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 156
Submenu-1 “8. CW” will be added. 4-20 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
RT SETUP -> 1.SETUP -> “LINE OUT.” The adjustment range is 0 dBm ± 10 dBm/ 600Ω. 4-21 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
RX FIL Fig. 4.3.1 ANT SELECTOR 4-22 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
DDS frequency data of 1st LO on the RX board. 4-23 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
FS-2575C is given the top priority. 4-24 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 161
2 − 3: NORMAL CLOSE Fig. 4.3.2 EXTERNAL ALARM I/F 4-25 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
• FS-2575: SSB004 • FS-5075: SSB005 4-26 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
-> 9. SERVICE -> 2. DSC SETUP -> CLASS, the frequency will be fixed to 2187. 5kHz.” 4-27 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[CANCEL]: BACK Returns to the previous window. 4-28 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[ENTER] knob. 4-29 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[6]: Switched by LIST Key 4-30 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
The content of the address selected will be replaced with that edited. 4-31 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Indicates that data has come from the address book. 4-32 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
“TO” data entry column. [DSC MSG]: COMPOSE 4-33 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[ENTER] knob. With this, the registration of a single MESSAGE FILE is completed. 4-34 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Click “YES,” and then press the [ENTER] knob. All message files will be cleared. 4-35 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
To transmit this message, click on “GO TO CALL,” and then press the [ENTER] knob. 4-36 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
ITU-R MANUAL M.493-11. 4-37 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 174
[TAB] key. 4-38 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
CIRCLE or QUADRANT. 4-39 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Turning the [ENTER] knob allows for the selection of scanning frequency being stopped. 4-40 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
DSC Distress and Safety frequency to the scanning frequency of ROUTINE Scan table. 4-41 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 178
HOOK SP. Enter “652111.” Select to “DISTRESS.” 4-42 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
75 dBA to 85 dBA at a distance of 1 meter from a sound source. 4-43 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
For details, refer to information on page 4-42. 4-44 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
ON/OFF setting of external alarm sound output. 4-45 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
MSG after LOG. receiving DIS 4-46 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 183
500NM. 4-47 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
For details, refer to information on page 6-20. 4-48 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Subsequently, select on “9. SERVICE,” and then enter the password: XXXXXX. Enter the password. Spanner Mark 4-49 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
4-83 to 4-86 SOFTWARE ERASE DEBUG MODE 4-50 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 187
If this function gets activated, a popup message saying “CH BUSY!” will be outputted. 4-51 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Do not make unnecessary changes to the alarm sound level setting. 4-52 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
MF, MF/HF Mode: Main Menu NON-GMDSS Mode: Main Menu 4-53 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 190
MMSI information will be put into a nonregistered state. 4-54 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 191
“Unread icon” on the window. 4-55 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 192
[RADIO TELEPHONE] is displayed in place. RADIO TELEPHONE RADIO TELEPHONE 4-56 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 193
Disables the [DISTRESS] key not to allow for the transmission of Distress alerts. 4-57 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 194
4-58 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
(Expanded DSC message) IEC61162-1 port: Betwseen TB6 #1-2 4-59 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
4 seconds, enter the password: XXXXXX, and then click on “CLEAR ALL.” 4-60 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
(Except limit frequency) MARINE/USER ITU/USER USER 4-61 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 198
16806.5 (MSI-HF) 19680.5 (MSI-HF) 22376.0 (MSI-HF) 26100.5(MSI-HF) 4-62 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 199
For distress and Safety communications! [CANCEL]: Close window 4-63 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 200
4125.0 1200 12290.0 6215.0 1600 16420.0 4-64 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
CALL frequency of “H2B/2331.5 kHz” will be allowed. 4-65 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Setting LSB to “ENABLE” will add a submenu “LSB” on the MODE popup window on the RT window. 4-66 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
#13: LINE_IN _C #14: REM_TX KEY_N #7: GND 4-67 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
For the set value of the clarifier, DDS frequency data of 1st Lo on the RX board is changed and displayed. 4-68 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Connect a jumper cable between #7-#9 of TB6 4-69 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
1.2 MHz away from the transmission frequencies. 4-70 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
