10.3 Measurement Subsystem

This subsystem programs the measurement capability of the RP Series AC source. To
select the desired phase, use the INST:NSEL command before the measurement command.
Once selected, a phase selection remains in effect until the next INST:NSEL command.
Subsystem Syntax
:MEASure
:VOLTage?
:CURRent?
:AMPLitude
:CREStfactor?
:RANGe
:POWer
[:REAL]?
:APParent?
:PFACtor?
MEASure:VOLTage?
This query returns the AC rms voltage being sourced at the output terminals. Note that the
output relay must be closed or no voltage will be present at the output terminals.
Query Syntax
Parameters
Examples
Returned Parameters
Related Commands
MEASure:CURRent?
This query returns the rms value of the output AC current being sourced at the output
terminals. Note that the output relay must be closed to obtain current flow.
Query Syntax
Parameters
Examples
Returned Parameters
Related Commands
Returns the rms value of voltage
Returns the rms value of current
:MAX?
Returns peak current
:RESet
Reset the peak current measurements
Returns current crest factor
Selects measurement range 0 = High, 1 = Low, 2 = AUTO
Returns real power in Watt
Returns apparent power in VA
Returns power factor
MEASure:VOLTage?
None
MEAS:VOLT?
<NR2>
OUTP 0 1
MEASure:CURRent?
None
MEAS:CURR?
<NR2>
OUTP 0 1
MEAS:CURR:AMPL:MAX?