Initial Power-Up
Battery
Main Configuration
Switch (in SIREN
Position)
C.U.
SIREN
Note: When the Solar Siren is viewed as shown above
(Solar panel at top) the DIP switches are 'upside down'.
larm Duration Limit
If required the maximum length of time that the
External Solar Siren will sound for when activated
under an alarm condition may be limited to 3 minutes
using DIP switch 9 as follows:
OFF
3 minute limit
ON
10 minutes or same as programmed
setting on Control Panel.
Beep Disable
The Solar Siren will acknowledge Disarm signals from
the Remote Control by beeping twice. It is possible to
disable the beeps if required by removing the jumper
link P2 on the circuit board.
Siren Disable
If for any reason you need to disable the Siren, remove
jumper link P3 on the circuit board. This will prevent
the Siren from sounding during an alarm condition.
However, the Siren will still beep to acknowledge
Solar Panel
C.U.
SIREN
Siren
Inside view of Solar Siren
Front Cover
Locating Tabs
Receiver
Aerial
DIP Switch
Cover
Printed Circuit
Board Enclosure
LED/Strobe PCB
signals from the Remote Control, (provided the beep
feature is not disabled).
Once you have completed configuring the Solar Siren,
refit the DIP switch cover and replace the three cover
fixing screws. Do not over tighten the screw as this
could damage the thread.

Initial Power-Up of the Solar Siren

1. Connect the 9V PP3 initial power battery to the
battery clip.
Connect the rechargeable battery to the charging
leads. Connect the Red lead to the Red (+) terminal
and the Black lead to the Black (-) terminals.
Note: Once the batteries have been connected, the
Siren will be operational and it is important that the
Solar panel receives sufficient light to maintain the
battery charge. The Siren should not be operated
repeatedly during installation and testing, as this
will rapidly drain the battery. It is recommended
that the Siren be left for at least a day in order to
charge the battery before the system is armed.
17
7.5 Volt DC
Charging Adaptor
Input
Beep Disable Link
P2
P2
P3
P3
Siren Disable Link
P1
P1
Jamming
Detection Link
House Code
DIP Switches 1-8
Alarm Duration
DIP Switch 9