RX GND RX GND Fig. 4.7.3 4-71 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 208
RX GND RX GND Fig. 4.7.7 4-72 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 209
[MENU] -> 9.SERVICE -> 4.RT SETUP -> 1.SETUP -> DIVIDER -> ON 4-73 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 210
[MENU] -> 9.SERVICE -> 4.RT SETUP -> 1.SETUP -> DIVIDER -> ON 4-74 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 211
[MENU] -> 9.SERVICE -> 4.RT SETUP -> 1.SETUP -> DIVIDER -> ON 4-75 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 212
DUP FIL board is incorporated, RX ANT is set to “ON” and DUP is set to “CH.” 4-76 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 213
DUP FIL board is incorporated, RX ANT is set to “ON” and DUP is set to “CH.” 4-77 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 214
DUP FIL board is incorporated, RX ANT is set to “ON” and DUP is set to “CH.” 4-78 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
4-79 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
CHI04001) 0=SIMPLEX, 1=SEMI-DUPLEX, DUP MODE 2=FULL-DUPLEX 4-80 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 217
-> [REMOTE] - #21/#22(TD-A/B), #23/ #24(RD-A/B) 4-81 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
For details, refer to information on page 6-42. 4-82 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Distress Alert button on the IC-350. A distress alert reception alarm is also outputted. 4-83 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 220
NAVTEX SEL N.C. (NX-700) N.O. (NX-500) VERCHK 4-84 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 221
FS-xx70 J204 J203 J205 FS-xx70 FS-xx75 4-85 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
This mode is used by R & D and displays debug information, mainly a TIMEOUT counter. 4-86 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 4.8.1 WR2 Cable Connection -1 4-87 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 4.8.2 WR2 Cable Connection -2 4-88 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 4.8.3 WR2 Cable Connection -3 4-89 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
J3: [ACTIVE] 1-2: Active (+12V) 2-3: Wire 4-90 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 4.10.1 EXTERNAL ALARM I/F Circuit 4-91 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
To RX p.c.b -> J2: ANT RX 4-92 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 229
Fig. 4.12.1 AT-5075 Jumper Setting Circuit 4-93 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 230
Fig. 4.12.3 Connection between FS-2570 and AT-5075 4-94 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 231
Fig. 4.13.1 AT-1575 Jumper Setting Circuit 4-95 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 4.13.2 Connection between FS-1570 and AT-1575 4-96 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Enter the changed password in capital letter. (in “caps lock” mode). 4-97 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
9. Select ID Entry (9 digit) 4-98 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 235
The registered answerback code will be deleted. Re-register the answerback code following the procedure specified above. 4-99 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 236
The registered ID number will be deleted. Re-register the ID number following the procedure specified above. 4-100 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
It can be arbitrarily set in the range of 0 to 50 msec, but leave the setting as default. “8 msec” 4-101 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 238
Cyan L-Magenta L-White Magenta Yellow Brown 4-102 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
(according to the shift code Russian received). 4-103 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
3) Hold down the [Shift] key and press the [↓] key. 4-104 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
3) Hold down the [Alt] and [Fn] keys and press the [F1] key. Detailed version will be displayed. 4-105 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
0: Go to Line Format A: Change Text 4-106 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
To incorporate the set value saved to the SD card in the IB-585, execute “Import Settings.” 4-107 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
8: Select ID Entry (9 digit) 4-108 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 245
The registered answerback code will be deleted. Re-register the answerback code following the procedure specified above. 4-109 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 246
The registered ID number will be deleted. Re-register the ID number following the procedure specified above. 4-110 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
To return the “System” setting to the factory set, put the cursor on [Default], and then press the [Enter] key. 4-111 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 248
• Abort: Termination the line upon forced end due to the operation of the control unit. 4-112 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 249
Combinations with the same foreground and background colors are not allowed. 4-113 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Import Settings Error Count Disp None 4-114 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 251
Do not edit the file. Editing the file with incorrect data will disable normal operation. 4-115 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
SD card are allowed. 4-116 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
“ABC-- YZ123---890-?().,’=/+ABCD----UVW” 4-117 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Hold down the [Alt] and [F11] keys to display the version information for developers. 4-118 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
SD Card Text B: New Macro 4-119 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 4.16.1 PR-850A Input Power Supply Voltage 4-120 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 257
Fig. 4.16.2 PR-300 Input Voltage Setting 4-121 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
SEL CALL power data. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 259
6MHz–25MHz 25MHz-27MHz 27MHz-30MHz TUNE PWR SEL CALL CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 260
FS-5075 system in the MF band is 400W+0/−1.5dB. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
● : 4.2MHz, 1500Hz 1-toneMOD. : 4.2MHz, 1100/1700Hz 2-tone MOD. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
● : 4.2MHz, 1500Hz 1-tone MOD. : 4.2MHz, 1100/1700Hz 2-tone MOD. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
● : 4.2MHz, 1500Hz 1-tone MOD. : 4.2MHz, 1100/1700Hz 2-tone MOD. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
● : 4.2MHz, 1500Hz 1-tone MOD. : 4.2MHz, 1100/1700Hz 2-tone MOD. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
● : 4.2MHz, 1500Hz 1-tone MOD. △: 4.2MHz, 1100/1700Hz 2-tone MOD. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
● : 4.2MHz, 1500Hz 1-tone MOD. △: 4.2MHz, 1100/1700Hz 2-tone MOD. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
MIC INPUT ●: 4.2MHz, 1500Hz 1-tone MOD. 5-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
3. Read “Peak envelope voltage-1: E1” in the said state on the oscilloscope. 5-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Continue this measurement until the TX output power becomes saturated. 5-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 270
Since both test tones are set to a specified modulation level, the system facilitates the measurement of TX output power. 5-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Be sure to restore the setup upon completion of adjustment. TB6 #7-#9 Jumper 5-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Selects an output reduction setting level. LOW1 LOW2 5-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 273
Return to Step 3 of this procedure for setting any other mode or frequency band. 5-16 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
2. The “TX POWER (FREQ)” window will appear. Appears in case of FS-5075 5-17 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 275
“HIGH,” and then press the [ENTER] knob. 5-18 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 276
The default of TX POWER (USER CH) means power data set with TX POWER (FREQ). 5-19 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
POWER ADJ” popup window will appear and display the current set power data. 5-20 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
0 ± 10 dBm. 5-21 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 279
[ENTER] knob. SEL CALL power data will return to the default. 5-22 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 5.3.1 Output Power Measurement circuit-1 5-23 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 5.3.2 Output Power Measurement circuit-2 5-24 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Then, adjust power data so that PA Ic will come to 11.9A. 5-25 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 5.4.1 Frequency Measurement Circuit 5-26 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
“5.6 TONE TEST” on page 5-32. 5-27 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 285
CW output frequency = Set TX frequency 5-28 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
“within ±10 Hz,” and then press the [ENTER] knob. 5-29 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 287
Fig. 5.4.2 Example of REF OSC Characteristics 5-30 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
TONE. To make TONE frequency measurement, use the Sub-menu “TX POWER (FREQ).” 5-31 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
This allows for ensuring the setting of tone frequency. 5-32 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
FS-2575 PA Board Arrangement Fig. 5.7.1 PA Board Arrangement 5-33 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 291
Fig. 5.7.3 FS-1575 PA Board (05P0868) 5-34 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 5.7.5 FS-2575: Example of Ammeter Connection 5-35 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
VC reading displayed on the “RT SETUP” window of the FS-5075 is “VC1.” 5-36 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 5.7.7 PA IC Reading Adjustment Circuit 5-37 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 295
Fig. 5.7.8 FS-2575: Example of PA IC Reading Characteristics 5-38 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
BIAS current: 75 mV/0.5 Ω = 150 mA 5-39 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
FS-5075 DRV Board Arrangement Fig. 5.7.10 DRV Board Arrangement 5-40 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
3. Turn ON the power supply, and then press the PTT on the handset to put the system into a TX state. 5-41 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 299
2. Turn ON the power supply, and then press the PTT on the handset to put the system into a TX state. 5-42 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 300
Fig. 5.7.13 DRV Board: Q4-Q5 BIAS Circuit 5-43 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 301
Fig. 5.7.14 DRV Board: Q2-Q3 BIAS Circuit 5-44 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 5.7.15 DRV Board: Q1 BIAS Circuit 5-45 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 5.7.17 REF OSC Block Diagram 5-46 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 5.7.18 Relationship between ALC and TX GAIN 5-47 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 305
8. Set AF GEN output to “1500 Hz/-36 dBm/600 ohms”, and start transmitting (PTT ON). 5-48 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 306
