Service; General; Cleaning; Basic Operation - Ametek 2003RP User And Programming Manual

Ac power source
Table of Contents

Advertisement

7

Service

7.1 General

This section describes suggested maintenance and troubleshooting procedures. The
troubleshooting procedure is divided into two sections. The first section deals with basic
operation and connection of the equipment. The second section requires opening the unit
and using the LED indicators and a simple multimeter to troubleshoot the unit down to the
module level. Only a qualified electronic technician should attempt this level of
troubleshooting.

7.2 Cleaning

The exterior of the power source may be cleaned with a cloth dampened with a mild
detergent and wrung out. Disconnect mains power to the source before cleaning. Do not
spray water or other cleaning agents directly on the power source.

7.3 Basic Operation

PARAGRAPH
7.3.1
7.3.2
7.3.3
7.3.4
7.3.5
7.3.6
7.3.7
7.3.8
7.3.1 Poor Output Voltage Accuracy
If the power source exhibits poor programmed voltage accuracy, the following item may be at
fault:
CAUSE
The calibration is incorrect.

Table 7-1: Basic Symptoms

PROBLEM
Poor Output Voltage Accuracy
Poor Output Voltage Regulation
Distorted Output
Unit Shuts Down After 3-5 Seconds
No Output and no lights on front panel
No output but "Display" on front panel is on
Fault Lamp on
Can‟t program AC Power System on GPIB/RS232

Table 7-2: Poor Output Voltage Accuracy

SOLUTION
Calibrate the output.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents