Battery Monitoring - Response SA5 E Installation And Operating Instructions Manual

36 zone wirefree alarm system with voice dialler
Table of Contents

Advertisement

1. Dial up the system and hang up after two
rings.
2. Redial up the system within 30s, the system
will pickup the phone after 1 ring.
3. Enter the User ccess code as normal.
The following functions may be access via the
remote. The system will acknowledge each signal
with a single long beep.
Press
to initiate RM.
Press
to initiate Part- rm 1.
Press
to initiate Part- rm 2.
Press
to Disarm the system.
Press
to turn the Siren OFF.
Press
to turn the Siren ON.
Press
to Listen-In via the Control Panel
Microphone.
Press
to stop Listen-In
Note: Listen-In will be automatically cancelled
after 5 minutes if not cancelled manually.
Press
to interrogate the system Status. The
status tone will be repeated at 2s intervals for 15
seconds.
One beep
Two beeps
Three beeps
One long beep
Press
to replay nswer-Phone messages.
While replaying a message, press
2 seconds to skip to the end of the message
and hear the next message.
Press
to delete all nswer Phone messages.
Press
to end the session and Hang up the
Control Panel line.
RM
Part- rm (1 or 2)
larm triggered
Disarmed
for

Battery Monitoring

ll system devices continuously monitor their battery
condition. The Control Panel also monitors the battery
condition of all PIR and Magnetic Detectors. If the
battery level of any device drops below acceptable
levels then its low battery indication will be activated.
In addition if any PIR or Magnetic Contact Detector
has a low battery status it will be indicated on the
'LOW B T' LED on the Control Panel.
LED Glowing
LED Flashing
When a low battery indicator is activated the device
will continue to operate normally for up to 2 weeks
(depending on system use). However, the battery for
that device should be replaced as soon as possible.
Note: Before removing the battery cover on any device
to replace the battery, ensure that the system is put
into Test mode to avoid initiating a Full larm condition.
The low battery indication for each system component
is as follows:
Remote Control:
When the Remote Control is operated under low
battery conditions the transmit LED will continue to
flash after the button has been released.
Under normal battery conditions the LED will extinguish
when the button is released.
PIR Movement Detector:
Under low battery conditions the LED behind the
Detector lens will flash when movement is detected to
indicate that the battery needs to be replaced.
Under normal battery conditions the LED does not
illuminate unless the PIR Detector is in Walk Test mode.
Magnetic Contact Detector:
Under low battery conditions, when the Detector is
activated, the transmit LED will be illuminated for
approximately 1 second as the door/window is
opened.
Under normal battery conditions the LED will not
illuminate as the Detector is operated, (unless the
Detector is in Test Mode with the battery cover
removed).
38
Magnetic Contact
PIR