Fig. 5.7.20 TX FIL Board and TX Board 5-49 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 5.7.22 TX FIL Board (05P0876): FS-1575 5-50 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 308
“R43” ALC variable resistor on the TX FIL board. 5-51 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 309
Fig. 5.7.24 ALC Control Circuit Diagram 5-52 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
R3: VS Adjustment Fig. 5.7.25 PA-IF Board 5-53 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 5.7.27 Example of IA Reading Characteristics 10.0A 5-54 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
AF signal output power will no longer increase. 5-55 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[MENU] -> 9.SERVICE -> 3.RT SETUP -> 1.SETUP -> DIVIDER 5-56 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[MENU] -> 9.SERVICE -> 3.RT SETUP -> 1.SETUP -> DIVIDER 5-57 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
• SSG output: F+1kHz R.ANT DUP 15dBuV 5-58 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
COMB board (for FS-5075) and the type of PA-IF board (05P0864 for FS-2575/5075 05P0864A for FS-1575) in combination. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
-> 1.VERSION. For details, refer to information on page 6-23. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
1st MIX circuit is not checked. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
45MHz Fig. 6.1.3 WR2 Test Circuit Diagram CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 6.1.4 ALARM UNIT Test Circuit Diagram CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
✔ ✔ ✔ COUPLER ✔ ✔ ✔ CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
ON” and “PA ON” signals turn ON the BIAS circuit of the DRV and PA boards. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 323
Fig. 6.1.6 Signals Detected by TX SELF TEST CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 6.1.8 TX PLL CHK Circuit Diagram CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 325
Fig. 6.1.9 TX RF CHK Circuit Diagram 6-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
OK when the detected level is not lower than a specified level. 6-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 6.1.11 PA CHK Circuit Diagram 6-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 6.1.12 COMB Board Block Diagram 6-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 6.1.14 COUP CHK Circuit Diagram 6-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Min. 40 (0.032V) 99 (0.08V) 99(0.08V) 6-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 331
Example of FS-1575 SELF CHECK Results 6-16 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
°C = {(V × 1000) − 424}/6.25 6-17 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
°C = {(V × 1000) − 424}/6.25 6-18 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
For details, refer to information on page 6-14. 6-19 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
If the PLL circuit of any of the TX, RX, WR1, and WR2 boards becomes unlocked, replace the TX board. 6-20 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
** FS-2575C: Individually back up the set value. ** 6-21 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
For details, refer to information on page 4-4. 6-22 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Displays program version. Displays board version. 6-23 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 339
Note) Displays updated version and date. Example: 01.03.20110805 6-24 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 340
BOOT program to be updated is the starter program. Note) 0550247-xx.xx 6-25 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 341
SH-2A CPU to the 78K CPU. The following window shows a program in the process of updating. 6-26 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 6.5.1 Version Verification Circuit Diagram for FS-5075 6-27 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
This signal is not in use. 6-28 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 344
Fig. 6.5.3 INST Signal of COMB / PA-IF Board 6-29 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 345
The output port is #1 to #2 (TD A/B) of TB6 on the T-IF board. 6-30 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
For details, refer to information on page 6-27. 6-31 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
C-CPU board. The column displays the results of Read/Write tests, respectively. 6-32 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Pressing the [ENTER] knob will switch the display to the (2/4) window and automatically conduct LED tests. 6-33 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
• BUSY ERROR ! : Printer line is OFF. 6-34 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Pressing the KEY will turn the key display in question from black to blue. 6-35 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Then, press the [MENU] key twice to exit from the C-CPU test mode. 6-36 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 6.5.4 CONTACT SIG and LOOP BACK Signal Circuit Diagram 6-37 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
To stop printing, click on “STOP.” 6-38 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
• Between #4 (IC TD-B) and #6 (IC RD-B) of TB7 6-39 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
“0” to “17.” 6-40 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Every time the [3] key is pressed, the LCD window changes to “White” -> “Black” -> “Previous window.” 6-41 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
For details, refer to information on page 4-80. 6-42 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
