Stator And Pick-Up Coil; Generator Rotor - Suzuki RG250 Service Manual

Table of Contents

Advertisement

• Install the gaskets
Q)
.
• When securing the
lower
crankcase, tighten the
8-mm bolts and the 6-mm bolts in the ascending
order of numbers assigned to the bolts, tighten-
ing each bolt a little at a time to equalize the
pressure.
Tighten
all the securing bolts to the
specified torque values.
Tightening
torque
6 mm bolt
9-13N'm
10.9 -
1.3 kg·ml
Final
8
mm
bolt
20 -24 N'm
12
.0
-
2.4
kg·ml
STATOR AND PICK-UP COIL
Install the
stator
after 'applying the
thread lock
"1342"
to the securing screws.
99000·32050
Thread lock
" 1342"
GENERATOR ROTOR
Clean
thoroughly both mating surfaces
of the
rotor and crankshaft with cleaning
solvent.
Fit
key
in the key slot on the crankshaft.
• r
nstall
the generator rotor.
Apply
a small quantity of Thread Lock
"'324"
to the threaded parts of crankshaft.
99000·32120
Thread
Lock
"1324"
ENGINE
3·38
,