Printer hardware errors
111 errors
111 error messages
Error code
Description
111.00
Pel clock check failed.
111.01
Downlevel ASIC detected.
111.31
Printhead never delivered HSYNCs.
111.32
Printhead lost HSYNCs.
111.40
Wrong printhead installed
111.50
Open-loop printhead error, open-loop sweep state.
111.51
Open-loop printhead error, open-loop sweep state.
111.52
Open-loop printhead error, check prelim amp state.
111.53
Open-loop printhead error, enable amp Kp state.
111.54
Closed-loop printhead error, amp Kp failed to
converge.
111.55
Closed-loop printhead error while waiting for amp Kp
to converge.
111.56
Closed-loop printhead error, amp Ki failed to
converge.
111.57
Closed-loop printhead error while waiting for amp Ki
to converge.
111.58
Closed-loop printhead error, load scan regs state.
111.59
Closed-loop printhead error, forward and reverse
capture times differ by too much.
Action
Go to
"LSU service check" on page
Diagnostic information
85
4514
86.