• SHIP’S MAIN FAILURE • VC ERROR 6-43 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
6-44 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
T-CPU board whether they have any error in operation. When an error is detected, the system will restart. 6-45 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
• CLEAR ALL (Set “S1” on the T-IF board to “ON,” and then enter the password.) 6-46 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
NIGHT MODE, DAY MODE LED & LCD Day mode: Max. setting mode 6-47 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 363
“INITIALIZING…” window. This state continues for a while. 6-48 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 364
“SOFTWARE ERASE,” this will not be recorded in the software update log. 6-49 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
3. FPGA LED CR14 CR9, 11 6-50 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Turns ON when CPLD is in operation (when power supply turns ON). 6-51 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
FPGA LED Normally turns OFF. 6-52 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
・While the application program is running: Blinks slow. 6-53 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
CR10 (RUN) [TUNE], [CHECK] AT-5075 AT-1575 6-54 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
(in 100-msec period). 6-55 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Checking cables Checking leads Fixing components 6-56 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
The copper band should be as short as possible. 6-57 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Antenna coupler or RT breakdown. 6-58 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
8) change the length of the antenna lead-in wire. 6-59 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Antenna Coupler unit 05P0875 AT-5075 COUP 05P0883 AT-1575 6-60 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Flat Cable T-CPU Board Flat Cable 6-61 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 377
Not displaying VC error popup message 6-62 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Board Mounting Guide Pin Guide Hole for Board Connector 6-63 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
80deg. Flat Cable 6-64 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
6-65 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
FS-2575T- Heat Sink Side FS-1575T- Heat Sink Side 6-66 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 382
FS-5075: 05P0867A FS-2575: 05P0867B FS-1575: 05P0868 6-67 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 383
4) COMB board (FS-5075: 05P0869) 5) FET board (FS-5075: 05P0872) 6-68 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
TX FIL board. For the adjustment procedure, refer to information on page 5-50. 6-69 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
9. DUP-FIL board: 05P0863 (FS-5075) No setting is required. 6-70 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
2) Set the “S2” DIP switch all to “OFF.” DIP SW: S2 (ALL OFF) 6-71 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
2) Set the “S2” DIP switch all to “OFF.” DIP SW: S2 (ALL OFF) 6-72 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
For details, refer to information on page 4-93. AT-5075 AT-1575 6-73 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
“WR1, 2 PLL UNLOCK” will be outputted. 6-74 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Q4, 5: SD1407 Drain: 15.0 VDC 6-75 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 391
Fig. 6.11.2 FS-5075 DRV Board - Example of CHK DA, VR DA vs. Power Characteristics 6-76 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 392
Fig. 6.11.4 Power Check Using DRV Board Alone 6-77 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 6.11.5 FS-2575 and -5075 - PA Board Block Diagram 6-78 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 394
Fig. 6.11.7 FS-2575 PA Board - Example of CHK PA, VR PA vs. Power Characteristics 6-79 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 395
Fig. 6.11.8 FS-2575 and -5075 - Power Check Using DRV Board plus PA Board Alone 6-80 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 6.11.9 FS-1575 - PA Board Block Diagram 6-81 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 397
Fig. 6.11.11 FS-1575 - Power Check Using PA Board Alone 6-82 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 6.11.12 FS-5075 - COMB Board Block Diagram 6-83 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 6.11.14 FS-5075 TX FIL Board - Example of CHK IN VR, ALC vs. Power Characteristics 6-84 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 400
Fig. 6.11.16 FS-1575 TX FIL Board - Example of CHK IN VR, ALC vs. Power Characteristics 6-85 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
RX antenna or shared use of T/R antenna CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.1.2 Configuration of FS-5075T Transceiver Unit CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.1.3 Configuration of FS-2575T Transceiver Unit CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.1.4 Configuration of FS-1575T Transceiver Unit CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.1.5 Configuration of FS-2575C Control Unit CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
FS-1575 05P0870A/B, but different in power capacity. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 407
CODEC, ADC, FPGA, and DSP. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Provides the same function as above. 05P0883 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Lo frequency in the 2nd Mixer circuit. Furthermore, this TX board controls TX output power. The TX board outputs power to the PA board in case of the FS-1575 system and to the DRV board in case of FS-2575 and FS-5075 systems.
