A-8 Setting Levels Diagram
This diagram shows all of the setting levels. To move to the Advanced Function Setting Level and Cali-
bration Level, you must enter passwords. Some parameters are not displayed depending on the protect
level setting and the conditions of use.
Control stops when you move from the Operation Level to the Initial Setting Level.
Manual Control
Level
Used to set the MV
manually.
S Key for at least 1 s
*1
To use a key procedure to move to Manual Control Level, set the Auto/Manual Select Addition parameter to ON and set
the PF Setting parameter to a-m (Auto/Manual).
*2
The No. 1 display will flash when the keys are pressed for 1 s or longer.
Set the PF Setting parameter to pfdp (monitor/setting items).
*3
E5@C Digital Temperature Controllers User's Manual (H174)
Only when Manual Mode was used
just before power OFF
Power ON
Press the O Key
for at least 1 s or
Level changes
the S Key for at
automatically.
least 1 s
Operation Level
Used for SP, alarm
O Key for at
values, and other basic
least 3 s while
settings and monitoring.
a-m is
*2
displayed.
*1
Press the O Key for
*2
at least 3 s
Initial Setting Level
Used to set the input type
and other basic settings.
Release protection and
then enter the password
(−169) for the amoV (Move
to Advanced Setting
Level) parameter.
Advanced Function
Setting Level
Used to set application functions.
Enter the password
(1201) for the Move to
Calibration Level
parameter.
Calibration Level
Protect Level
Press the O + M Keys for
at least 1 s
Used to set protection
for operations.
Adjustment Level
Press the O Key once.
Used to change adjustment
parameters (PID constants,
Press the O Key once.
adjustment sensitivity, etc.).
Press the S Key.
Press the S Key.
Press the O Key
Monitor/Setting
for at least 1 s.
Item Level
Used to display
specified monitor
and setting items.
Press O Key once
Communications
(models with communications only).
Press the O Key once.
Press the O Key for at least 1 s.
A Appendices
Press the O + M
*2
Keys for at least 3 s.
*3
Setting Level
Used to set up
communications.
A - 35
A