Nac Hi-Moiton II Quick Manual page 8

3-chip high definition high speed camera system
Table of Contents

Advertisement

4.2
Front Panel
A
POWER
1
MAIN
2
HEAD
B
CABLE Indicator
1
OPTICAL LEVEL
○●●●
・ ○●●○ 2.ATTENTION Cleaning recommended, but still usable
・ ○●○○ 3.WARNING
・ ●○○○ 4.NG
2
CAMERA CABLE
・ ●NORMAL
・ ●OPEN
・ ●SHORT
C
MIC
1
ON
2
OFF
3
PTT
D
INCOM
1
PRIV
2
COMM
E
REMOTE / LOCAL
Please set to LOCAL. REMOTE is inactive.
F
FAN ALARM
The indicator lights on when CCU fan stops.
Power switch of CCU
Power switch of Camera Head
Status of Optical communication of camera cable
1.OK
The cable is in good condition
Problem in communication. Must clean the cable
Not usable. Change the cable.
Status of camera cable
Status is normal.
The cable may be disconnected or snapped
The cable may be short-circuited.
Turns ON Sound communication from MIC of CCU front to Camera Head
Turns OFF Sound communication from MIC of CCU front to Camera Head
Turns ON MIC of CCU front only while the switch is at PTT position.
Deactivates Engineer line of INTER COM connector on the rear panel of the CCU.
Activates Engineer line of INTER COM connector on the rear panel of the CCU
8