Fig. 7.2.2 SSB TX IF Input vs. Board Output Power Level 7-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
• USB: +1.5 kHz ・H3E, CW, TLX: 0 kHz 7-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
4. TX output power control circuit 7-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 413
7.2 Transmission Circuit 7-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 414
7.2 Transmission Circuit 7-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 415
Fig. 7.2.5 Example of FS-2575 Power Control Input vs. Output 7-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 416
Reference above. 7-16 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 417
And for the power reduction control. 7-17 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[MENU] -> 9.SERVICE -> 5.TEST -> 1.VERSION. 7-18 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.2.7 DRV Board Block Diagram 7-19 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 420
Fig. 7.2.8 Example of DRV Board Frequency Characteristics 7-20 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
150 mA TP1 - TP2: 75 mV 7-21 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.2.9 FS-2575/FS-5075 PA Board Block Diagram 7-22 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 423
Fig. 7.2.10 Example of PA Board Frequency Characteristics Frequency Characteristics 7-23 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
DRV boards remains at the threshold for a period of one minute or longer. 7-24 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 425
Fig. 7.2.12 FS-1575 PA Board Block Diagram 7-25 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
77°C or above 84°C or above 7-26 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
PA IC. 7-27 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.2.13 COMB Board Block Diagram 7-28 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.2.14 TX FIL Board Block Diagram 7-29 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
8M: PA OUT 8M: TX FILOUT 7-30 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
0dB line 4.5-6.6M LPF 3.2-4.5M LPF 7-31 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 432
0dB line 14-20M LPF 20-27M LPF 7-32 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.2.15 PA-IF Board (05P0864) Block Diagram 7-33 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 434
UN_BAL PA of the COMB board 7-34 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
05P0864 FS-5075 Not mounted Mounted 05P0864 7-35 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.2.17 PROTECT Signal Circuit Diagram 7-36 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.3.1 RX FIL Board Block Diagram 7-37 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
BAND-1: 100 to 1449.9 kHz BAND-3: 5000 to 7999.9 kHz 7-38 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
PRESEL: 2200 to 2249.9 kHz PRESEL: 4200 to 4549.9 kHz 7-39 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Output: DIV OUT1 Example of DIV Amplifier Characteristics 7-40 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 441
Fig. 7.3.3 Example of Receiving Antenna Divider Installation Pattern 7-41 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.3.4 Example of Installation Pattern for Duplex Specification 7-42 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 443
DUP-FIL Characteristics Tx B.W RX B.W 7-43 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 444
25M DUP FIL/Span 4MHz 22M DUP FIL/Span 4MHz 7-44 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
54 MHz 2nd IF 36 kHz 7-45 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.3.7 Example of 36-kHz RX IF Signal Input vs. Output Characteristics 7-46 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
However, even if the RF ATT automatically turns ON, “ATT” will not appear on the RT window. 7-47 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[MENU] -> 9.SERVICE -> 5.TEST -> 1.VERSION. 7-48 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 449
Fig. 7.3.11 AF OUTPUT Characteristics Fig. 7.3.12 S Meter Characteristics 7-49 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.4.1 WR Board Block Diagram 7-50 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
RF FIL 2 18-MHz LPF 30-MHz LPF 7-51 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
50 to 55dBm in reverse gain mode. This is the level that TP-1 voltage falls from 3.5V. 7-52 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
“J3” of the WR boards to the “active” side, and then supply 12V power to the FAX-5 pre-amplifier. 7-53 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.5.1 T-IF Board Block Diagram 7-54 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.5.2 MOT Board Block Diagram 7-55 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 456
Fig. 7.6.1 T-CPU Board (05P0859) Block Diagram 7-56 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.6.3 Overview of Transmission Processing Circuit within DSP Transmitter 7-57 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 458
Fig. 7.6.5 Overview of Received DSC/NBDP Signal Processing within DSP 7-58 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.6.7 Overview Diagram of Received Voice Signal Channel 7-59 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.6.9 Overview Diagram of NBDP RX IF Signal Channel 7-60 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.6.11 Overview Diagram of WR1 IF Signal Channel 7-61 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.6.12 Overview Diagram of WR2 Signal Channel 7-62 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
NB set to ON in SSB Mode 7-63 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
SSB mode in SSB mode 7-64 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
78K CPU when turning ON the power supply. 7-65 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
• Configuration of command packet Model name+Source+Destination+Command+Voice data (80 bytes) 7-66 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
REG board has a built-in overcurrent (19A) protection circuit. 7-67 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.7.1 FS-5075 Power Supply Circuit Block Diagram 7-68 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.7.3 FS-1575 Power Supply Circuit Block Diagram 7-69 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
J110 Fig. 7.8.1 FS-2575C Block Diagram 7-70 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
