Optional Operation - Furuno FS-1575 Service Manual

Ssb radiotelephone
Hide thumbs Also See for FS-1575:
Table of Contents

Advertisement

Frequency deviation is to be within ±10 Hz on all bands. If DSC or NBDP
5)
communications are not successfully completed, check for frequency deviation. If
the frequency deviation falls within ±50 Hz, messages can be decoded although
error rate surely increases. For the frequency adjustment procedure, refer to
information on page 5-26.

1. Optional Operation

1.1 Registering MMSI and Performing CLEAR ALL (See 4-3)
Press and hold [S1] on the T-IF board for a period of four seconds or more, and then
enter the password: XXXXXX.
1.2 Entering Service menu (See 4-49)
Select [MENU] -> Press [TAB] five times -> Select "9.SERVICE" -> Enter the
password: XXXXXX.
1.3 Entering Network Setting menu (See 4-26)
Enter the password: XXXXXXXXX on the NETWORK <View> window.
1.4 Monitoring DSC reception signal (See 4-40 and 4-41)
Enter the password: XXXXXX on the SCAN window, and then select whether to
monitor ROUTINE or DISTRESS SCAN.
However, note that the ringtone is outputted according to the setting made by
selecting [MENU] -> 7.AUDIO -> 2.OFF HOOK.
1.5 Clearing received Distress log
1) Select [MENU] -> 9.SERVICE -> 4.RESTOE FACTORY SETTINGS.
2) Press and hold [S1] on the T-IF board for a period of four seconds or more, enter
the password: XXXXXX, and then click on "CLEAR ALL."
1.6 Connecting Parameter Browser (See Appendix-1)
1) UserID: N/A, Password: 652111
2) Communication -> LAN Connect Settings -> Connect
3) Main -> Connect Target
Reference)
The password "XXXXXX" is the same as that for the FS-xx70 series.
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Port No.: 10999
2
Summary

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs-2575Fs-5075

Table of Contents