12 Trouble Shooting

12.1 Possible troubles during system initialization
A
No image output
1
B
Noise on image output. There are three ways to perform trouble shooting.
Try the following three measures.
1
2
3
C
CCU repeats booting
1
2
3
D
Screen Burn-In
1
12.2 Noise from Intercom on CCU
If you hear noise from the Intercom of CCU, check the following setting.
1
2
Reboot Camera and CCU as a whole system.
Press
ABB
button on OCP.
If 1 does not solve the problem, reboot Camera and CCU as a whole system.
If 2 does not solve the problem, change the setting of FRAME RATE、SENSITIVITY、COLOR
TEMP etc. temporarily to see if the problem will be solved, and set it back to the previous
settings if solved.
Disconnect the GENLOCK signal. When the System Format and the GENLOCK signal are not
identical, the system does not boot up correctly when the GENLOCK signal is in. Check both
are identical first as you disconnect the GENLOCK signal after the system is initialized.
At normal mode when the System Format and the GENLOCK signal are identical, the system
does the second BOOTING... because the system first initializes with internal signal and then
initializes with external signal by recognizing GENLOCK signal.
When the Camera System Format is at 1080/50i or 720/59.94p, there will be BOOTING... for
two time after initialization, but this is not a failure. This is because Hi-MotionII first initializes
with 1080/59.94i then changes to the selected format after the system check.
Close the lens iris and press ABB
The lens iris automatically closed by pressing
connected to the Camera.
Turn ON LENS SERIAL I/F on the Camera Head ( MENU (2/2) > LENS SELECT > LENS
SERIAL I / F ).
Turn ON a serial communication switch of a box lens.
button.
ABB
button when the lens cable is properly
55