3. Do not locate the Detector directly above a heat
source, (e.g. fire, radiator, boiler, etc).
4. Where possible, mount the PIR Detector in the
corner of the room so that the logical path of an
intruder would cut across the fan detection
pattern. PIR Detectors respond more effectively to
movement across the device than to movement
directly towards it.
5. Do not locate the PIR Detector in a position where
it is subject to excessive vibration.
6. Ensure that the position selected for the PIR
Detector is within effective range of the Control
Panel. It is recommended that prior to installation
the Detector is set and tested with the Control
Panel in Walk Test mode to ensure that they are
within effective range.
Note: When the system is rmed, pets should not be
allowed into an area protected by a PIR Detector as
their movement would trigger the PIR Detector and
trigger an alarm.
Note: DO NOT fix the PIR Detector to metalwork or
locate the unit within 1m of metalwork (i.e. radiators,
water pipes, etc) as this could affect the radio range
of the Device.
Installing and configuring the
PIR Movement Detectors
Ensure that the Control Panel is in Test mode.
1. Undo and remove the fixing screw from the
bottom edge of the PIR Detector. Carefully pull the
bottom edge of the Detector away from the rear
cover and then slide down to release the top clips.
2. Carefully drill out the required mounting holes in the
rear cover using a 3mm drill according to whether
the unit is being mounted in a corner or against a
flat wall.
3. Using the rear cover as a template, mark the
positions of the fixing holes on the wall.
4. Fix the rear cover to the wall using the two 18mm
No. 4 screws and 25mm wall plugs, (a 5mm hole
will be required for the wall plugs). Do not over-
tighten the fixing screws as this may distort or
damage the cover.
Note: The wall plugs supplied with the product are
not suitable for plasterboard walls, if mounting the
PIR Detector onto plasterboard use proprietary
wall plugs.
Mounting Hole
Positions
5. When setting Dip Switches to House Code,
hold the PIR Detector 'upside down' as shown
in the diagram below:
Set the House Code for the PIR Detector by setting
DIP switches 1-8 of SW2 to the same ON/OFF
combination as the House Code DIP switches in all
other system devices.
DIP Switches
(SW2 and SW3)
PCB Board
(slides up and
down to adjust
position)
SW2
ON
1
2
3
4
5
6
Set to House Code
6. Set the alarm zone which the Detector will operate
on by setting DIP switches 1-3 of SW3 as follows:
DIP 1
Zone 1
OFF
Zone 2
OFF
Zone 3
OFF
Zone 4
OFF
Zone 5
ON
Zone 6
ON
12
Rear Cover
Fixing Screw
SW3
ON
ECE
ECE
7
8
1
2
3
4
5
Zone
Walk Test
Settings
DIP 2
OFF
OFF
ON
ON
OFF
OFF
Sensitivity
DIP 3
OFF
ON
OFF
ON
OFF
ON