Example: Individual Phase Loss Test
The following command sequence will drop the output of phase A only for 10 cycles at 400
Hz.
/* Set up sequence
VOLT 115;FREQ 400
INST:COUP 0
INST:NSEL 1
OUTP 1
OUTP:STAR:STAT 1
OUTP:STAR:PHAS 90
OUTP:DROP 0.025
Output drop status query
The status of a drop in progress can be queried using the query format of the OUTP:DROP
command. This query will return a <Bool> indicating if the output time specified has expired
(0) or the drop is still in progress (1).
Command Syntax
Parameters
*RST Value
Examples
Query Syntax
Returned Parameters
Related Commands
Set output voltage to 115 V at 400 Hz (all phases)
Uncouple output phases
Select phase A
Close output relay
Enable start phase mode
Set start phase angle to 90 degrees on phase A
Drop for 25 ms (10 cycles @ 400 Hz)
OUTPut:DROP <NRf>
<NRf> | none
none
OUTP:DROP 0.001
OUTP:DROP?
0 | 1
OUTP:STAR:STAT
INST:NSEL
OUTP:STAR:PHAS
INST:COUP