For details, refer to information on page 6-47. 7-71 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.9.1 COUP Board (05P0875) Block Diagram 7-72 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
FS-2575C unit. Not used for the matching procedure. 7-73 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 474
7-74 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
The voltage is given as: 7-75 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
4) Upon completion of the self-test, the system will return to the original state. 7-76 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Ci: 0 L: 15 Co: 10 7-77 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 478
Ci: 1 L: 8 Co: 20 7-78 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 479
VSWR= 1.747(365 99) IA= 17 Ci: 0 L:25 Co: 30 7-79 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 480
Ci: 9 L: 9 Co: 30 7-80 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 481
Ci: 0 L: 19 Co: 40 set_memory tune_ok time=8208[ms] turn=145 7-81 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 482
Ci: 53 L: 291 Co: 0 7-82 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 483
Ci: 91 L: 280 Co: 0 7-83 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 484
Ci: 76 L: 288 Co: 0 7-84 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 485
Ci: 0 L: 747 Co: 0 7-85 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 486
Ci: 62 L: 612 Co: 4 7-86 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 487
ADC VF=0 VR=0 HOT=539 IA=0 turn:5554 > thresh:1644*2 trace_mode on 7-87 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 488
L: 679 [SKIP]) IA= 17 Ci: 0 L: 10 Co: 20 7-88 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 489
Ci: 46 L: 420 Co: 8 CHARENGE_CO:30 7-89 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 490
Ci: 62 L: 375 Co: 8 7-90 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 491
Ci: 0 L: 688 Co: 4 set_memory tune_ok time=15824[ms] turn=302 7-91 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.9.5 Table of Gamma-matching Constants 7-92 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 493
Fig. 7.9.7 Table of Loading Coil Constants 7-93 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.9.9 Pi-matching Measurement Constant for 50-ohm Loads 7-94 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
RESET Fig. 7.10.1 TERMCPU Block Diagram 7-95 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 496
Incompatible PWR C 16P0214A 16P0214A Compatible 7-96 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
(Protection circuit activated at 14.2A. Overcurrent detected with R33) 7-97 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 498
• Keyboard connection (U7): Connect the keyboard (PS/2) • FDD (U7): 2HD compatible 7-98 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
• Timer OP • System data 7-99 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Fig. 7.10.5 PWR Board Block Diagram 7-100 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
The program version and date (e.g. 01.00 20110902) of the C-CPU program are displayed. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
(2) CPU: Nios2 Fig. 8.1.1 CPU and Memory Configuration CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
To print out daily test results, press the [4] key. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 504
For details, refer to information on page 6-23. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
It takes approximately 8 minutes to update all programs aforementioned. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 506
PC according to the set network address. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 507
ON the power of this unit as well. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 508
[CANCEL] key to clear the message. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 509
Then, press the [ENTER] key on the PC. The Command Prompt window will disappear. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 510
APP, BOOT, and FPGA in the [FS-2575C] column of this menu. 8-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 511
RT window. 8-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
RT window. 8-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Displays the results of communication tests with the printer. 8-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
7. Turn OFF the power once to reset the system. 8-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 515
9. Turn OFF the power once to reset the system. 8-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
USB Test USB Test alphanumeric characters. 8-16 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
(female) (male) 9 pin D-sub (male) 8-17 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 518
6. Upon completion of the program update, the NBDP window will automatically appear. 8-18 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 519
Verifying Check-SUM. Processing xx% < 0000000000__________________________________________> 8-19 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 520
Program update is CANCELED. Please remove SD-Card reboot. 8-20 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
UPPG.exe LDALL576.BIN FSXX75.BIN 0 0 0 1 1 COM port number 8-21 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 522
The updating procedures for the T-CPU, C-CPU and 78K CPU are the same way. 8-22 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 523
Check the program version number. 8-23 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
You can also register MMSI from the Parameter Browser. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
MMSI or entry of positional data. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[MENU] -> 7.AUDIO -> 5.SIDE TONE and 6.SIDE TONE LV CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
A29. These figures deviate from the threshold for self-checks. There is a problem with the relevant circuit. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
“TR1.” Executing the TUNE will display the matching process. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
25 to 30A (40A) FS-1575(150W) PR-300 (20A) CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
ATU failure. CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[MENU] -> 7.AUDIO -> 2.OFF HOOK -> “SP ON.” CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Distress ACK. Upon receipt of the Distress ACK, the CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
