Ametek 2003RP User And Programming Manual page 111

Ac power source
Table of Contents

Advertisement

10.10.4
*IDN?
This query requests the source to identify itself. It returns the data in four fields separated by
commas. Note that any installed options such as –AV are not reflected in the *IDN? query
response. The presence of these options that may affect the power source‟s capabilities
must be determined by querying the Limit system. See section 10.7.
Query Syntax
Returned Parameters
Example
The following table shows the series of queries that may be used to detect the presence of a
2003RP or a 2003RP-AV and to determine the frequency range setting of a 2003RP-AV:
Step
Query command
1
*IDN?
2
LIM:VOLT?
For 2003RP-AV models only:
3
LIM:FREQ:LOW?
4
LIM:FREQ:HIGH?
10.10.5
*RCL
This command restores the AC source to a state that was previously stored in memory with a
*SAV command to the specified location. The RP Series offers eight non-volatile memory
locations for storing instrument setups.
Note:
The state of the 7 segment LED display mode and phase selection is not
part of the non-volatile setup registers.
Command Syntax
Parameters
Example
Related Commands
WARNING:
*IDN?
<AARD>
Field
CI
xxxxxx
nnnnnn
Rev. x.x
"CI,2003RP,12345,Rev 1.0"
Response
"CI,2003RP,12345,Rev 1.0"
270
312
230
115
360
400
5000
400
*RCL <NRf>
0 through 7
*RCL 3
*RST
*SAV
Recalling a previously stored state may place hazardous voltages at
the AC source output if the output relay state saved is ON.
Information
Manufacturer
Model number and letter
Serial number or 0
Revision level of firmware
Interpretation
2003RP series unit.
2003RP standard unit
2003RP-HV, dual Vrange.
2003RP-AV, dual Vrange.
2003RP-AV, single Vrange
Standard frequency range
Fixed 400 Hz (?)
Standard frequency range
Fixed 400 Hz