Ametek 2003RP User And Programming Manual page 13

Ac power source
Table of Contents

Advertisement

Parameter
Load Regulation
External Sense:
Line Regulation:
Settling time:
Distortion (THD
into linear load):
DC Offset voltage:
Output noise:
Temperature
coefficient:
Stability:
(24 hours)
Total Power:
Current per Output Phase
2003RP-AV:
2003RP-HV
Adjustable Limit:
Specification
1
:
± 0.1% of full scale, 16 Hz - 500 Hz
Will compensate for up to 7% of voltage drop up to 2
kHz
± 0.02% of full scale
From start of voltage change from 5.0 V
higher voltage to within 2% of final value:
No load:
Full load:
(16 ms to within 15% of final value)
0.5% typical, 1.0% maximum below 100 Hz
1.0% typical, 2.0% maximum 100 Hz - 2000 Hz
AC coupled transformer output
< 0.1 V
RMS
( 20 kHz to 1 MHz at full load )
± 0.02% of full scale per degree C
± 0.015% of full scale under constant load, line and
temperature
2000 VA maximum at full scale voltage, either range
Volt Range
2003RP:
135
270
115
230
156
312
0.0 to Maximum available RMS current for selected
voltage range. Maximum current is available for
output voltage from 50% to 100% of range. Current
derates below 50% of range setting. See derating
chart.
16 ms
300 ms
typical
A
RMS
5.0
2.5
5.9
2.9
4.3
2.1
or
RMS
A
PEAK
15.0
7.5
17.6
8.8
12.9
6.3