A Appendices
Parameters
Characters
c-i
Integral Time (Cooling)
c-d
Derivative Time
(Cooling)
c-db
Dead Band
of-r
Manual Reset Value
hys
Hysteresis (Heating)
chys
Hysteresis (Cooling)
soak
000
Soak Time
wt-b
000
Wait Band
mv-s
000
MV at Stop
mv-e
000
MV at PV Error
sprt
SP Ramp Set Value
sprl
SP Ramp Fall Value
000
ol-h
MV Upper Limit
ol-l
MV Lower Limit
orl
MV Change Rate Limit
000
db
Position Proportional
Dead Band
oc-h
Open/Close Hysteresis
sqrp
Extraction of Square
Root Low-cut Point
000
Work Bit * ON Delay
w1
to
000
Work Bit * OFF Delay
w1
to
000
plcm
Communications
Monitor
*1
This setting is not displayed for heating and cooling control or for floating position-proportional control.
A - 20
Setting (monitor) value
Integral/Derivative Time Unit of 1 s: 0 to 9,999
Integral/Derivative Time Unit of 0.1 s: 0.0 to 999.9
Integral/Derivative Time Unit of 1 s: 0 to 9,999
Integral/Derivative Time Unit of 0.1 s: 0.0 to 999.9
Temperature input: −199.9 to 999.9
Analog input: −19.99 to 99.99
0.0 to 100.0
Temperature input: 0.1 to 999.9
Analog input: 0.01 to 99.99
Temperature input: 0.1 to 999.9
Analog input: 0.01 to 99.99
1 to 9999
Temperature input: OFF or 0.1 to 999.9
Analog input: OFF, 0.01 to 99.99
Standard: −5.0 to 105.0
Heating/cooling: −105.0 to 105.0
Floating position-proportional control or the Direct
Setting of Position-proportional MV parameter set to
OFF: CLOS, HOLD, or OPEN
Close position-proportional control with the Direct
Setting of Position-proportional MV parameter set to
ON: −5.0 to 105.0
Same as the MV at Stop parameter.
OFF, 1 to 9,999
SAME, OFF, or 1 to 9,999
Standard control: MV lower limit + 0.1 to 105.0
Heating/cooling control: 0.0 to 105.0
Close position-proportional control: MV lower limit +
0.1 to 105.0
Standard control: −5.0 to MV upper limit − 0.1
Heating/cooling control: −105.0 to 0.0
Close position-proportional control: −5.0 to MV
upper limit −0.1
0.0 to 100.0
(0.0: MV Change Rate Limit Disabled)
Close position-proportional control: 0.1 to 10.0
Floating position-proportional control: 0.1 to 10.0
0.1 to 20.0
0.0 to 100.0
8on
0 to 999
8of
0 to 999
0 to 9999
Display
Default
233
233.0
40
40.0
0.0
0.00
50.0
1.0
0.10
1.0
0.10
1
off
0.1
,
to
OFF
999.9
off
0.01
,
to
OFF
99.99
0.0
clos
hold
HOLD
,
,
open
0.0
0.0
off
1
,
to
OFF
9999
same
off
,
,
SAME
1
9999
to
100.0
0.0
−100.0
0.0
0.0
4.0
2.0
0.8
0.0
0
0
E5@C Digital Temperature Controllers User's Manual (H174)
Unit
Seconds
Seconds
°C or °F
%FS
%
°C or °F
%FS
°C or °F
%FS
min or h
°C or °F
%FS
%
None
%
%
EU/s,
EU/min,
EU/h
EU/s,
EU/min,
EU/h
%
%
%/s
%
%
%
Seconds
Seconds
ms