Setting the Remote Control

1. Remove the front cover by undoing the small
screw on the rear of the Remote Control.
2. Located above the battery is a row of 8 DIP
switches. Select and record a random combination
of 'ON' and 'OFF' positions for the DIP switches.
This will be the system House Code that enables
all elements of your transmitters to communicate
with the Control Panel.
Important: The House Code for your system should
be changed from the factory default setting.
3. Ensure that the jumper link located immediately
below the House Code DIP switches is fitted in
position for use with this alarm system.
4. Insert the battery under the clip ensuring that the
+v terminal faces upwards away from the PCB.
5. Replace the front cover and fixing screw.
House Code
Dip Switches
Jumper Link
Battery Clip
Battery
Passive Infrared (PIR)
Movement Detectors
PIR Detectors are designed to detect movement in
a protected area by detecting changes in infra-red
radiation levels caused, for example, when a person
moves within or across the devices field of vision.
If movement is detected an alarm signal will be
generated, (if the system and alarm zone is armed).
Note: PIR Detectors will also detect animals, so ensure
that pets are not permitted access to areas fitted with
Passive Infra Red Detectors when the system is armed.
ny number of PIR Detectors can be used with your
system, providing they are all coded with the system
House Code and are mounted within effective radio
range of the Control Panel.
The PIR Detector is powered by a PP3
battery which under normal conditions will have an
expected life in excess of 1 year. When the battery
level drops, with the PIR Detector in normal operation
mode and the battery cover fitted, the LED behind
the detection window will flash. When this occurs
the battery should be replaced as soon as possible.
Choosing a position for the
PIR Detector
The recommended position for a PIR Detector is in
the corner of a room mounted at a height between
2 and 2.5m.
t this height, the PIR Detector will
have a maximum range of up to 12m with a field of
view of 110°.
10
6
2
12
8
4
metres
Side View
More Sensitive
The Position of the PCB inside the PIR Detector can
be set to 5 different positions to adjust the range of
the detection pattern created by the PIR Detector.
Setting the PCB in position 3 will reduce the range to
approximately 9m, with position 1 providing a range of
approximately 6m. The recommended position setting
for the PCB is in position 5.
When considering and deciding upon the mounting
position for the PIR Detector the following points
should be considered to ensure trouble free operation:
1. Do not locate the PIR Detector facing a window or
where it is exposed to or facing direct sunlight. PIR
Detectors are not suitable for use in conservatories.
2. Do not locate the PIR Detector where it is exposed
to ventilators.
11
Top View
2
110°
0
0
Less Sensitive
lkaline
12
10
8
6
4
2
0
2
4
6
8
10
12
metres