RX-FIL board. 9-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
9-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Coast radio station. 9-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 536
9-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
TX and RX. *1: Not available 9-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Set values will be uploaded onto the FS-xx75 system. AP1-1 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
When you reinstall a General Menu Manager program, delete this program first. AP1-2 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
“P-BROWSER” will be set back to “OFF” when turning ON the power again. AP1-3 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 541
• TCP Port : Set to 10999 AP1-4 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 542
Note) The numbers such as “50800000” is the ID number of parameters internally processed. AP1-5 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 543
[RELOAD] key. AP1-6 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Displays the setting range of a parameter selected. AP1-7 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Menu Tree window will be downloaded in a batch. AP1-8 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
FS-xx75 system and, subsequently, update the contents of the window. AP1-9 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Main window. AP1-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
SYSTEM -> 9.NETWORK -> IP Cont’d ADDRESS. AP1-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 549
FS-xx75 system in an XML format. AP1-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[SET] key. AP1-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
PC. XML File General Menu Manager AP1-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[SET] key for the “Batch Download/Upload” key in NORMAL MODE AP1-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
“Save As”. AP1-16 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[SET] key for the “Batch Download/Upload” key in NORMAL MODE AP1-17 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
The Preview window will appear. Click on the Print key to print out the menu. AP1-18 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
COMB TX_FIL COUPLER =====USER CH================================= =====00-99=================================== AP1-19 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
DAILY TEST RESULT TX SELF TEST RESULT AP1-20 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
General Menu Manager: SERVICE MENU -> MMSI SETUP -> MMSI AP1-21 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 559
5. Reboot the power supply of the FS-xx75 again to ensure that the MMSI setting has been properly made. AP1-22 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
STATUS Display [START] Key AP1-23 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
DAILY TEST/SELF TEST Results window. AP1-24 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
“Version Information.” AP1-25 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[CANCEL] key is pressed. AP2-1 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 564
The condition for stopping this alarm sound is that the [CANCEL] key is pressed. AP2-2 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 565
The condition for stopping this alarm sound is that the [CANCEL] key is pressed. AP2-3 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 566
[CANCEL] key is pressed. AP2-4 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
[CANCEL] key is pressed. AP2-5 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
The condition for stopping this alarm sound is that the [CANCEL] key is pressed. AP2-6 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 569
Ring-back tone is that the [CANCEL] key is pressed. AP2-7 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
AP2-8 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 571
User Option is set to any menu, and then the [ENTER] knob is pressed. AP2-9 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 572
[ENTER] knob is pressed. AP2-10 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 573
The condition for deleting this message is that the [ENTER] knob is pressed. AP2-11 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 574
[CANCEL] key is pressed. AP2-12 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 575
[CANCEL] key is pressed. AP2-13 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 576
[ENTER] knob or [CANCEL] key is pressed with the cursor put on any Option. AP2-14 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 577
[ENTER] knob or [CANCEL] key is pressed with the cursor put on any Option. AP2-15 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
AGC, Noise Blanker, Voice-activated squelch, Noise reduction AP3-1 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
4.5 Alarm volume 80 to 85 dB(A) AP3-2 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
100/110/120/200/220/240 VAC, 1 phase, 50/60 Hz AP3-3 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
N2.5 10.2 Antenna coupler N9.5 (white) AP3-4 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
1. FS-1575 2. FS-2575 3. FS-5075 AP4-1 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 583
5. 1TONE・・1500Hz 2 TONE・・700Hz/1700Hz : N/A AP4-2 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 584
23.5 206.8 31.1 65.0 1TONE (ITU401) AP4-3 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 585
5. 1TONE・・1500Hz 2 TONE・・700Hz/1700Hz : N/A AP4-4 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 586
15.5 41.0 246.0 40.6 1TONE (ITU401) AP4-5 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 587
5. 1TONE・・1500Hz 2 TONE・・700Hz/1700Hz : N/A AP4-6 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 588
22.5 42.1 383.1 28.7 1TONE (ITU401) AP4-7 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
SCHEMATIC DIAGRAM IF-8500 C6503 –K10 S-13 (IF-8500) S0-1 CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Page 598
AC IN 1φ,50/60Hz IV-2sq. AC-DC電源ユニット IV-8sq. *1 *3 AC/DC POWER DPYC-6 24VDC SUPPLY UNIT PR-300 注記 *1)造船所手配。 *2)オプション。 *3)長さに応じて芯線太さを変更する。 DRAWN TITLE FS-1575 T.YAMASAKI *4)内部スイッチ設定が必要。 8/Dec/2011 CHECKED 名称 NOTE SSB送受信機 H.MAKI 8/Dec/2011 *1: SHIPYARD SUPPLY. APPROVED Y.NISHIYAMA 相互結線図 8/Dec/2011 *2: OPTION. SCALE...
Page 605
CONFIDENTIAL (internal use only) This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.