Testing The Pir Detectors - Response SA5 E Installation And Operating Instructions Manual

36 zone wirefree alarm system with voice dialler
Table of Contents

Advertisement

7. DIP4 of SW3 is used to set the PIR Detector for
walk test mode, which allows the operation of the
Detector to be checked during installation without
triggering a Full larm.
ON
Walk Test mode
OFF
Normal operation
DIP 4
Mode
of SW3
ON
Walk
Test
OFF
Normal
Position
Note: On initial installation the PIR Detector should
be set into Walk Test mode ready for testing.
8. The PIR Detector incorporates a sensitivity feature
designed to compensate for situations where the
Detector may be affected by environmental
changes, (e.g. insects, air temperature, etc). This
feature is called "Detection Sensitivity" and may be
set to Standard or High Sensitivity.
Note: The higher the sensitivity the less movement
will be necessary before the PIR Detector will
trigger the alarm.
The recommended setting is Standard Sensitivity.
If set to High Sensitivity, in some cases, extreme
environmental problems could cause unattributed
false alarms. If this is experienced it may be necessary
to reset the PIR Detector to Standard Sensitivity.
Set the required detection sensitivity using DIP 5 of
SW3 as follows:
OFF
Standard Sensitivity
ON
High Sensitivity
9. Connect the PP3 lkaline battery to the battery clip.
Note: When the 9V lkaline battery is connected
the LED behind the lens will rapidly flash for
Trigger reaction
on LED
• LED single flash
when movement
detected: implies
the sensor is set to
high sensitivity
• LED flashes three
times and illuminates
once: implies the
sensor is set to low
sensitivity
LED will not light up
(unless the battery in
the PIR is low)
approximately 2-3 minutes until the PIR Detector
has warmed up and stabilized. The LED will then
stop flashing and turn OFF.
10. Check that the PIR Detector PCB is located and set
in the correct position to give the detection zone
pattern required.
To adjust the PCB position, simply slide it up or
down ensuring that the location legs are aligned with
the required position number marked on the board.
11. Refit the PIR Detector to the rear cover by offering
the PIR Detector up to the rear cover and locate
the clips in the top edge into the rear cover. Push
the lower edge of the PIR Detector into place and
refit the fixing screw in the bottom edge of the PIR
Detector to secure in position. Do not over-tighten
the fixing screws as this may damage the casing.

Testing the PIR Detectors

Ensure that the Control Panel is in Test mode.
With the PIR detector set in Test mode (i.e. Dip 4 on
SW3 ON) and mounted in position on the wall, allow
2-3 minutes for the detector to stabilize before
commencing the Walk Test.
1. Use the
and
the menu until 'W LK TEST' is displayed.
Press
to activate Walk Test.
'Walk Test Waiting...' will be displayed.
2. Walk into and move slowly around the protected
area, each time the detector senses movement
the LED behind the lens will flash. In addition,
the Control Panel will beep to indicate that the
alarm signal has been received and the identity
of the zone that the detector is configured for
will be displayed.
13
5
PCB Positions
4
Indicator
3
(positions 1-5)
2
1
PCB Position
Range
1
6m
3
9m
5
12m
buttons to scroll through