6 Parameters
wt-b
• This parameter sets the stable band within which the soak time is measured for the
simple program function.
Function
Temperature input
Setting
Analog input
Related Parameters
See
See
Program Start (Operation Level): Page 6-12
Soak Time Remain (Operation Level): Page 6-13
Soak Time (Adjustment Level): Page 6-31
Program Pattern (Initial Setting Level): Page 6-46
Soak Time Unit (Advanced Function Setting Level): Page 6-80
mV-s
• This parameter sets the MV to use when the RUN/STOP status changes from RUN to
STOP.
Function
Standard control
Setting
Close position-proportional control with the Direct Setting
of Position-proportional MV parameter set to ON
Heating/cooling control
Floating position-proportional control or the Direct Setting
of Position-proportional MV parameter set to OFF
Related Parameters
See
See
RUN/STOP (Operation Level): Page 6-13
MV at Stop and Error Addition (Advanced Function Setting Level): Page 6-71
Close/Floating (Initial Setting Level): Page 6-57
Direct Setting of Position Proportional MV (Advanced Function Setting Level): Page 6-84
6 - 32
000
Wait Band
Setting range
OFF or 0.1 to 999.9
OFF or 0.01 to 99.99
000
MV at Stop
Control method
The Program Pattern parameter must not be set to
OFF.
Unit
°C or °F
%FS
The control must be set to 2-PID control or a
Position-proportional Model must be used.
The MV at Stop and Error Addition parameter must
be ON.
Setting range
−5.0 to 105.0
−105.0 to 105.0
CLOS, HOLD, or
OPEN
E5@C Digital Temperature Controllers User's Manual (H174)
Unit
off
Unit
Default
%
0.0
None
HOLD