Test
- when the system is armed, any detector on the zone
will generate an entry in the Event-Log without
initiating an alarm condition.
Note:
Personal
ttack, 24-hour Intruder and Fire
modes all operate on a 24 hour basis, (i.e. they are able
to initiate Full larm condition at any time irrespective
of whether the system is rmed or Disarmed).
Default setting: 'Intruder'
Scroll through the menu until '3-2 Z01 Type' is
displayed. The current setting will also be displayed.
To change the setting press
Scroll through available options until the required
setting is displayed.
Press
to save and exit, or
Press
to exit without saving.
ESC
Final Exit Set
If enabled, triggering of any detector on the zone
during the exit-delay will cancel any remaining exit-
delay and cause the system to arm 5 seconds later.
Default setting: OFF
Scroll through the menu until '3-3 Z01 Final Exit Set' is
displayed. The current setting will also be displayed.
To change the setting press
1
Press
to enable the zone's Final Exit Set
facility, or
3
Press
to disable the zone's Final Exit Set
facility.
Chime
This controls whether the Chime facility is available on
the zone.
Default setting: OFF
Scroll through the menu until '3-4 Z01 Chime' is
displayed. The current setting will also be displayed.
To change the setting press
1
Press
to enable the zone's Chime facility, or
3
Press
to disable the zone's Chime facility.
.
.
.
27

Entry Delay

Scroll through the menu until '3-5 ENTRY DEL Y' is
displayed. The current settings will also be displayed.
To change the settings press
On/Off Status
Default setting:
zone 1:
zones 2-10:
Scroll through the menu until '3-5-1 Status' is
displayed. The current setting will also be displayed.
To change the settings press
1
Press
to enable the zone's entry-delay, or
3
Press
to disable the zone's entry-delay.
Delay Period
Default setting: 30 seconds
Scroll through the menu until '3-5-2 Delay Time' is
displayed.
To change the settings press
Enter the required delay period (10 to 250s).
Press
to save and exit, or
Press
to exit without saving.
ESC
Press
to return to top level Zone Setup.
ESC
Part- rm 1
This controls whether the zone is active when Part-
rm 1 is armed.
Default setting: OFF
Scroll through the menu until '3-6 Z01 Part- rm 1' is
displayed. The current setting will also be displayed.
To change the setting press
1
Press
to enable the Zone in Part- rm 1, or
Press
3
to disable the Zone in Part- rm 1.
.
ON
OFF
.
.
.