76 | HDZ Series Analogue PTZ User Manual

Enabling/Disabling the Alarm Switch

The ALARM SWITCH field is used to enable or disable the selected alarm pin function. Use the
joystick or left/right direction keys on the control keyboard to change this setting.

Setting the Alarm Type

There are two alarm types: Normally Open (NO) and Normally Close (NC), which are illustrated
in
Figure
corresponds with the alarm application you have connected.
Normally Open Alarm
Normal

Selecting the Alarm Action

Select the type of action that the HDZ Series Analogue PTZ Dome should execute when the
selected alarm is triggered. The mode options include AUTOPAN, PRESET TOUR, MIMIC
TOUR and PRESET (default). Use the joystick or LEFT/RIGHT direction keys to change the
setting, and the options below will change to correspond with your selection. Additionally, when
an alarm is triggered, there will be a flash warning notice, ALARM, displayed in the upper right
corner of the screen.
Selecting a Preset Point
PRESET must be selected as the ALARM ACTION for this option to be available (see
the Alarm Action on page
after the selected alarm is triggered. The preset point(s) should be setup in the PRESET setup
menu or through the keyboard prior to using with the Alarm function (see
Position on page 65
www.honeywell.com/security
Note
If two or more alarm pins are triggered at the same time, the smaller alarm pin
number will have higher priority and be handled while other alarms are ignored
(see
Setting the Alarm Priority on page
are triggered simultaneously, only Alarm-1 will actually be handled.
4-25. Use the joystick or left/right direction keys to select an alarm type that
Figure 4-25
Examples of Alarm Types
Alarm
Note
When dwell time (setting: 1~127 seconds, or ALWAYS) has elapsed, the HDZ
Series camera will go back to the previous status before the alarm was triggered.
76). Select a preset point where the Analogue PTZ Dome should go
for more information on setting up preset points).
77). For example, if Alarm-1 and Alarm-3
Normally Close Alarm
Normal
Alarm
Setting Up a Preset