Magnetic Contact Detectors; Installing And Setting The Magnetic Contact Detectors - Response SA5 E Installation And Operating Instructions Manual

36 zone wirefree alarm system with voice dialler
Table of Contents

Advertisement

If necessary adjust the detection range by
changing the mounting position of the PCB
within the PIR housing.
Note: In normal operation, the LED behind the
PIR lens will not flash on movement detection,
(unless the battery is low).
If necessary re-adjust the detection pattern by
changing the mounting position of the PCB within
the PIR housing.
3. Remove the back cover of the PIR detector.
The Control Panel should beep and display
' ccessory Tamper' to show that the detector's
tamper switch has been activated.
4. Press
to return to the top level menu of Test
ESC
Mode.
5. Reconfigure the PIR Detector for normal mode by
setting DIP4 of SW3 to OFF and refit in position
Note: When the detector is fully installed i.e. battery
cover is refitted; the unit will not detect movement
for approximately 2 minutes after each activation.
(This feature is present to conserve battery power and
maximize the battery life).
Magnetic Contact
Detectors
Installing and setting the Magnetic
Contact Detectors
Ensure that the system is in Test mode.
1. Remove the battery cover by sliding and lifting it
off. (DO NOT use a screwdriver to lever off).
2. Remove the battery holder by carefully tilting up
the end and pulling the connector off the printed
circuit board.
3. Mount the Magnetic Contact Detector to the fixed
part of the frame along the opening edge opposite
the hinges using either the double sided adhesive
tape or screws provided.
When fixing the Magnetic Contact Detector with
screws, the top of the Detector is secured with a
keyhole slot over the screw head of the smaller pan
head screw. The bottom is secured using the 12mm
countersunk head screw fitted within the battery
Raised Head Screw
Key-hole Slot Fixing
(underside)
Double Sided Tape
OR Screw Fixing
Connector
Small Counter-sunk
Screw Fixing
(Ensure
back
surfaces
are flush)
Magnet
Cut-out for
Cable Entry
compartment. Carefully drill out the centre of the
fixing screw hole in the battery compartment using
a 3mm drill. Do not over-tighten the fixing screws
as this may distort or damage the casing.
4. Fit the Magnet to the moving part of the door/
window opposite the Magnetic Contact Detector
using the two 15mm fixing screws. Ensuring that
the parallel gap between the Magnet and Detector
is less than 10mm and that the arrow on the
Magnet is pointing towards and aligned with the
mark on the top section of the Detector.
5. If an additional wired Magnetic Contact Detector is
required, this should be wired to the terminal block
provided in the battery compartment. The wired
contact should be connected using two core
(24 WG) wire of maximum length 1.5m.
Important: If an additional wired contact is not
connected, then the jumper link SW2 must be fitted for
the Magnetic Contact Detector to operate correctly.
14
Slide Open and Lift Off
Do Not Use A Screwdriver
Tilt and Remove
Battery Holder
and Insert
Two Batteries
Battery
Detector
Alternative
Mounting
Battery Cover

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents