96Y Errors - Lexmark MS315 Service Manual

Machine type 4514-335, -530, -539
Hide thumbs Also See for MS315:
Table of Contents

Advertisement

Invalid firmware/controller board service check
Action
Update the firmware.
Note: Contact the next level of support for the correct firmware level.
Does the error remain?

96y errors

96y error messages
Error code
Description
960.xx
RAM Memory Error—RAM soldered on the card is bad
Replace the controller board.
961.xx
RAM Memory Error—optional DRAM is bad
964.xx
Download Emulation Cyclic Redundancy Check (CRC)
Error—checksum failure detected in the emulation
header or emulation file.
RAM memory error service check
Action
Replace the bad memory card.
Does the error remain?
Download emulation cyclic redundancy service check
Action
Step 1
Disable the download emulation, and then program the download
emulation into the firmware card again.
Does the error remain?
Step 2
Replace the firmware card and download the emulation to the new card.
Does the error remain?
Yes
Replace the controller
board. See
board removal" on
page
Action
Go to
"Controller board removal" on page
Go to
"RAM memory error service check" on
page
105.
Go to
"Download emulation cyclic redundancy
service check" on page
Yes
Contact the next level
of support.
Yes
Go to step 2.
Contact the next level
of support.
Diagnostic information
105
No
The problem is solved.
"Controller
187.
105.
No
The problem is solved.
No
The problem is solved.
The problem is solved.
4514
187.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms415M1140+