LIMit:VOLTage?
This command queries the maximum voltage the power source will operate at in the high
voltage range. For 2003RP-AV models configured for single voltage range, only one range is
available. In this case, this command will return the value for the only available voltage
range. The presence of a single range configuration can be derived from the limit value
returned. If the voltage limit value is less than 201 volt, the 2003RP is configured for single
voltage range operation. If a value above 200 volt is returned, the 2003RP has a high and a
low voltage range. On dual range configurations, the maximum voltage in the high range is
returned and this value must be even. The low range value is half that of the high range. On
single voltage range units, the value voltage of the only available range is returned and this
value can be odd or even.
Only the Query format of this command is available to the user.
Command Syntax
Parameters
Query Syntax
Returned Parameters

10.8 Display Subsystem

DISPlay:MODE
This command is used to control the right hand side AC source display. The command will
allow the multifunction 7 segment LED display to switch between display of frequency,
current, peak current, power or power factor data.
The encoding for the mode command is as shown in the table below,
Command Syntax
Parameters
*RST Value
Examples
Query Syntax
Returned Parameters
Related Commands
LIMit:VOLTage<NRf>
maximum voltage available in high voltage range [command
protected]
LIMit:VOLTage?
<NR2>
Parameter
Frequency
Current
Peak Current
Power
Power Factor

Table 10-1: Mode Command Encoding

DISPlay:MODE <NR2>
1 | 2 | 3 | 4 | 5
1
DISP:MODE 2
DISPlay:MODE?
<NR1>
none
Value
1
2
3
4
5